Literature DB >> 32935894

Three-Dimensional Accuracy of Conventional Versus Digital Complete Arch Implant Impressions.

Berkman Albayrak1, Cortino Sukotjo2, Alvin G Wee3, İsmail Hakkı Korkmaz4, Funda Bayındır5.   

Abstract

PURPOSE: The accuracy of digital impressions is still controversial for complete arch implant cases. The aim of this study is to compare the accuracy of different intraoral scanners with the conventional technique in terms of trueness and precision in a complete arch implant model.
MATERIAL AND METHODS: Eight implants were inserted asymmetrically in a polyurethane edentulous mandibular model with different angulations. A 3-dimensional (3D) reference model was obtained by scanning this polyurethane model with an optical scanner. First, digital impressions were made by using 3 different intraoral scanners: Carestream 3500 (DC), Cerec Omnicam (DO) and 3Shape Trios 3 (DT). Subsequently, a nonsplinted open tray impression technique was used for conventional impression group (C) and then the master casts were digitalized with a lab scanner. Each 10 STL files belonging to 4 different impression groups were imported to a reverse engineering program, to measure distance and angle deviations from the reference model. All statistical analyses were performed after taking absolute values of the data. After comparing the impression groups with one-way ANOVA, the trueness and precision values were analyzed by Tukey post hoc test and 0.05 was used as the level of significance.
RESULTS: The mean trueness of distance was 123.06 ± 89.83 µm for DC, 229.72 ± 121.34 µm for DO, 209.75 ± 47.07 µm for DT, and 345.32 ± 75.12 µm for C group (p < 0.0001). While DC showed significantly lower deviation compared to DO and C, no significant difference was found between DC and DT. C showed the highest distance deviation significantly in all groups; and no significant difference was found between DO and DT groups. In angle measurements; the trueness was 0.26° ± 0.07° for DC, 0.53° ± 0.42° for DO, 0.33° ± 0.30° for DT, and 0.74° ± 0.65° for C group. There was no significant difference between the groups in terms of angular trueness (p = 0.074). In terms of the precision for distance, the results of DC 80.43 ± 29.69 µm, DO 94.06 ± 69.96 µm, DT 35.55 ± 28.46 µm and C 66.97 ± 36.69 µm were determined (p = 0.036). The significant difference was found only between DT and DO among all groups. Finally, angular precision was determined to be 0.19° ± 0.11° for DC, 0.30° ± 0.28° for DO, 0.22° ± 0.19° for DT, and 0.50° ± 0.38° for Group C. No significant difference was found between the groups, in terms of angular precision (p = 0.053).
CONCLUSIONS: All digital impression groups yielded superior data compared to conventional technique in terms of trueness. DC formed the impression group with the highest trueness in both distance and angular measurements. The results of this in vitro study suggest the use of intraoral scanners compared to the conventional impression techniques in complete arch implant cases with high angulations.
© 2020 by the American College of Prosthodontists.

Entities:  

Keywords:  Accuracy; angulated implants; complete arch; conventional implant impressions; digital implant impressions

Year:  2020        PMID: 32935894     DOI: 10.1111/jopr.13264

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  3 in total

1.  Reliability and Time Efficiency of Digital vs. Analog Bite Registration Technique for the Manufacture of Full-Arch Fixed Implant Prostheses.

Authors:  Philippe Nuytens; Rani D'haese; Stefan Vandeweghe
Journal:  J Clin Med       Date:  2022-05-19       Impact factor: 4.964

Review 2.  Accuracy of Digital Dental Implants Impression Taking with Intraoral Scanners Compared with Conventional Impression Techniques: A Systematic Review of In Vitro Studies.

Authors:  María Isabel Albanchez-González; Jorge Cortés-Bretón Brinkmann; Jesús Peláez-Rico; Carlos López-Suárez; Verónica Rodríguez-Alonso; María Jesús Suárez-García
Journal:  Int J Environ Res Public Health       Date:  2022-02-11       Impact factor: 3.390

3.  In Vivo Complete-Arch Implant Digital Impressions: Comparison of the Precision of Three Optical Impression Systems.

Authors:  Jaime Orejas-Perez; Beatriz Gimenez-Gonzalez; Ignacio Ortiz-Collado; Israel J Thuissard; Andrea Santamaria-Laorden
Journal:  Int J Environ Res Public Health       Date:  2022-04-03       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.