| Literature DB >> 33006301 |
Katrin Claire Leitmeyer1, Laura Espinosa1, Eeva Kaarina Broberg1, Marc Jean Struelens1.
Abstract
BackgroundTimely reporting of microbiology test results is essential for infection management. Automated, machine-to-machine (M2M) reporting of diagnostic and antimicrobial resistance (AMR) data from laboratory information management systems (LIMS) to public health agencies improves timeliness and completeness of communicable disease surveillance.AimWe surveyed microbiology data reporting practices for national surveillance of EU-notifiable diseases in European Union/European Economic Area (EU/EEA) countries in 2018.MethodsEuropean Centre for Disease Prevention and Control (ECDC) National Microbiology and Surveillance Focal Points completed a questionnaire on the modalities and scope of clinical microbiology laboratory data reporting.ResultsComplete data were provided for all 30 EU/EEA countries. Clinical laboratories used a LIMS in 28 countries. LIMS data on EU-notifiable diseases and AMR were M2M-reported to the national level in 14 and nine countries, respectively. In the 14 countries, associated demographic data reported allowed the de-duplication of patient reports. In 13 countries, M2M-reported data were used for cluster detection at the national level. M2M laboratory data reporting had been validated against conventional surveillance methods in six countries, and replaced those in five. Barriers to M2M reporting included lack of information technology support and financial incentives.ConclusionM2M-reported laboratory data were used for national public health surveillance and alert purposes in nearly half of the EU/EEA countries in 2018. Reported data on infectious diseases and AMR varied in extent and disease coverage across countries and laboratories. Improving automated laboratory-based surveillance will depend on financial and regulatory incentives, and harmonisation of health information and communication systems.Entities:
Keywords: antimicrobial resistance; automated data reporting; clinical microbiology testing; communicable diseases; digital surveillance; early-warning; electronic laboratory reporting; public health surveillance
Mesh:
Year: 2020 PMID: 33006301 PMCID: PMC7531069 DOI: 10.2807/1560-7917.ES.2020.25.39.1900591
Source DB: PubMed Journal: Euro Surveill ISSN: 1025-496X
Figure 1Clinical laboratories reporting data by automated machine-to-machine communication to national surveillance databases, 30 EU/EEA countries, December 2018
Figure 2Countries reporting EU-notifiable disease data from clinical diagnostic laboratories to national surveillance databases, by disease and reporting methoda, 30 EU/EEA countries, December 2018
Figure 3Automated reporting of clinical laboratory data (diagnostic and antimicrobial susceptibility testing dataa) to national surveillance databases, 14 EU/EEA countries with automated laboratory-based surveillance capability, December 2018
Figure 4Modes clinical diagnostic laboratories use to report EU priority indicator antimicrobial-resistant pathogensa to national surveillance databases, 14 EU/EEA countries with automated laboratory-based surveillance capability, December 2018
Type of data reported automatically to national surveillance databases, 14 EU/EEA countries with automated laboratory-based surveillance capability, December 2018
| Data type | Number of countries reporting on automated basis |
|---|---|
|
| |
| Type of clinical specimen tested | 13 |
| Type of diagnostic test performed | 10 |
| Number of clinical specimens tested | 6 |
| Number of diagnostic tests performed | 3 |
| Positive diagnostic test results | 12 |
| Quantitative diagnostic test results (e.g. serology results, NAT results) | 6 |
| Negative diagnostic test results | 4 |
|
| |
| Age | 14 |
| Sex | 14 |
| Place of residence | 13 |
|
| |
| Clinical diagnosis | 8 |
| Underlying disease | 4 |
| Treatments | 3 |
| Vaccination status | 7 |
| Date of onset of disease | 9 |
| Community/healthcare-associated disease | 6 |
| Travel history | 9 |
EU/EEA: European Union/European Economic Area; NAT: nucleic acid amplification testing.