Literature DB >> 32975347

Safety and efficacy of high power shorter duration ablation for atrial fibrillation: A systematic review and meta-analysis.

Miao-Fu Li1, Jing Wu2, Chao-Lun Jin1, Chao-Feng Chen2, Yi-Zhou Xu1,2.   

Abstract

BACKGROUND: Radiofrequency ablation in patients with atrial fibrillation (AF) is effective but hampered by pulmonary veins reconnection because of insufficient lesions. High power shorter duration ablation (HPSD) was seen to increase efficacy and safety. This analysis aimed to evaluate the clinical benefits of HPSD in patients with AF.
METHODS: The Medline, PubMed, Embase, and the Cochrane Library databases were searched for studies comparing HPSD and Low power longer duration (LPLD) ablation.
RESULTS: A total of seven trials with 2023 patients were included in the analysis. Pooled analyses demonstrated that HPSD showed a benefit of first-pass pulmonary vein isolation (PVI) [risk ratio (RR): 1.27; 95% confidence interval (CI): 1.18-1.37, P < .001]. HPSD could reduce recurrence of atrial arrhythmias (RR: 0.70; 95% CI: 0.50-0.98, P = .04). Additionally, HPSD was more beneficial in terms of procedural time [Weighted Mean Difference, (WMD): -44.62; 95% CI, -63.00 to -26.23, P < .001], ablation time (WMD: -21.25; 95% CI: -25.36 to -17.13, P < .001), and fluoroscopy time (WMD: -4.13; 95% CI: -7.52 to -0.74, P < .001). Moreover, major complications and esophageal thermal injury (ETI) were similar between two groups (RR: 0.75; 95% CI: 0.44-1.30, P = .31) and (RR: 0.64; 95% CI: 0.17-2.39, P = .51).
CONCLUSION: HPSD was safe and efficient for treating AF with clear advantages of procedural features, it also showed benefits of higher first-pass PVI and reducing recurrence of atrial arrhythmias compared with the LPLD. Moreover, major complications and ETI were similar between two groups.
© 2020 John Wiley & Sons Ltd.

Entities:  

Mesh:

Year:  2020        PMID: 32975347     DOI: 10.1111/ijcp.13732

Source DB:  PubMed          Journal:  Int J Clin Pract        ISSN: 1368-5031            Impact factor:   2.503


  4 in total

1.  High-resolution mapping as an alternative for exit block testing in the presence of entrance block after high-power short-duration pulmonary vein isolation.

Authors:  Sebastian Weyand; Matthias Beuter; David Heinzmann; Peter Seizer
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2022-09-09

Review 2.  Efficiency, Safety, and Efficacy of High-Power Short-Duration Radiofrequency Ablation in Patients with Atrial Fibrillation.

Authors:  Xuerong Sun; Jiang Lu; Jinxuan Lin; Tianjie Feng; Ni Suo; Lihui Zheng; Zhimin Liu; Gang Chen; Xiaohan Fan; Shu Zhang; Guodong Niu
Journal:  Cardiol Res Pract       Date:  2021-02-15       Impact factor: 1.866

3.  The superiority of high-power short-duration radiofrequency catheter ablation strategy for atrial fibrillation treatment: A systematic review and meta-analysis study.

Authors:  Yoga Waranugraha; Ardian Rizal; Achmad J Firdaus; Fransiska A Sihotang; Akita R Akbar; Defyna D Lestari; Muhammad Firdaus; Akhmad I Nurudinulloh
Journal:  J Arrhythm       Date:  2021-07-02

4.  Comparison between High-Power Short-Duration and Conventional Ablation Strategy in Atrial Fibrillation: An Updated Meta-Analysis.

Authors:  Mohan Li; Yingxu Ma; Qiuzhen Lin; Yunying Huang; Yaozhong Liu; Tao Tu; Qiming Liu
Journal:  Cardiovasc Ther       Date:  2022-07-29       Impact factor: 3.368

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.