Literature DB >> 32976266

Computed Tomography-Guided Biopsy for Small (≤20 mm) Lung Nodules: A Meta-Analysis.

Guang-Sheng Liu1, Shao-Qing Wang2, Hui-Ling Liu3, Yi Liu3, Yu-Fei Fu4, Yi-Bing Shi4.   

Abstract

PURPOSE: This study was designed to evaluate the diagnostic accuracy of computed tomography (CT)-guided biopsy for small lung nodules (SLNs) (≤20 mm) and to assess related complication rates.
METHODS: We reviewed the Pubmed, Embase, and Cochrane Library databases to identify all relevant studies published as of April 2020. Random effects modeling were then used to evaluate pooled data pertaining to technical success rates, diagnostic accuracy, pneumothorax rates, and rates of hemoptysis. The meta-analysis was conducted using Stata v12.0.
RESULTS: In total, we identified 25 relevant studies for incorporation into this meta-analysis, incorporating 2922 total CT-guided lung biopsy. Pooled technical success rates, diagnostic accuracy, pneumothorax rates, and hemoptysis rates were 94% (95% confidential interval [CI], 0.91-0.98), 90% (95% CI, 0.88-0.93), 19% (95% CI:, 0.15-0.24), and 12% (95% CI, 0.08-0.15), respectively. We observed significant heterogeneity among these studies for all 4 of these parameters (I = 90.0%, 82.7%, 88.6%, and 88.4%, respectively). When we conducted a meta-regression analysis, we did not identify any variables that influenced diagnostic accuracy or technical success, pneumothorax, or hemoptysis rates. Publication bias risk analyses suggested that there was relatively little risk of publication bias pertaining to pneumothorax rates (P = 0.400) or hemoptysis rates (P = 0.377). In contrast, we detected a high risk of publication bias pertaining to reported technical success rates (P = 0.007) and diagnostic accuracy (P = 0.000).
CONCLUSIONS: A CT-guided biopsy can be safely and effectively used to diagnose SLNs.

Entities:  

Mesh:

Year:  2020        PMID: 32976266     DOI: 10.1097/RCT.0000000000001071

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  5 in total

1.  Computed tomography-guided core needle biopsy for sub-centimeter pulmonary nodules.

Authors:  Hui Hui; Hai-Tao Yin; Tao Wang; Gang Chen
Journal:  Kardiochir Torakochirurgia Pol       Date:  2022-06-29

2.  Computed tomography-guided lung biopsy for molecular tests: a meta-analysis.

Authors:  Jian-Hua Zhang; Feng-Fei Xia; Xiao-Shan Yang; Yu Li
Journal:  Kardiochir Torakochirurgia Pol       Date:  2022-06-29

3.  Trans-scapular approach coil localization for scapular-blocked pulmonary nodules: a retrospective study.

Authors:  Juan Wu; Min-Ge Zhang; Jin Chen; Wen-Bin Ji
Journal:  J Cardiothorac Surg       Date:  2021-03-25       Impact factor: 1.637

4.  Clinical-radiological predictive model in differential diagnosis of small (≤ 20 mm) solitary pulmonary nodules.

Authors:  Hai-Cheng Zhao; Qing-Song Xu; Yi-Bing Shi; Xi-Juan Ma
Journal:  BMC Pulm Med       Date:  2021-09-05       Impact factor: 3.317

5.  Application of rapid on‑site evaluation in computed tomography‑guided percutaneous transthoracic needle biopsy of pulmonary nodules of ≤2.0 cm in diameter.

Authors:  Dongxu Wang; Qing Zhang; Yuguang Wang; Wei Dou; Guoxu Ding; Qiuting Wen; Ying Han; Youli Du; Bo Li
Journal:  Exp Ther Med       Date:  2022-09-07       Impact factor: 2.751

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.