Literature DB >> 32972916

Factors affecting central corneal thickness measurement agreement between Scheimpflug imaging and ultrasound pachymetry in keratoconus.

Nir Sorkin1,2, Neera Singal3,4, Wendy Hatch4, Anamika Ohri5, Hyejung Jung6, Lacey Haines5, Luigina Sorbara5, Michael Mimouni3.   

Abstract

PURPOSE: To evaluate the agreement of central corneal thickness (CCT) measurement between Scheimpflug imaging and ultrasound (U/S) pachymetry in keratoconic eyes, and investigate factors that affect the agreement.
METHODS: This post hoc analysis within a prospective, observational non-randomised study preformed at the Kensington Eye Institute, Toronto, Ontario, Canada, included crosslinking candidates with progressive keratoconus (KC). Main outcome measures were the agreement of CCT measurement between Scheimpflug imaging (Pentacam Oculus, Wetzlar, Germany) and U/S pachymetry (PachPen 24-5100, Accutome Inc., Malvern, Pennsylvania, USA), and factors that affect the agreement.
RESULTS: A total of 794 keratoconic eyes of 456 subjects with a mean age of 27.6±8.0 years (69.7% males and 49.6% right eyes) were included. Agreement between devices was moderate (intraclass correlation coefficient: 74.9%, Bland-Altman limits of agreement: -48.5 μm to +62.5 μm). In a multivariable analysis, cone decentration (p<0.001, coefficient +10.13 [+6.73 to +13.53 95% CIs]) and Kmax (p<0.001, coefficient +0.68 [+0.46 to +0.90 95% CIs]) were significantly associated (both clinically and statistically) with the level of agreement between the devices; the discrepancy in CCT between the devices increased on average by 10.13 μm for every mm of cone decentration, and by 6.8 μm for every 10D of Kmax. Age, corneal astigmatism and spherical equivalent were statistically but not clinically significant factors affecting agreement.
CONCLUSION: The agreement of CCT measurement between Scheimpflug imaging and U/S pachymetry in KC was moderate. To ensure the safety of crosslinking in keratoconic corneas, Scheimpflug and U/S CCT measurements should not be used interchangeably, especially in steep corneas and corneas with decentred cones. © Author(s) (or their employer(s)) 2021. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  Cornea; Diagnostic tests/Investigation; Imaging

Mesh:

Year:  2020        PMID: 32972916     DOI: 10.1136/bjophthalmol-2020-317111

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  1 in total

1.  The diagnostic value of 123I-IMP SPECT in ocular adnexal lymphoma.

Authors:  Naoyuki Harada; Kosuke Kondo; Sayaka Terazono; Kei Uchino; Yutaka Fuchinoue; Nobuo Sugo
Journal:  Int Ophthalmol       Date:  2021-11-02       Impact factor: 2.031

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.