Abstract

Surgical skill of the surgeon can be improved by surgical simulation. Especially in ophthalmology, it is impossible to use real human/non-human primate eyes for ophthalmology surgery practice. However, surgical practice is most important for ophthalmologist. The retina laser surgery is one of the ophthalmology surgeries and it requires more surgical practice for surgeons to use the laser beam precisely to coagulate and fuse small areas of tissue. Dealing with the prospect of vision reduction or vision loss presents a peculiar problem and that can be highly stressful and frustrating for both doctors and patients. In this regard, training for indirect ophthalmoscopy and retinal photocoagulation is undergone using model eyes instead of real eyes. Properties and functioning of an existing model eye are huge and they differ from real human eye such as casings are completely rigid and focusing of retinal fundus is not completely covered. Therefore, this research concentrates to develop a model eye that assimilates close to the human eye by focussing on the maximum viewing area that is not done at the moment. Finally, the design and development of re-engineered model eye for retina laser is fabricated by additive manufacturing. Compared to existing plastic model eye, viewing area and viewing angle of the re-engineered model eye is increased by 16.66% and 6.14%, respectively. Due to design modifications and elimination of the insert, it can be reduced by 18.99% and 13.95% of height and weight of the top casing respectively. Developed re-engineered model eye will improve the surgical and diagnostic skill of the surgeon and increase their confidence and proficiency. It also augments the effective use of essential ophthalmic instruments. Additionally, it can reduce the surgical error and meet the existing demand of actual eyes for surgical practices.

Entities:  

Keywords:  Simulation; additive manufacturing; indirect ophthalmoscopy; reti eye; retinal photocoagulation

Year:  2020        PMID: 32988319     DOI: 10.1177/0954411920960548

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  3 in total

1.  Commentary: Intravitreal injection of formalin as a life hack for ophthalmic wet lab training.

Authors:  John D Akkara; Anju Kuriakose
Journal:  Indian J Ophthalmol       Date:  2021-12       Impact factor: 1.848

2.  Redrawing vitreoretinal surgical training program in the COVID-19 era: Experiences of a tertiary care institute in North India.

Authors:  Ramandeep Singh; Atul Arora; Basavaraj Tigari; Simar Rajan Singh; Mohit Dogra; Deeksha Katoch; Reema Bansal; Vishali Gupta
Journal:  Indian J Ophthalmol       Date:  2022-05       Impact factor: 2.969

Review 3.  3D Printing in Eye Care.

Authors:  Ryan D Larochelle; Scott E Mann; Cristos Ifantides
Journal:  Ophthalmol Ther       Date:  2021-07-29
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.