| Literature DB >> 32944263 |
Koichiro Adachi1,2, Jumpei Tuchiya2, Satoru Beppu2, Kei Nishiyama2, Makiko Shimizu1, Hiroshi Yamazaki1.
Abstract
BACKGROUND: The anticoagulant edoxaban is used clinically at doses of 30-60 mg/day; however, we experienced a patient who had taken an overdose of edoxaban of 750 mg. We investigated the pharmacokinetics of edoxaban in this patient by using liquid chromatography-tandem spectrometry to estimate the follow-up period in emergency clinical practice with this medicine. CASEEntities:
Keywords: Anticoagulants; Overdose; Pharmacokinetic modeling
Year: 2020 PMID: 32944263 PMCID: PMC7488402 DOI: 10.1186/s40780-020-00176-6
Source DB: PubMed Journal: J Pharm Health Care Sci ISSN: 2055-0294
Clinical laboratory results in a patient who had taken a single oral overdose of 750 mg of edoxaban
| Time after administration (h) of oral dose | ||||||
|---|---|---|---|---|---|---|
| 8 | 13 | 28 | 36 | 52 | 60 | |
| Activated partial thromboplastin time (s) | 59.4 | 43.0 | 30.9 | 26.2 | 26.1 | 25.9 |
| Prothrombin time (s) | 54.8 | 33.7 | 14.9 | 13.4 | 11.5 | 11.5 |
| International normalized ratio | 4.34 | 2.69 | 1.21 | 1.09 | 0.94 | 0.94 |
| Hemoglobin (g/dL) | 12.8 | 12.1 | 11.9 | 12.1 | ||
| Hematocrit (%) | 36.2 | 35.2 | 36.4 | 33.4 | ||
| Platelet count (per μL) | 197,000 | 168,000 | 187,000 | 170,000 | ||
| Serum creatinine (mg/dL) | 0.76 | 0.82 | 0.93 | 0.82 | 0.83 | 0.73 |
| Creatinine clearance (mL/min) | 89 | 82 | 73 | 82 | 81 | 93 |
Concomitant drugs for this subject were fluvoxamine, lorazepam, valproic acid, promethazine, quazepam, levomepromazine, sertraline, quetiapine, esomeprazole, and polycarbophil calcium, which might not substantially affect the edoxaban pharmacokinetics
Fig. 1Measured (circles) and estimated (lines) plasma concentrations of edoxaban in a patient who took an excessive single oral dose of 750 mg. The plasma concentration curve after virtual administration of 750 mg of edoxaban (solid line) is shown with the 95% confidence interval (broken lines) based on the hepatic intrinsic clearance values of 100 virtual subjects created using random numbers, as described previously [10]. The open circle at 100 h indicates that edoxaban was detectable, but below the measurable limit, using the present liquid chromatography–tandem mass spectrometry system