Literature DB >> 32974984

Fully self-gated free-running 3D Cartesian cardiac CINE with isotropic whole-heart coverage in less than 2 min.

Thomas Küstner1, Aurelien Bustin1, Olivier Jaubert1, Reza Hajhosseiny1, Pier Giorgio Masci1, Radhouene Neji1,2, René Botnar1,3, Claudia Prieto1,3.   

Abstract

PURPOSE: To develop a novel fast water-selective free-breathing 3D Cartesian cardiac CINE scan with full self-navigation and isotropic whole-heart (WH) coverage.
METHODS: A free-breathing 3D Cartesian cardiac CINE scan with a water-selective balanced steady-state free precession and a continuous (non-ECG-gated) variable-density Cartesian sampling with spiral profile ordering, out-inward sampling and acquisition-adaptive alternating tiny golden and golden angle increment between spiral arms is proposed. Data is retrospectively binned based on respiratory and cardiac self-navigation signals. A translational respiratory-motion-corrected and cardiac-motion-resolved image is reconstructed with a multi-bin patch-based low-rank reconstruction (MB-PROST) within about 15 min. A respiratory-motion-resolved approach is also investigated. The proposed 3D Cartesian cardiac CINE is acquired in sagittal orientation in 1 min 50 s for 1.9 mm3 isotropic WH coverage. Left ventricular (LV) function parameters and image quality derived from a blinded reading of the proposed 3D CINE framework are compared against conventional multi-slice 2D CINE imaging in 10 healthy subjects and 10 patients with suspected cardiovascular disease.
RESULTS: The proposed framework provides free-breathing 3D cardiac CINE images with 1.9 mm3 spatial and about 45 ms temporal resolution in a short acquisition time (<2 min). LV function parameters derived from 3D CINE were in good agreement with 2D CINE (10 healthy subjects and 10 patients). Bias and confidence intervals were obtained for end-systolic volume, end-diastolic volume and ejection fraction of 0.1 ± 3.5 mL, -0.6 ± 8.2 mL and -0.1 ± 2.2%, respectively.
CONCLUSION: The proposed framework enables isotropic 3D Cartesian cardiac CINE under free breathing for fast assessment of cardiac anatomy and function.
© 2020 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

Entities:  

Keywords:  3D CINE; Cartesian, free running; bSSFP; cardiovascular imaging; low-rank reconstruction; whole heart

Year:  2020        PMID: 32974984     DOI: 10.1002/nbm.4409

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  3 in total

Review 1.  Cardiac MR: From Theory to Practice.

Authors:  Tevfik F Ismail; Wendy Strugnell; Chiara Coletti; Maša Božić-Iven; Sebastian Weingärtner; Kerstin Hammernik; Teresa Correia; Thomas Küstner
Journal:  Front Cardiovasc Med       Date:  2022-03-03

2.  Volumetric coronary endothelial function assessment: a feasibility study exploiting stack-of-stars 3D cine MRI and image-based respiratory self-gating.

Authors:  Gabriele Bonanno; Robert G Weiss; Davide Piccini; Jérôme Yerly; Sahar Soleimani; Li Pan; Xiaoming Bi; Allison G Hays; Matthias Stuber; Michael Schär
Journal:  NMR Biomed       Date:  2021-07-21       Impact factor: 4.044

3.  Automatic segmentation and volumetric assessment of internal organs and fatty tissue: what are the benefits?

Authors:  Fritz Schick
Journal:  MAGMA       Date:  2021-12-17       Impact factor: 2.310

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.