Literature DB >> 3300582

Mechanical assistance for cardiogenic shock following cardiac surgery, myocardial infarction, and cardiac transplantation.

G L Zumbro, W R Kitchens, G Shearer, G Harville, L Bailey, R F Galloway.   

Abstract

From January, 1982, to October, 1986, 33 patients were treated with either the Pierce-Donachy prosthetic ventricle or the Bio-Medicus ventricular assist device for cardiogenic shock following a cardiac operation, myocardial infarction, or cardiac transplantation. Twenty-five patients required the assistance for postcardiotomy shock and 8, for a variety of conditions including myocardial infarction shock and myocarditis, and as a bridge to cardiac transplantation. Complications were frequent and usually secondary to prolonged cardiopulmonary bypass. Results were poorest in the group with postcardiotomy shock. Earlier application of an assist device could lead to more frequent survival and avoidance of the detrimental effects of prolonged extracorporeal circulation.

Entities:  

Mesh:

Year:  1987        PMID: 3300582     DOI: 10.1016/s0003-4975(10)62344-2

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  6 in total

Review 1.  Percutaneous left ventricular assist devices during cardiogenic shock and high-risk percutaneous coronary interventions.

Authors:  Stéphane Cook; Stephan Windecker
Journal:  Curr Cardiol Rep       Date:  2009-09       Impact factor: 2.931

2.  Experimental videothoracoscopic cannulation of the left atrial appendix. A feasible rapid approach for initiating left heart bypass?

Authors:  P F Gründeman; D W Meijer; J J Bannenberg; R Tukkie; P J Klopper
Journal:  Surg Endosc       Date:  1993 Nov-Dec       Impact factor: 4.584

Review 3.  Percutaneous ventricular assist devices for cardiogenic shock.

Authors:  Stéphane Cook; Stephan Windecker
Journal:  Curr Heart Fail Rep       Date:  2008-09

4.  Percutaneous ventricular assist devices: new deus ex machina?

Authors:  Diego Arroyo; Stéphane Cook
Journal:  Minim Invasive Surg       Date:  2011-07-31

5.  Advanced mechanical circulatory support for post-cardiotomy cardiogenic shock: a 20-year outcome analysis in a non-transplant unit.

Authors:  Maziar Khorsandi; Kasra Shaikhrezai; Sai Prasad; Renzo Pessotto; William Walker; Geoffrey Berg; Vipin Zamvar
Journal:  J Cardiothorac Surg       Date:  2016-02-18       Impact factor: 1.637

6.  A 20-year multicentre outcome analysis of salvage mechanical circulatory support for refractory cardiogenic shock after cardiac surgery.

Authors:  Maziar Khorsandi; Scott Dougherty; Andrew Sinclair; Keith Buchan; Fiona MacLennan; Omar Bouamra; Philip Curry; Vipin Zamvar; Geoffrey Berg; Nawwar Al-Attar
Journal:  J Cardiothorac Surg       Date:  2016-11-08       Impact factor: 1.637

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.