Finite Element Analysis of Insertion Angle of Absorbable Screws for the Fixation of Radial Head Fractures.

Guang-Ming Xu1, Zi-Yang Liang2, Wei Li1, Zheng-Zhong Yang1, Zhi-Bin Chen1, Jie Zhang1.   

Abstract

OBJECTIVE: To investigate the biomechanical effects of different insertion angles of absorbable screws for the fixation of radial head fractures.
METHODS: The finite element models used to simulate the fractures were created based on CT scans. Two absorbable screws were used to fix and maintain the stability of the fracture, and the angles between the screws were set to 0°, 15°, 30°, 45°, 60°, 75°, and 90°. A downward force of 100 N was applied at the stress point, which was coupled with the surface, and the distal radius was limited to six degrees of freedom. The direction and location of the applied force were the same in each model. The values of the von Mises stress and peak displacements were calculated.
RESULTS: Under the applied load and different screw angles, the maximum von Mises stress in the screws was concentrated on the surface contacting the fracture surfaces. The maximum von Mises equivalent stress in the screw decreased when the angle increased from 0° (19.54 MPa) to 45° (13.11 MPa) and increased when the angle further increased to 90° (24.63 MPa). The peak displacement decreased as the angle increased from 0° (0.19 mm) to 45° (0.15 mm) and increased when the angle further increased to 90° (0.25 mm).
CONCLUSION: The computational stress distribution showed that fixation with absorbable screws is safe for patients. Moreover, the minimum von Mises stress and displacements were generated when the angle between the screws was 45°; hence, this setting should be recommended for Mason type II radial fractures.
© 2020 The Authors. Orthopaedic Surgery published by Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

Entities:  

Keywords:  Absorbable implant; Finite element analysis; Radius fracture

Year:  2020        PMID: 33000562      PMCID: PMC7767780          DOI: 10.1111/os.12797

Source DB:  PubMed          Journal:  Orthop Surg        ISSN: 1757-7853            Impact factor:   2.071


  25 in total

1.  Analysis of stress distribution in the humeroradial joint.

Authors:  Kazuhiro Takatori; Hiroyuki Hashizume; Hirofumi Wake; Hajime Inoue; Noriyuki Nagayama
Journal:  J Orthop Sci       Date:  2002       Impact factor: 1.601

2.  A comparative study of two types of sternal pins used for sternal closure: poly-L-lactide sternal pins versus uncalcined hydroxyapatite poly-L-lactide sternal pins.

Authors:  Xian-ming Fu; Hideki Oshima; Yoshimori Araki; Yuji Narita; Masato Mutsuga; Noritaka Okada; Tomohiro Tsunekawa; Akihiko Usui
Journal:  J Artif Organs       Date:  2013-08-31       Impact factor: 1.731

Review 3.  Radial Head Fracture Fixation Using Tripod Technique With Headless Compression Screws.

Authors:  Marc D Lipman; Trenton M Gause; Victor A Teran; A Bobby Chhabra; D Nicole Deal
Journal:  J Hand Surg Am       Date:  2018-04-27       Impact factor: 2.230

Review 4.  Anatomy and biomechanics of the elbow.

Authors:  Chris D Bryce; April D Armstrong
Journal:  Orthop Clin North Am       Date:  2008-04       Impact factor: 2.472

Review 5.  Current concepts review - fractures in the region of the elbow.

Authors:  G Gradl; J B Jupiter
Journal:  Acta Chir Orthop Traumatol Cech       Date:  2012       Impact factor: 0.531

6.  Surgical treatment of calcaneal fractures with bioabsorbable screws.

Authors:  Jingwei Zhang; Baiping Xiao; Zhijun Wu
Journal:  Int Orthop       Date:  2011-01-05       Impact factor: 3.075

7.  A biomechanical study of headless compression screws versus a locking plate in radial head fracture fixation.

Authors:  Paul R Rebgetz; Luca Daniele; Ian D Underhill; Andreas Öchsner; Fraser J Taylor
Journal:  J Shoulder Elbow Surg       Date:  2019-01-24       Impact factor: 3.019

8.  Biomechanical analysis of the annular ligament in Monteggia fractures using finite element models.

Authors:  Jiangwei Tan; Mingzhang Mu; Guangjun Liao; Yong Zhao; Jianmin Li
Journal:  J Orthop Surg Res       Date:  2015-03-04       Impact factor: 2.359

9.  Comparison between absorbable pins and mini-screw fixations for the treatment of radial head fractures Mason type II-III.

Authors:  Luigi Tarallo; Raffaele Mugnai; Martina Rocchi; Francesco Capra; Fabio Catani
Journal:  BMC Musculoskelet Disord       Date:  2018-03-27       Impact factor: 2.362

10.  Comparative Biomechanical Analysis of Stress-Strain State of the Elbow Joint After Displaced Radial Head Fractures.

Authors:  Sergey Strafun; Ievgen Levadnyi; Vasily Makarov; Jan Awrejcewicz
Journal:  J Med Biol Eng       Date:  2017-09-26       Impact factor: 1.553

View more
  1 in total

1.  Effect of the In Situ Screw Implantation Region and Angle on the Stability of Lateral Lumbar Interbody Fusion: A Finite Element Study.

Authors:  Guangye Zhu; Zhihua Wu; Zhichao Fang; Peng Zhang; Jiahui He; Xiang Yu; Zhilin Ge; Kai Tang; Xiaobing Jiang; Ziyang Liang; Jianchao Cui
Journal:  Orthop Surg       Date:  2022-06-03       Impact factor: 2.279

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.