Literature DB >> 32956499

Evaluation of Hemodynamics in a Murine Hindlimb Ischemia Model Using Spatial Frequency Domain Imaging.

Katherine A Leyba1, Sandhya Vasudevan2, Thomas D O'Sullivan2, Craig J Goergen1.   

Abstract

BACKGROUND AND OBJECTIVES: Spatial frequency domain imaging (SFDI), an optical imaging technique capable of quantitatively measuring tissue hemodynamics over a large field-of-view, has captured the interest of scientists and clinicians due to its ability to image rapidly and noninvasively. The goal of this study was to apply SFDI in a preclinical murine model to assess its ability to measure hemodynamic changes due to hindlimb ischemia in vivo longitudinally. STUDY DESIGN/
MATERIALS AND METHODS: Complete unilateral femoral artery ligation was performed on a total of nine C57BL/6J mice to induce ischemia in the left hindlimb. Changes in vascular perfusion in each mouse were monitored through SFDI acquisition of both the ischemic and control limbs throughout the course of 4 weeks. High-frequency pulsed-wave Doppler ultrasound was also acquired to confirm occlusion of the left femoral artery post-ligation compared with the control limb, while histological analysis was used to quantify femoral artery lumen shape and size.
RESULTS: Tissue oxygen saturation in the ischemic limb normalized to the control limb decreased from a ratio of 0.96 ± 0.06 at baseline to 0.86 ± 0.10 at day 1, then 0.94 ± 0.06 at day 3, followed by 0.95 ± 0.14 at day 7, 0.91 ± 0.09 at day 14, 0.90 ± 0.09 at day 21, and 1.01 ± 0.09 at day 28.
CONCLUSION: The results of this study indicate the utility of SFDI to detect hemodynamic changes in a preclinical murine model, as well as how to effectively use this tool to extract information regarding ischemia-induced hindlimb changes. In our model, we observed a decline in tissue oxygen saturation within one day post-ischemic injury, followed by a return to baseline values over the 4-week study period. While reducing skin artifacts and modifying camera hardware could still improve this murine imaging approach, our multimodality study presented here suggests that SFDI can be used to reliably characterize ischemia-mediated changes in a clinically relevant mouse model of peripheral arterial disease. Lasers Surg. Med.
© 2020 Wiley Periodicals LLC. © 2020 Wiley Periodicals LLC.

Entities:  

Keywords:  hemodynamics; near-infrared spectroscopy; optical imaging; peripheral artery disease; spatial frequency domain imaging

Mesh:

Year:  2020        PMID: 32956499      PMCID: PMC7981275          DOI: 10.1002/lsm.23320

Source DB:  PubMed          Journal:  Lasers Surg Med        ISSN: 0196-8092


  35 in total

Review 1.  Laser Doppler imaging: a developing technique for application in the rheumatic diseases.

Authors:  A K Murray; A L Herrick; T A King
Journal:  Rheumatology (Oxford)       Date:  2004-06-29       Impact factor: 7.580

2.  Modulated imaging: quantitative analysis and tomography of turbid media in the spatial-frequency domain.

Authors:  David J Cuccia; Frederic Bevilacqua; Anthony J Durkin; Bruce J Tromberg
Journal:  Opt Lett       Date:  2005-06-01       Impact factor: 3.776

Review 3.  Review of methodological developments in laser Doppler flowmetry.

Authors:  Vinayakrishnan Rajan; Babu Varghese; Ton G van Leeuwen; Wiendelt Steenbergen
Journal:  Lasers Med Sci       Date:  2008-01-31       Impact factor: 3.161

4.  Influence of tissue optical properties on laser Doppler perfusion imaging, accounting for photon penetration depth and the laser speckle phenomenon.

Authors:  Vinayakrishnan Rajan; Babu Varghese; Ton G Van Leeuwen; Wiendelt Steenbergen
Journal:  J Biomed Opt       Date:  2008 Mar-Apr       Impact factor: 3.170

5.  Single snapshot imaging of optical properties.

Authors:  Jean Vervandier; Sylvain Gioux
Journal:  Biomed Opt Express       Date:  2013-11-22       Impact factor: 3.732

6.  Fiji: an open-source platform for biological-image analysis.

Authors:  Johannes Schindelin; Ignacio Arganda-Carreras; Erwin Frise; Verena Kaynig; Mark Longair; Tobias Pietzsch; Stephan Preibisch; Curtis Rueden; Stephan Saalfeld; Benjamin Schmid; Jean-Yves Tinevez; Daniel James White; Volker Hartenstein; Kevin Eliceiri; Pavel Tomancak; Albert Cardona
Journal:  Nat Methods       Date:  2012-06-28       Impact factor: 28.547

7.  Performance assessment of diffuse optical spectroscopic imaging instruments in a 2-year multicenter breast cancer trial

Authors:  Thomas D. O'Sullivan; Albert Cerussi; Amanda Durkin; Brian Hill; Nola Hylton; Arjun G. Yodh; Stefan A. Carp; David Boas; Shudong Jiang; Keith D. Paulsen; Brian Pogue; Darren Roblyer; Wei Yang; Bruce J. Tromberg
Journal:  J Biomed Opt       Date:  2017-08-17       Impact factor: 3.170

8.  Angle correction for small animal tumor imaging with spatial frequency domain imaging (SFDI).

Authors:  Yanyu Zhao; Syeda Tabassum; Shaheer Piracha; Mohan Sobhana Nandhu; Mariano Viapiano; Darren Roblyer
Journal:  Biomed Opt Express       Date:  2016-05-24       Impact factor: 3.732

9.  Near-instant noninvasive optical imaging of tissue perfusion for vascular assessment.

Authors:  Craig Weinkauf; Amaan Mazhar; Kairavi Vaishnav; Auon A Hamadani; David J Cuccia; David G Armstrong
Journal:  J Vasc Surg       Date:  2018-10-03       Impact factor: 4.268

10.  Optical sampling depth in the spatial frequency domain.

Authors:  Carole K Hayakawa; Kavon Karrobi; Vivian Pera; Darren Roblyer; Vasan Venugopalan
Journal:  J Biomed Opt       Date:  2019-07       Impact factor: 3.170

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.