Literature DB >> 32936405

Influence of double rods and interbody cages on quasistatic range of motion of the spine after lumbopelvic instrumentation.

Yves Ntilikina1,2, Yann Philippe Charles3, Sylvain Persohn4, Wafa Skalli4.   

Abstract

PURPOSE: This in vitro biomechanical study compares residual lumbar range of motion (ROM) and rod strain after lumbopelvic instrumentation using 2 rods, 4 rods and interbody cages.
METHODS: Seven human cadaveric specimens were instrumented from L1 to sacrum, and pelvic screws were implanted. The pelvis was constrained and moments up to 7.5 Nm were applied to T12. Segmental L1-S1 ROM was analyzed by tracking radiopaque balls implanted in each vertebra using biplanar radiographs. Deformation within principal rods was measured by strain gauges. Four configurations were compared: 2 rods (2R), 4 rods (4R), 4 rods + ALIF at L4-L5 and L5-S1 (4R + ALIF), 2 rods + ALIF (2R + ALIF).
RESULTS: Intact average global L1-S1 ROM was 42.9° (27.9°-66.0°) in flexion-extension (FE), 35.2° (26.8°-51.8°) in lateral bending (LB), 18.6° (6.7°-47.8°) in axial rotation (AR). In FE, average ROM was 1.9° with both 4-rod configurations versus 2.5° with 2R and 2.8° with 2R + ALIF (p < 0.05). In LB, ROM ranged between 1.2° and 1.5° without significant differences. In AR, ROM was 2.5° with both 4-rod configurations versus 2.9° with 2R (p = 0.07) and 3.1° with 2R ALIF (p = 0.01). In FE, strain decreased by 64% and 65% in principal rods at L3-L4 with 4-rod. When comparing 2-rod configurations, strain decreased by 1% in flexion and increased by 22% in extension at L3-L4 when adding an ALIF at L4-L5 and L5-S1.
CONCLUSIONS: Double rods and interbody cages decrease residual ROM in FE and AT. Double rods seem efficient in limiting strain in principal rods. The use of single rods with cages at the lumbosacral junction increases strain at the first adjacent level without cage.

Entities:  

Keywords:  Anterior lumbar interbody fusion; Biomechanics; Double rod instrumentation; Lumbosacral range of motion; Pelvic fixation; Rod strain; Spinal deformity

Mesh:

Year:  2020        PMID: 32936405     DOI: 10.1007/s00586-020-06594-2

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  2 in total

1.  Comparison of degenerative lumbar scoliosis correction and risk for mechanical failure using posterior 2-rod instrumentation versus 4-rod instrumentation and interbody fusion.

Authors:  Vincent Lamas; Yann Philippe Charles; Nicolas Tuzin; Jean-Paul Steib
Journal:  Eur Spine J       Date:  2021-05-16       Impact factor: 3.134

Review 2.  Influence of double rods and interbody cages on range of motion and rod stress after spinopelvic instrumentation: a finite element study.

Authors:  Aleksander Leszczynski; Frank Meyer; Yann-Philippe Charles; Caroline Deck; Nicolas Bourdet; Rémy Willinger
Journal:  Eur Spine J       Date:  2022-04-23       Impact factor: 2.721

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.