Feasibility study of a smartphone pupillometer and evaluation of its accuracy.

Andrew E Neice1, Cedar Fowler2, Richard A Jaffe2, John G Brock-Utne2.   

Abstract

Measurement of pupillary characteristics, such as pupillary unrest in ambient light, and reflex dilation have been shown to be useful in a variety of clinical situations. Dedicated pupillometers typically capture images in the near-infrared to allow imaging in both light and darkness. However, because a subset of pupillary measurements can be acquired with levels of visible light suitable for conventional cameras, it is theoretically possible to capture data using general purpose cameras and computing devices such as those found on smartphones. Here we describe the development of a smartphone-based pupillometer and compare its performance with a commercial pupillometer. Smartphone pupillometry software was developed and then compared with a commercial pupillometer by performing simultaneous scans in both eyes, using the smartphone pupillometer and a commercial pupillometer. The raw scans were compared, as well as a selected pupillary index: pupillary unrest in ambient light. In 77% of the scans the software was able to successfully identify the pupil and iris. The raw data as well as calculated values of pupillary unrest in ambient light were in clinically acceptable levels of agreement; Bland-Altman analysis of raw pupil measurements yielded a 95% confidence interval of 0.26 mm. In certain situations a smartphone pupillometer may be an appropriate alternative to a commercial pupillometer.
© 2020. Springer Nature B.V.

Entities:  

Keywords:  Hippus; PUAL; Pupillary unrest in ambient light; Pupillometer; Smartphone pupillometer

Mesh:

Year:  2020        PMID: 32951188     DOI: 10.1007/s10877-020-00592-x

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   1.977


  1 in total

1.  Evaluation of an iris color classification system. The Eye Disorders Case-Control Study Group.

Authors:  J M Seddon; C R Sahagian; R J Glynn; R D Sperduto; E S Gragoudas
Journal:  Invest Ophthalmol Vis Sci       Date:  1990-08       Impact factor: 4.799

  1 in total
  1 in total

1.  Pilot Study of Smartphone Infrared Pupillography and Pupillometry.

Authors:  Omar Solyman; Mokhtar Mohamed Ibrahim Abushanab; Andrew R Carey; Amanda D Henderson
Journal:  Clin Ophthalmol       Date:  2022-02-08
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.