Literature DB >> 33000529

A new concept for improved quantitative analysis of reversible transverse relaxation in tissues with variable microscopic field distribution.

Günter Steidle1, Fritz Schick1.   

Abstract

PURPOSE: The intravoxel distribution of the magnetic field strongly influences signal dephasing after RF excitation and the resulting signal decay in gradient echo-based MRI. In this work, several different field distribution models were applied and tested for analysis of microscopic field characteristics within pixels. THEORY: A flexible model for improved pixel-wise characterization of the underlying field distribution is introduced. The proposed symmetric alpha-stable (SαS) distribution covers Lorentzian, Gaussian, and intermediate field distributions in a continuous way using a two-parametric (width and shape) function.
METHODS: The new model was applied on human brain, potatoes (homogeneous isotropic tissue), and stems of pineapple (anisotropic fibrous tissue). Effects of microscopic structure and background gradients on the shape and the widths of the microscopic field distribution were analyzed using gradient echo sampling of the spin echo and multigradient-echo sequences. Effects of non-Lorentzian shapes of microscopic field distributions on the results of common T 2 ∗ measurements with mono-exponential fitting of signal values were tested.
RESULTS: Many pixels of the examined objects showed field characteristics in between Lorentzian and Gaussian shapes. Microscopic field inhomogeneities caused by microscopic susceptibility effects and background gradients sometimes led to rather Gaussian than Lorentzian field distribution. In cases with nearly Gaussian field distribution, mono-exponential fitting of the signal decay resulted in different T 2 ∗ values, depending on the sampling points.
CONCLUSIONS: Using the concept of more flexible distributions for characterization of microscopic susceptibility effects in tissue provides better fitting of data and nearly sampling point-independent results than common T 2 ∗ measurements with mono-exponential fitting.
© 2020 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  zzm321990 zzm321990 zzm321990 Tzzm321990 2zzm321990 zzm321990 zzm321990 zzm321990-weighted imaging; GESSE; magnetic field distribution; transverse relaxation

Mesh:

Year:  2020        PMID: 33000529     DOI: 10.1002/mrm.28534

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  1 in total

1.  Information theoretic evaluation of Lorentzian, Gaussian, Voigt, and symmetric alpha-stable models of reversible transverse relaxation in cervical cancer in vivo at 3 T.

Authors:  Pelin Ciris
Journal:  MAGMA       Date:  2022-08-04       Impact factor: 2.533