Literature DB >> 32970882

Frequency-stabilized chemical exchange saturation transfer imaging with real-time free-induction-decay readout.

Ruibin Liu1, Hongxi Zhang2, Yue Qian3, Yi-Cheng Hsu4, Caixia Fu5, Yi Sun4, Dan Wu1, Yi Zhang1.   

Abstract

PURPOSE: To correct the temporal B0 drift in chemical exchange saturation transfer (CEST) imaging in real-time with extra free-induction-decay (FID) readout. THEORY AND METHODS: The frequency stabilization module of the recently proposed frequency-stabilized CEST (FS-CEST) sequence was further simplified by replacing the original three k-space lines of gradient-echo (GRE) readout with a single k-space line of FID readout. The B0 drift was quantified using the phase difference between the odd and even parts of the FID signal in the frequency stabilization module and then used to update the B0 frequency in the succeeding modules. The proposed FS-CEST sequence with FID readout (FID FS-CEST) was validated in phantoms and 16 human subjects on cross-vendor scanners.
RESULTS: In the Siemens experiments, the FID FS-CEST sequence successfully corrected the user-induced B0 drift, generating consistent amide proton transfer-weighted (APTw) images and magnetization transfer ratio asymmetry (MTRasym ) spectra with those from the non-frequency-stabilized CEST (NFS-CEST) sequence without B0 drift. In the Philips experiments, the FID FS-CEST sequence produced more stable APTw images and MTRasym spectra than the NFS-CEST sequence in the presence of practical B0 drift. Quantitatively, the SD of the APTw signal values in the deep gray matter from 15 subjects was 0.26% for the FID FS-CEST sequence compared to 1.03% for the NFS-CEST sequences, with the fluctuations reduced by nearly three-quarters.
CONCLUSIONS: The proposed FS-CEST sequence with FID readout can effectively correct the temporal B0 drift on cross-vendor scanners.
© 2020 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  chemical exchange saturation transfer (CEST); free-induction-decay (FID) readout; frequency stabilization; temporal B0 drift

Mesh:

Substances:

Year:  2020        PMID: 32970882     DOI: 10.1002/mrm.28513

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  1 in total

Review 1.  Review and consensus recommendations on clinical APT-weighted imaging approaches at 3T: Application to brain tumors.

Authors:  Jinyuan Zhou; Moritz Zaiss; Linda Knutsson; Phillip Zhe Sun; Sung Soo Ahn; Silvio Aime; Peter Bachert; Jaishri O Blakeley; Kejia Cai; Michael A Chappell; Min Chen; Daniel F Gochberg; Steffen Goerke; Hye-Young Heo; Shanshan Jiang; Tao Jin; Seong-Gi Kim; John Laterra; Daniel Paech; Mark D Pagel; Ji Eun Park; Ravinder Reddy; Akihiko Sakata; Sabine Sartoretti-Schefer; A Dean Sherry; Seth A Smith; Greg J Stanisz; Pia C Sundgren; Osamu Togao; Moriel Vandsburger; Zhibo Wen; Yin Wu; Yi Zhang; Wenzhen Zhu; Zhongliang Zu; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2022-04-22       Impact factor: 3.737

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.