Literature DB >> 32944709

The Influence of Polymer Processing Methods on Polymer Film Physical Properties and Vascular Cell Responsiveness.

Kaitlyn R Ammann1, Maxwell Li1, Syed Hossainy2, Marvin J Slepian1,3,4.   

Abstract

Implantable vascular devices typically interface with blood and vascular tissues. Physical properties of device materials and coatings, independent of chemical composition, can significantly influence cell responses and implant success. Here, we analyzed the effect of various polymer processing regimes, using a single implant polymer - poly(ε-caprolactone) (PCL), on vascular endothelial cell (EC), smooth muscle cell (SMC), and platelet response. PCL films were formed by varying three parameters: 1) formation method - solvent casting, melt pressing or spin coating; 2) molecular weight - 50 or 100 kDa; and 3) solvent type - dichloromethane (DCM) or tetrahydrofuran (THF). We quantified the relationship of polymer processing choice to surface roughness, wettability, and bulk stiffness; and to EC adhesion, SMC adhesion, and platelet activity state (PAS). Multiple regression analysis identified which processing method signficantly impacted (F-ratio>p-value; p<0.1) polymer physical properties and vascular cell interaction. Film formation method affected PCL roughness (Rq), wettability (°), and stiffness (MPa) with spin coating resulting in the most wettable (81.8±0.7°), and stiffest (1.12±0.07 MPa; p<0.001) polymer film; however, solvent cast films were the roughest (281±66nm). Molecular weight influenced wettability, with the highest wettability on 50 kDa films (79.7±0.7°; p<0.001) and DCM solvent films (83.0±1.0°; p<0.01). The multiple regression model confidently predicted (F-ratio=9.88; p=0.005) wettability from molecular weight (p=0.002) and film formation method (p=0.03); stiffness (F-ratio=4.21; p=0.05) also fit well tofilm formation method (p=0.02). Film formation method impacted SMC adhesion and platelet activity state, but not EC adhesion, with melt press PCL promoting the highest SMC adhesion (18000±1536 SMCs; p<0.05) and PAS (5.0±0.7 %PAS). The regression model confidently fit SMC adhesion (F-ratio=3.15; p=0.09) and PAS (F-ratio=5.30; p=0.05) to polymer processing choices, specifically film formation method (p<0.03). However, only SMC adhesion had a model that fit well (F-ratio=4.13; p=0.05) to the physical properties directly, specifically roughness and wettability (p<0.04).

Entities:  

Keywords:  biomaterials; endothelial cell; platelet; polymer; smooth muscle cell; tissue interaction; vascular

Year:  2019        PMID: 32944709      PMCID: PMC7494131          DOI: 10.1021/acsabm.9b00175

Source DB:  PubMed          Journal:  ACS Appl Bio Mater        ISSN: 2576-6422


  39 in total

Review 1.  Endothelial cell-matrix interactions.

Authors:  Erika Iivanainen; Veli-Matti Kähäri; Jyrki Heino; Klaus Elenius
Journal:  Microsc Res Tech       Date:  2003-01-01       Impact factor: 2.769

2.  Extracellular matrix rigidity governs smooth muscle cell motility in a biphasic fashion.

Authors:  Shelly R Peyton; Andrew J Putnam
Journal:  J Cell Physiol       Date:  2005-07       Impact factor: 6.384

3.  Sensitivity of surface roughness parameters to changes in the density of scanning points in multi-scale AFM studies. Application to a biomaterial surface.

Authors:  A Méndez-Vilas; J M Bruque; M L González-Martín
Journal:  Ultramicroscopy       Date:  2006-12-19       Impact factor: 2.689

4.  Beta3-integrins rather than beta1-integrins dominate integrin-matrix interactions involved in postinjury smooth muscle cell migration.

Authors:  M J Slepian; S P Massia; B Dehdashti; A Fritz; L Whitesell
Journal:  Circulation       Date:  1998-05-12       Impact factor: 29.690

Review 5.  Human Endothelial Cell Models in Biomaterial Research.

Authors:  Sandra Hauser; Friedrich Jung; Jens Pietzsch
Journal:  Trends Biotechnol       Date:  2016-10-24       Impact factor: 19.536

6.  Surface-wetting characterization using contact-angle measurements.

Authors:  Tommi Huhtamäki; Xuelin Tian; Juuso T Korhonen; Robin H A Ras
Journal:  Nat Protoc       Date:  2018-07       Impact factor: 13.491

Review 7.  A critical review of the application of polymer of low concern and regulatory criteria to fluoropolymers.

Authors:  Barbara J Henry; Joseph P Carlin; Jon A Hammerschmidt; Robert C Buck; L William Buxton; Heidelore Fiedler; Jennifer Seed; Oscar Hernandez
Journal:  Integr Environ Assess Manag       Date:  2018-03-30       Impact factor: 2.992

Review 8.  Endothelial cell senescence in aging-related vascular dysfunction.

Authors:  Guanghong Jia; Annayya R Aroor; Cassie Jia; James R Sowers
Journal:  Biochim Biophys Acta Mol Basis Dis       Date:  2018-08-18       Impact factor: 5.187

Review 9.  Biological responses to immobilized microscale and nanoscale surface topographies.

Authors:  Shelby A Skoog; Girish Kumar; Roger J Narayan; Peter L Goering
Journal:  Pharmacol Ther       Date:  2017-07-16       Impact factor: 12.310

10.  Apoptotic vascular endothelial cells become procoagulant.

Authors:  T Bombeli; A Karsan; J F Tait; J M Harlan
Journal:  Blood       Date:  1997-04-01       Impact factor: 22.113

View more