Literature DB >> 32933228

Minimally invasive search for a missing vibrator.

Greg J Marchand1, Ali Azadi2, Akarshi Kaue Brar2, Katelyn Sainz1,3, Sienna Anderson1, Stacy Ruther1, Kelly Ware1,3,4, Sophia Hopewell1, Giovanna Brazil1, Katerina Meassick3,5, Hannah Wolf1, Alexa King1, Jannelle Vallejo1,3, Kaitlynne Cieminski1, Anthony Galitsky1.   

Abstract

OBJECTIVE: To report a unique surgical procedure that was utilized to locate a missing vibrator in the pelvis of a patient. Emergency room admissions and surgery secondary to the malfunctioning of devices intended for sexual stimulation are extremely common. Emergency room staff of hospitals in the United States usually are skilled in the detection and removal of these devices. Occasionally, surgical intervention is warranted if the device enters a cavity that cannot safely be explored in the emergency room setting. We report a case of a vibrator that was lost during sexual activity. A flat plate X-ray showed it to be in the abdominal cavity. Careful questioning of the patient revealed that the device had an unusually small diameter. Surgical intervention showed that the device ultimately ended up in the bladder without causing traumatic injury.
METHODS: We created a narrated video to demonstrate the surgical procedure (Canadian Task Force Classification III).
RESULTS: Laparoscopy and cystoscopy were used to visualize and successfully remove the device. The patient recovered uneventfully.
CONCLUSION: Following laparoscopic confirmation of the location of the device, it was removed via cystoscopy. This case demonstrates how background information, such as the size of the missing device in this case, can be critical to providing high quality patient care.

Entities:  

Keywords:  Cystoscopy; Foreign bodies; Laparoscopy; Vibrator

Year:  2020        PMID: 32933228      PMCID: PMC7494772          DOI: 10.5468/ogs.20121

Source DB:  PubMed          Journal:  Obstet Gynecol Sci        ISSN: 2287-8572


In the United States, injuries from the use of sex-related instruments are a very common reason for emergency room visits [1,2]. Insertion of the instrument and its penetration through the vaginal wall regularly result in the object penetrating the abdominal cavity [3,4], leading to possible bowel damage. It is rare for large objects to enter and become trapped in the bladder [5]. A 29-year-old G1 Po Ab1 Caucasian woman visited the emergency room at about 1 A.M. and reported that her vibrator had become lost during sexual activity. The patient said that her partner suddenly started vaginal intercourse after using the vibrator to stimulate the clitoris directly. The patient was uncertain about the location of the vibrator and felt discomfort for a while. She thought the vibrator was in the vagina as sexual intercourse progressed because she could still feel the vibration. After intercourse, the patient could not find the vibrator in the vagina but still felt the sensation of vibration within the pelvis. When the patient was unable to find the vibrator, she presented to the emergency room. She stated that the vibration lasted about 30 minutes, approximately the battery life of the device. An X-ray of the pelvis showed that the vibrator was approximately at the level of the intrauterine device of the patient within pelvis and in the horizontal position. Careful questioning of the patient revealed that the vibrator was an unusual type called Vesper™ (Crave Corp., Bloomington, MN, USA), which has an unusually small diameter of approximately 1.2 cm. The device is approximately 10 cm long and on a chain to be worn like a necklace, maximizing the ease of use of the vibrator. The chain can be removed to use the vibrator for sexual activity. The patient confirmed that she removed the chain from the device before use. Repeated vaginal and rectal examinations by the emergency room staff and gynecologists did not show evidence of the device in either the vagina or the rectum, so it was assumed that the device passed through the vaginal wall and entered the abdominal cavity. The patient had a body mass index of 22.5, so it was believed that her weight did not affect the examinations. It was assumed that the colon had not ruptured because of the limited softness found on examination. However, before laparoscopic exploration, the patient agreed to undergo a colostomy and repair of the colon if found necessary. Laparoscopic exploration showed that the device was in the bladder. Its location was also demonstrated by moving a sponge stick placed in the vagina and by gently manipulating the poly bulb. The vibrator was visualized and removed with a cystoscope. To safely remove the vibrator through the urethra, it was necessary to fill the bladder with about 1 L of normal saline to change the orientation of the vibrator from horizontal to vertical, resulting in no morbidity from removal. The patient recovered without incident immediately after removal of the foreign body and was discharged from the hospital. To provide the highest level of care when treating a patient with a foreign body, it is important to understand, as much as possible, the object in question [6-8]. Most gynecologists are familiar with sex-related injuries and associated morbidities. In situations similar to that of our patient, most gynecologists generally assume that the vibrator will be too large to fit through the urethra [9-12]. In our case, the vibrator was measured to have an maximum diameter of about 1.2 cm, which is about the same as the diameter of a 36 French catheter. Thus, the device was able to enter the urethra and occupy the bladder without damaging it [13,14]. Another interesting aspect of this case was that the device was assumed to be in the pelvic cavity because it appeared on the X-ray to be approximately at the level of the intrauterine device. Retrospectively, we believe that if a computed tomography scan had been performed or a lateral X-ray taken, the radiologist might have been able to accurately locate the device. Thus, the patient could have been spared the laparoscopy because the device could have been removed with a simple cystoscopy.
  13 in total

1.  Vaginal vibrator lodged in rectum.

Authors:  J S Haft; H B Benjamin; M Wagner
Journal:  Br Med J       Date:  1976-03-13

Review 2.  Defining patterns of genital injury from sexual assault: a review.

Authors:  Marilyn Sawyer Sommers
Journal:  Trauma Violence Abuse       Date:  2007-07

Review 3.  Genital injuries in postmenopausal women after sexual assault.

Authors:  Christine A Poulos; Daniel J Sheridan
Journal:  J Elder Abuse Negl       Date:  2008

4.  Female victims of rape and their genital injuries.

Authors:  L Bowyer; M E Dalton
Journal:  Br J Obstet Gynaecol       Date:  1997-05

Review 5.  The (in)significance of genital injury in rape and sexual assault.

Authors:  Graeme Walker
Journal:  J Forensic Leg Med       Date:  2015-06-18       Impact factor: 1.614

6.  Female genital injuries resulting from consensual and non-consensual vaginal intercourse.

Authors:  Iain McLean; Stephen A Roberts; Cath White; Sheila Paul
Journal:  Forensic Sci Int       Date:  2010-05-31       Impact factor: 2.395

7.  Vaginal lacerations from consensual intercourse in adolescents.

Authors:  Sarah M Frioux; Thane Blinman; Cindy W Christian
Journal:  Child Abuse Negl       Date:  2011-01

8.  Patterns of genital injury in female sexual assault victims.

Authors:  L Slaughter; C R Brown; S Crowley; R Peck
Journal:  Am J Obstet Gynecol       Date:  1997-03       Impact factor: 8.661

9.  Genital injuries following sexual assault of women with and without prior sexual intercourse experience.

Authors:  M Biggs; L E Stermac; M Divinsky
Journal:  CMAJ       Date:  1998-07-14       Impact factor: 8.262

10.  Anogenital injuries in adolescents after consensual sexual intercourse.

Authors:  Jeffrey S Jones; Linda Rossman; Melissa Hartman; Carmen C Alexander
Journal:  Acad Emerg Med       Date:  2003-12       Impact factor: 3.451

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.