Radiation dose monitoring in computed tomography: Status, options and limitations.

Ioannis A Tsalafoutas1, Mohammad Hassan Kharita1, Huda Al-Naemi1, Mannudeep K Kalra2.   

Abstract

In the last few years there has been an increasing interest on radiation dose to patients undergoing various diagnostic or therapeutic procedures with the use of ionizing radiation. Especially for CT examinations and interventional procedures, where it is known that patient doses are much higher than conventional radiography, new norms have been published that require to have appropriate radiation dose indices registered in the patient medical record. Because of these demands, dose monitoring has been recommended and adopted into many clinical practices as a routine procedure for every patient and every examination. Dedicated dose monitoring systems (DMS) that facilitate data collection and processing, statistical comparisons, reporting and management of radiation dose related information have been devised and are being used worldwide. In this review paper, a brief flashback to the reasons that necessitated dose monitoring in radiology will be first presented. Furthermore, since the focus of this manuscript is on CT, the CT dosimetry principles and metrics will be summarized. The limitations of these metrics will be also discussed, so that DMS users are aware of the semantics of the parameters shown in the DMS reports. The operation of DMS systems will be outlined to make users aware of functions, limitations, and available options of DMS systems. Furthermore, the usefulness of DMS systems as an optimization tool will be presented and discussed. Finally, information about the DMS solutions available in the market and relevant links will be presented.
Copyright © 2020. Published by Elsevier Ltd.

Entities:  

Keywords:  CT; Dose monitoring; Radiation dose; Radiation safety

Mesh:

Year:  2020        PMID: 32980754     DOI: 10.1016/j.ejmp.2020.08.020

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  3 in total

1.  Five-star rating system for acceptable quality and dose in CT.

Authors:  Mannudeep K Kalra; Madan M Rehani
Journal:  Eur Radiol       Date:  2021-06-11       Impact factor: 5.315

Review 2.  Radiation protection perspective to recurrent medical imaging: what is known and what more is needed?

Authors:  Jenia Vassileva; Ola Holmberg
Journal:  Br J Radiol       Date:  2021-06-23       Impact factor: 3.629

3.  An Individualized Contrast-Enhanced Liver Computed Tomography Imaging Protocol Based on Body Mass Index in 126 Patients Seen for Liver Cirrhosis.

Authors:  Jian Jiang; Maowei Zhang; Yuan Ji; Chunfeng Li; Xin Fang; Shuyuan Zhang; Wei Wang; Lijun Wang; Ailian Liu
Journal:  Med Sci Monit       Date:  2021-06-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.