Quantitative analysis using external standards with a benchtop NMR spectrometer.

Yejin Lee1, Yevgen Matviychuk1, Daniel J Holland2.   

Abstract

This paper investigates the use of benchtop NMR spectrometers for quantitative analysis with external standards. Specifically, it focuses on the measurement of aqueous samples with analyte concentrations ranging from 30 mM to 1.7 M and electrical conductivity of up to 84mScm-1 using a 43 MHz instrument. It is demonstrated that measurements using the PULCON method cannot achieve an average error in quantification of <4% with the benchtop NMR tested here unless the standard and analyte are very similar. Our analysis indicates that this comparatively large error arises from the fixed tuning and matching of the benchtop spectrometer. We confirm that for moderately dilute samples (less than 0.2 M), the integral area of the solvent peak is suitable for use as an internal standard to mitigate this error. Furthermore, a round robin study demonstrates that the second major source of uncertainty in these measurements arises from the manual processing of the spectra by different analysts. Here we propose heuristics for manual baseline and phase correction to reduce this analyst-dependent error to about 3 %. We also demonstrate that semi-automated quantification using qGSD is able to achieve similar accuracy of integration, but with reduced sensitivity to the processing of the operator.
Copyright © 2020 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Benchtop instruments; External standard; Medium-field NMR; Mixture analysis; Quantitative NMR spectroscopy

Year:  2020        PMID: 33007501     DOI: 10.1016/j.jmr.2020.106826

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  3 in total

1.  One-pot synthesis of 2-bromopropionyl esterified cellulose nanofibrils as hydrophobic coating and film.

Authors:  Mengzhe Guo; You-Lo Hsieh
Journal:  RSC Adv       Date:  2022-05-17       Impact factor: 4.036

2.  RotoMate: An open-source, 3D printed autosampler for use with benchtop nuclear magnetic resonance spectrometers.

Authors:  Marco Dyga; Christoph Oppel; Lukas J Gooßen
Journal:  HardwareX       Date:  2021-06-23

3.  Predicting Mandarin Fruit Acceptability: From High-Field to Benchtop NMR Spectroscopy.

Authors:  Ignacio Migues; Fernando Rivas; Guillermo Moyna; Simon D Kelly; Horacio Heinzen
Journal:  Foods       Date:  2022-08-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.