| Literature DB >> 32968184 |
Gabriella Meloni1,2, Omar Tricinci3, Andrea Degl'Innocenti3, Barbara Mazzolai4.
Abstract
In medical robotics, micromanipulation becomes particularly challenging in the presence of blood and secretions. Nature offers many examples of adhesion strategies, which can be divided into two macro-categories: morphological adjustments and chemical adaptations. This paper analyzes how two successful specializations from different marine animals can converge into a single biomedical device usable in moist environments. Taking inspiration from the morphology of the octopus sucker and the chemistry of mussel secretions, we developed a protein-coated octopus-inspired micro-sucker device that retains in moist conditions about half of the adhesion it shows in dry environments. From a robotic perspective, this study emphasizes the advantages of taking inspiration from specialized natural solutions to optimize standard robotic designs.Entities:
Mesh:
Substances:
Year: 2020 PMID: 32968184 PMCID: PMC7511962 DOI: 10.1038/s41598-020-72493-7
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1General framework. Octopus arms with suckers; a magnified box depicts a sucker section. The “Mold design” box shows the mold array model, with a three-dimensional model of a single mold/sucker (magnified box) and the simplified profile of a single cavity (on the left). SEM images portray a mold array in orthogonal (top lane) or oblique (bottom lane) view. The “Array preparation” box shows the final array model, with a three-dimensional model of a single sucker-like structure (magnified box) and the simplified profile of a single cavity (on the left). SEM images retract a PDMS array in orthogonal (top lane) or oblique (bottom lane) view. The green box shows the outline of the coating method with the adhesive protein mfp-1.
Figure 2Adhesion tests in different conditions. The top-left box contains a simplistic force vs. time diagram, in which the detachment moment corresponds to the adhesion force; all tested conditions are listed, each one represented with different colors. Each condition was tested using three different samples (n = 3), and every sample was tested for ten repetitions. For line charts, dashed curves are used for control experimental classes with flat surfaces. Solid curves mark experimental classes with octopus-inspired micro-suckers. Data dispersions, visualized as ribbons, report standard error of the mean. Bar charts feature averages of the four data points at the right-end (i.e. at plateau) of every curve. The number of asterisks specifies the significance level for different p-value thresholds (ns—i.e. non-significant—for p > 0.05, *for p < 0.05, **for p < 0.01, ***for p < 0.001); solid lines indicate unpaired two-tailed t-test, and dashed lines paired two-tailed t-test. Line ends indicate the two bars compared in each test. Gray asterisks are used for t-tests, and black asterisks for two-tailed Mann–Whitney U-tests; error bars report standard error of the mean. The bottom box represents the underwater application. Images are screenshots from the demonstrative Supplementary Video S1.