Literature DB >> 32940070

A comparison of the efficacy, safety, and duration of frame-based and Remebot robot-assisted frameless stereotactic biopsy.

Shiqiang Wu1, Junwen Wang1, Pan Gao1, Weihua Liu1, Feng Hu1, Wei Jiang1, Ting Lei1, Kai Shu1.   

Abstract

OBJECTIVE: The aim of this study was to compare the efficacy, safety, and duration of Remebot robot-assisted frameless brain biopsy with those of standard frame-based stereotactic biopsy. PATIENTS AND METHODS: A retrospective analysis of 66 patients undergoing stereotactic brain biopsy in our department from January 2015 to January 2019 was performed. We divided the patients into two groups: the frame-based group (n = 35) and the Remebot robot group (n = 31). Data on clinical characteristics, total procedure length, overall discomfort, diagnostic yield, complications, and postoperative length of hospital stay were retrospectively reviewed and compared between these two groups.
RESULTS: No significant difference in diagnostic yield was detected in the two groups, with frame-based biopsy having a diagnostic yield of 91.4% and Remebot robot-assisted frameless brain biopsy having a diagnostic yield of 93.5%. The duration of the total procedure was 116.5 min for the frame-based biopsy and 80.1 min for the Remebot robot-assisted frameless brain biopsy (p < 0.001). There were no statistically significant differences in complication rate or postoperative duration of hospitalization between the two groups. The overall patient discomfort in the frame-based group was significantly greater than that in the Remebot robot group (visual analog scale score 2.7 ± 1.2 versus 1.5 ± 0.7, p = 0.001).
CONCLUSIONS: Remebot robot-assisted frameless brain biopsy was as efficacious and safe as standard stereotactic frame-based biopsy. However, frameless biopsy can alleviate the suffering of the patient and reduce the total duration of the procedure. Remebot robot-assisted frameless brain biopsy is easy to use and better accepted by patients than frame-based biopsy.

Entities:  

Keywords:  Brain biopsy; Remebot robot; frame-based stereotaxy; frameless stereotaxy

Mesh:

Year:  2020        PMID: 32940070     DOI: 10.1080/02688697.2020.1812519

Source DB:  PubMed          Journal:  Br J Neurosurg        ISSN: 0268-8697            Impact factor:   1.596


  3 in total

1.  Effect of Robot-Assisted Neuroendoscopic Hematoma Evacuation Combined Intracranial Pressure Monitoring for the Treatment of Hypertensive Intracerebral Hemorrhage.

Authors:  Shiqiang Wu; Heping Wang; Junwen Wang; Feng Hu; Wei Jiang; Ting Lei; Kai Shu
Journal:  Front Neurol       Date:  2021-12-02       Impact factor: 4.003

2.  Stereotactic biopsy for adult brainstem lesions: A surgical approach and its diagnostic value according to the 2016 World Health Organization Classification.

Authors:  In-Ho Jung; Kyung Won Chang; So Hee Park; Ju Hyung Moon; Eui Hyun Kim; Hyun Ho Jung; Seok-Gu Kang; Jong Hee Chang; Jin Woo Chang; Won Seok Chang
Journal:  Cancer Med       Date:  2021-09-12       Impact factor: 4.452

3.  A Comparation Between Frame-Based and Robot-Assisted in Stereotactic Biopsy.

Authors:  Yue Hu; Pu Cai; Huawei Zhang; Aihemaitiniyazi Adilijiang; Jun Peng; Yun Li; Shanli Che; Fei Lan; Changqing Liu
Journal:  Front Neurol       Date:  2022-07-18       Impact factor: 4.086

  3 in total