The robustness of VMAT radiotherapy for breast cancer with tissue deformations.

Maija Rossi1, Tuomas Virén2, Janne Heikkilä2, Jan Seppälä3, Eeva Boman4.   

Abstract

To investigate the near-surface doses and target coverage in modulated arc radiotherapy (RT) of the breast or chest wall in two treatment planning systems (TPS) in the presence of soft tissue deformations. This retrospective study consisted of 10 breast cancer patients with axillary lymph node inclusion. For each case, five RT plans were created: (1) tangential 3D conformal field-in-field (FinF) technique; (2) 200° to 240° arcs with optimization bolus (OB) in Eclipse (EB); (3) 243° to 250° arcs with an 8-mm OB in Monaco (MB); (4) 243° to 250° arcs with automatic skin flash tool (ASF) in Monaco TPS (MA); (5) 243° to 250° arcs with both ASF and OB in Monaco (MAB). Soft tissue deformation was simulated by editing CT-images with 4-, 8-, and 12-mm swelling and recalculating the dose. The increasing swelling from 0 to 12 mm caused the coverage (V95%) in clinical target volume to decrease from 96% ± 2% to 90% ± 6% for the FinF plans. For volumetric-modulated arc therapy (VMAT), the coverage decreased from 99% ± 1% to 92% ± 4% in the EB plans, and from 97% ± 1% to 68% ± 8%, 85% ± 6%, and 86% ± 5% for MA, MB, and MAB, respectively. The mean dose in the surface extending from 0 to 3 mm from the skin decreased on average 5%, 17%, 20%, 15%, and 8% in FinF, EB, MA, MB, and MAB, respectively. In the Monaco plans, the use of an OB(+ASF) provided better target coverage and lower dose maxima despite of tissue swelling than the ASF alone. With modulated arc therapy, we recommend the use of an OB instead of or in addition to the ASF. The use of 8 mm OB with VMAT plans is robust to account deformations extending outside up to 8mm. If soft tissue deformation is larger than 8 mm, the need for replanning should be evaluated.
Copyright © 2020 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Breast cancer; Radiotherapy; Tissue deformations; Treatment planning

Year:  2020        PMID: 32994095     DOI: 10.1016/j.meddos.2020.09.005

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  1 in total

1.  Retrospective evaluation of a robust hybrid planning technique established for irradiation of breast cancer patients with included mammary internal lymph nodes.

Authors:  Marina Hennet; Stephan Radonic; Uwe Schneider; Matthias Hartmann
Journal:  Radiat Oncol       Date:  2022-04-15       Impact factor: 4.309

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.