Literature DB >> 3299186

Normal fetal heart axis and position.

C H Comstock.   

Abstract

Cardiac position and axis were evaluated by ultrasound in 183 normal fetuses; both position and axis were found to be constant throughout gestational life. In the four-chamber view of the fetal heart, the normal axis lies at a 45 degree angle (range 22-75 degrees) to the left of an anteroposterior line drawn from the spine to the anterior chest wall. The normal position of the posterior portion of the heart can also be defined. The axis or position of the heart deviated from the established normal range in 15 cases, the outcome of which is discussed. Abnormal axis was associated with 50% mortality; abnormal position with 81% mortality. Deviation from the normal position of the fetal heart should initiate a search for an intrathoracic mass, whereas an abnormal axis is an indication for fetal echocardiography. Axis and position of the fetal heart are easily evaluated during a standard obstetric scan.

Entities:  

Mesh:

Year:  1987        PMID: 3299186

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  7 in total

Review 1.  Indications for fetal echocardiography.

Authors:  M Small; J A Copel
Journal:  Pediatr Cardiol       Date:  2004 May-Jun       Impact factor: 1.655

2.  Atrioventricular and ventriculoarterial discordance (congenitally corrected transposition of the great arteries): echocardiographic features, associations, and outcome in 34 fetuses.

Authors:  G Sharland; R Tingay; A Jones; J Simpson
Journal:  Heart       Date:  2005-03-10       Impact factor: 5.994

Review 3.  2014 First-trimester ultrasound forum from the Korean Society of Ultrasound in Obstetrics and Gynecology.

Authors:  Soo-Young Oh; Joon Seok Hong; Hyun-Joo Seol; Han Sung Hwang; Hyun Soo Park; Kunwoo Kim; Hyun Sun Ko; Dong-Wook Kwak; Moon Young Kim; Mi Hye Park; Min Jeong Oh; Joong Shin Park; Sa Jin Kim
Journal:  Obstet Gynecol Sci       Date:  2015-01-16

4.  A smaller heart-aorta-angle associates with ascending aortic dilatation and increases wall shear stress.

Authors:  S Petteri Kauhanen; Timo Liimatainen; Elina Kariniemi; Miika Korhonen; Johannes Parkkonen; Juska Vienonen; Ritva Vanninen; Marja Hedman
Journal:  Eur Radiol       Date:  2020-04-22       Impact factor: 5.315

5.  Tilting of the Cardiac Axis During Dobutamine Stress Echocardiography: Potential Marker for Ischemia.

Authors:  Preetham Gunta; Angel López-Candales; Paramdeep Baweja; Michael Sweeney
Journal:  Cureus       Date:  2021-06-11

Review 6.  Technique of fetal echocardiography.

Authors:  Mi-Young Lee; Hye-Sung Won
Journal:  Obstet Gynecol Sci       Date:  2013-07-15

Review 7.  Prenatal diagnosis of congenital heart disease: A review of current knowledge.

Authors:  Nathalie Jeanne Bravo-Valenzuela; Alberto Borges Peixoto; Edward Araujo Júnior
Journal:  Indian Heart J       Date:  2017-12-16
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.