Automated enzymatic assay for plasma ammonia.

B A Humphries, M Melnychuk, E J Donegan, R D Snee.   

Abstract

An enzymatic method for determining plasma ammonia with the Du Pont Automatic Clinical Analyzer (aca) is described. The assay requires a sample volume of 500 muL for a kinetic ammonia measurement. The reaction is initiated with glutamate dehydrogenase and the rate of depletion of NADPH is monitored with two measurements, 17 s apart, at 340 nm. Reaction conditions have been optimized for maximum sensitivity through both one-factor-at-a-time and multiple variable response surface optimization techniques. Linearity to 1000 mumol of ammonia per liter of plasma has been achieved. No significant interferences were observed from anticoagulants or endogenous blood components, including pyruvate and oxalacetate. Use of the coenzyme NADPH (instead of NADH) in this aca procedure eliminates the lengthy pre-incubation otherwise required for endogenous dehydrogenase reactions.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 32974

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  5 in total

1.  Significant correlations between the flow volume of patent ductus venosus and early neonatal liver function: possible involvement of patent ductus venosus in postnatal liver function.

Authors:  K Murayama; H Nagasaka; K Tate; Y Ohsone; M Kanazawa; K Kobayashi; Y Kohno; M Takayanagi
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2006-01-31       Impact factor: 5.747

2.  Nylon tube-immobilized creatinine iminohydrolase and glutamate dehydrogenase in serum and urine creatinine analysis.

Authors:  J S Colliss; R Ginman
Journal:  Appl Biochem Biotechnol       Date:  1984-06       Impact factor: 2.926

3.  Biochemical diagnosis of liver disease.

Authors:  P L Wolf
Journal:  Indian J Clin Biochem       Date:  1999-01

4.  Physiological Role of Glutamate Dehydrogenase in Cancer Cells.

Authors:  Rafael Moreno-Sánchez; Álvaro Marín-Hernández; Juan C Gallardo-Pérez; Silvia C Pacheco-Velázquez; Diana X Robledo-Cadena; Joaquín Alberto Padilla-Flores; Emma Saavedra; Sara Rodríguez-Enríquez
Journal:  Front Oncol       Date:  2020-04-09       Impact factor: 6.244

5.  A continuous kinetic assay for protein and DNA methyltransferase enzymatic activities.

Authors:  Dan Levy; Amir Aharoni; Shai Duchin; Zlata Vershinin
Journal:  Epigenetics Chromatin       Date:  2015-12-15       Impact factor: 4.954

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.