| Literature DB >> 32948172 |
Long Wang1, Lin Xie1, Weiqiang Ruan1, Tao Li1, Changping Gan1, Ke Lin2.
Abstract
BACKGROUND: This report presents updated data and mid-term follow-up information to a former study introducing the novel technique of percutaneous-perventricular device closure of doubly committed subarterial ventricular septal defect.Entities:
Keywords: Minimally invasive surgery; Ventricular septal defect
Year: 2020 PMID: 32948172 PMCID: PMC7501642 DOI: 10.1186/s12893-020-00854-0
Source DB: PubMed Journal: BMC Surg ISSN: 1471-2482 Impact factor: 2.102
Characteristics of study patients
| Sex (male/female) | 26/28 |
|---|---|
| Mean age at time of procedure (years) | 5.0 ± 6.6 (range, 0.6–14.0) |
| Mean body weight (kg) | 18.7 ± 12.8 (range, 7.8–40.0) |
| Mean VSD diameter by TTE (mm) | 4.4 ± 1.4 (range, 2.0–5.5) |
| Mean VSD diameter by TEE (mm) | 4.4 ± 1.1 (range, 3.0–7.0) |
| Mean eccentric occluder diameter (mm) | 7.1 ± 1.3 (range, 5.0–10.0) |
| Preoperative arrhythmia | |
| Atrioventricular block | 0 (0%) |
| Right bundle branch block | 0 (0%) |
| Other arrhythmia | 0 (0%) |
| Preoperative valve regurgitation | |
| Aortic regurgitation | 10 trivial (18.5%) |
| Pulmonary regurgitation | 1 (1.9%) |
| Tricuspid regurgitation | 5 trivial (9.3%) |
Follow-up outcomes of percutaneous perventricular device closure
| In-Hospital / Follow-Up | Death | Residual Shun | RVOT | Valve Regurgitation | ||
|---|---|---|---|---|---|---|
| n/n(%) | n/n(%) | n/n(%) | AR | PR | TR | |
| After procedure in the OR | 0/54 (0%) | 4/54 (7.4%) | 0/54 (0%) | 1/54 (1.9%) | 0/54 (0%) | 3/54 (0%) |
| Discharge | 0/54 (0%) | 0/54 (0%) | 0/54 (0%) | 0/54 (0%) | 0/54 (0%) | 0/54 (0%) |
| 3 months | 0/54 (0%) | 0/54 (0%) | 0/54 (0%) | 1/54 (1.9%) | 0/54 (0%) | 1/54 (0%) |
| 6 months | 0/49 (0%) | 0/49 (0%) | 0/49 (0%) | 1/49 (2.0%) | 0/49 (0%) | 1/49 (0%) |
| 1 years | 0/41 (0%) | 0/41 (0%) | 0/41 (0%) | 1/41 (2.4%) | 0/41 (0%) | 1/41 (0%) |
| 2 years | 0/32 (0%) | 0/32 (0%) | 0/32 (0%) | 1/32 (3.1%) | 0/32 (0%) | 0/32 (0%) |
| 3 years | 0/24 (0%) | 0/24 (0%) | 0/24 (0%) | 0/24 (0%) | 0/24 (0%) | 0/24 (0%) |
| 4 years | 0/13 (0%) | 0/13 (0%) | 0/13 (0%) | 0/13 (0%) | 0/13 (0%) | 0/13 (0%) |
AR Aortic regurgitation, OR Operating room, PR Pulmonary regurgitation, RVOT Right ventricular outflow tract, TR Tricuspid regurgitation
Fig. 1Red arrow indicates the concentric device was deployed in the right ventricular outflow tract