Literature DB >> 32981379

External validation study of hip peri-prosthetic joint infection with cemented custom-made articulating spacer (CUMARS).

Jonathan Quayle1, Ahmed Barakat1, Antonio Klasan2, Aaina Mittal1, Philip Stott1.   

Abstract

INTRODUCTION: Peri-prosthetic joint infection (PJI) is a devastating complication after total hip arthroplasty (THA). The use of custom-made articulating spacers (CUMARS) has been described for use in the first of 2-stage treatment. We report our outcomes of managing PJI using CUMARS.
METHODS: Patients undergoing 1st-stage revision using the Exeter standard stem, all-polyethylene acetabulum and antibiotic-loaded cement were identified. Medical records were assessed for demographics, microbiological and operative treatment, complications, eradication of infection and reoperations. No postoperative restrictions were enforced. 2nd-stage revision was undertaken in the presence of pain or subsidence.
RESULTS: 53 patients underwent 1st-stage revision using this technique. The average follow-up was 3.9 (range 0.5-7.2) years. Infection was eradicated in 47 (88.7%) patients. 2 patients had chronic infection managed with suppressive antibiotics, 2 patients died before eradication confirmed, 1 patient had raised inflammatory markers but no positive aspiration cultures, 1 patient was lost to follow-up. Complications occurred in 5 (9.4%) patients - 4 dislocations and 1 infected haematoma. 4 patients required a repeated 1st stage. 2nd-stage revision was performed in 19 patients (35%).
CONCLUSIONS: The CUMARS technique is an effective way of eradicating PJI after THA. It maintains function by providing a stable construct that permits weight-bearing. It delays or negates the need for 2nd-stage revision. Furthermore, it allows surgeons to choose between managing patients prospectively as a single-stage revision with the option of reverting to a 2nd stage.

Entities:  

Keywords:  CUMARS; Cement; peri-prosthetic joint infection; total hip arthroplasty

Mesh:

Substances:

Year:  2020        PMID: 32981379     DOI: 10.1177/1120700020960669

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  3 in total

1.  Improved patient reported outcomes with functional articulating spacers in two-stage revision of the infected hip.

Authors:  Ewout S Veltman; Dirk Jan F Moojen; Rudolf W Poolman
Journal:  World J Orthop       Date:  2020-12-18

2.  Management of peri-prosthetic joint infection and severe bone loss after total hip arthroplasty using a long-stemmed cemented custom-made articulating spacer (CUMARS).

Authors:  J Quayle; A Barakat; A Klasan; A Mittal; G Chan; J Gibbs; M Edmondson; P Stott
Journal:  BMC Musculoskelet Disord       Date:  2021-04-16       Impact factor: 2.362

Review 3.  Articular spacers in two-stage revision arthroplasty for prosthetic joint infection of the hip and the knee.

Authors:  Andy Craig; S W King; B H van Duren; V T Veysi; S Jain; J Palan
Journal:  EFORT Open Rev       Date:  2022-02-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.