Literature DB >> 32929429

A new voltammetric platform for reliable determination of the sport performance-enhancing stimulant synephrine in dietary supplements using a boron-doped diamond electrode.

M Haššo1, O Sarakhman, D M Stanković, Ĺ Švorc.   

Abstract

For the first time, we propose a new modification-free voltammetric platform for simple, fast and reliable quantification of the sport performance-enhancing stimulant synephrine (SYN) based on the usage of a commercial screen-printed boron-doped diamond (BDD) electrochemical sensor. Applying cyclic voltammetry, SYN exhibited one well-shaped, irreversible and diffusion-driven oxidation peak at a peak potential of +1.45 V (vs. the silver pseudoreference electrode) in the presence of 2 M HClO4. Under the selected experimental conditions, the following analytical parameters for determination of SYN were obtained: linear concentration ranges from 19.6 up to 1000 μM and from 9.9 up to 1000 μM for differential pulse (DPV) and square-wave voltammetry (SWV), respectively, detection limits at micromolar concentration levels and intra-day repeatability with a relative standard deviation below 4% for both pulse techniques. The interference study revealed fair selectivity when considering the target dietary supplements. The feasibility of the developed voltammetric platform was verified in the analysis of commercially available dietary supplements and reasonable recovery values were achieved by DPV and SWV, respectively. In addition, the method can be performed directly without higher consumption of chemicals, waste generation, complex sample extraction and higher instrumentation cost. The advanced BDD electrochemical sensor has appeared to be a suitable competitor for efficient applications in food quality control analysis.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 32929429     DOI: 10.1039/d0ay01425g

Source DB:  PubMed          Journal:  Anal Methods        ISSN: 1759-9660            Impact factor:   2.896


  3 in total

Review 1.  Batch injection analysis in tandem with electrochemical detection: the recent trends and an overview of the latest applications (2015-2020).

Authors:  Marek Haššo; Ľubomír Švorc
Journal:  Monatsh Chem       Date:  2022-02-23       Impact factor: 1.451

2.  Electrochemical determination of synephrine by using nafion/UiO-66/graphene-modified screen-printed carbon electrode.

Authors:  Yi Zhang; Zongyi You; Liangliang Liu; Shengwen Duan; Aiping Xiao
Journal:  Curr Res Food Sci       Date:  2022-07-20

3.  The Safety and Efficacy of Citrus aurantium (Bitter Orange) Extracts and p-Synephrine: A Systematic Review and Meta-Analysis.

Authors:  Dorottya Koncz; Barbara Tóth; Muh Akbar Bahar; Orsolya Roza; Dezső Csupor
Journal:  Nutrients       Date:  2022-09-28       Impact factor: 6.706

  3 in total