Literature DB >> 33002747

Real-time nanoleakage and the flow characteristics of calcium silicate root canal filling materials.

Su-Min Park1, Yeon-Jee Yoo2, In-Bog Lee1, WooCheol Lee3.   

Abstract

This study aimed to investigate the real-time nanoleakage and flow characteristics of calcium silicate-based (Ca-Si) root canal filling materials. Extracted human teeth (n = 30) were decoronated and standardized in their inner and outer dimensions. After root canal enlargement, the roots were filled with gutta-percha (GP) and AH26 sealer, GP and EndoSeal MTA sealer, or Biodentine. The roots were connected to a Nanoflow device (IB Systems) under hydrostatic pressure (40 cm∙H2O) and fluid flow was traced through the filled roots. Data were detected at the nanoscale twice per second and automatically recorded in units of nL/s. Leakage was quantified as the mean slope until the curve plateaued over time, and all static flow intervals lasting longer than 1 s were analyzed to identify any increase in flow and duration. Data were statistically analyzed using the Kruskal-Wallis test. The calculated leakage values were 0.0670 ± 0.0516 nL/s for GP/AH26, 0.1397 ± 0.1579 nL/s for GP/EndoSeal MTA, and 0.0358 ± 0.0538 nL/s for Biodentine, with no statistically significant differences among the root filling materials (P > 0.05). An analysis of real-time flow data for 1000 s to identify spot trends and the overall tendency of flow until a plateau was reached revealed a stepwise increase in the roots filled with Ca-Si material, whereas the GP/AH26-filled roots showed a linear increase. Real-time measurements under hydrostatic pressure with the Nanoflow device enabled precise fluid flow tracing through the root canal filling material. In terms of nanoleakage, the tested root canal filling materials showed no significant differences, while the real-time flow patterns of roots filled with Ca-Si material showed different characteristics from those of GP/AH26-filled roots.
Copyright © 2020 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Calcium silicate material; Nanoflow; Nanoleakage; Real-time

Mesh:

Substances:

Year:  2020        PMID: 33002747     DOI: 10.1016/j.jmbbm.2020.104111

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  2 in total

Review 1.  Present status and future directions: Hydraulic materials for endodontic use.

Authors:  Josette Camilleri; Amre Atmeh; Xin Li; Nastaran Meschi
Journal:  Int Endod J       Date:  2022-03-17       Impact factor: 5.165

2.  Evaluation of a Novel Tool for Apical Plug Formation during Apexification of Immature Teeth.

Authors:  Yasser Alsayed Tolibah; Line Droubi; Saleh Alkurdi; Mohammad Tamer Abbara; Nada Bshara; Thuraya Lazkani; Chaza Kouchaji; Ibrahim Ali Ahmad; Ziad D Baghdadi
Journal:  Int J Environ Res Public Health       Date:  2022-04-27       Impact factor: 4.614

  2 in total