Literature DB >> 32928419

A novel and ultrasensitive sandwich-type electrochemical immunosensor based on delaminated MXene@AuNPs as signal amplification for prostate specific antigen (PSA) detection and immunosensor validation.

Hilal Medetalibeyoglu1, Gül Kotan1, Necip Atar2, Mehmet Lütfi Yola3.   

Abstract

In this study, an ultra-sensitive electrochemical immunosensor for PSA detection was designed. Firstly, gold nanoparticles (AuNPs)/p-aminothiophenol (ATP) functionalized graphene oxide (GO) composite (AuNPs-ATPGO) was constructed and modified to glassy carbon electrode (AuNPs-ATPGO/GCE). AuNPs-ATPGO/GCE was utilized as immunosensor platform to increase the amount of PSA antibody1 (Ab1). After that, self-assembled delaminated MXene-gold nanoparticles (d-Ti3C2TX MXene@AuNPs) was used to label PSA seconder antibody2 (Ab2) as signal amplification. The prepared AuNPs-ATPGO, d-Ti3C2TX MXene@AuNPs and electrochemical immunosensor was charecterized by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), scanning electron microscope (SEM), x-ray diffraction (XRD) method, x-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM), fourier transform infrared spectroscopy (FTIR). The linearity range and detection limit (LOD) were obtained as 0.01-1.0 pg mL-1 and 3.0 fg mL-1, respectively.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Gold nanoparticles/graphene oxide composite; Immunosensor; Prostate-specific antigen (PSA); Validation; d-Ti(3)C(2)T(X) MXene@AuNPs

Mesh:

Substances:

Year:  2020        PMID: 32928419     DOI: 10.1016/j.talanta.2020.121403

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Electrochemical immunosensor with Cu2O nanocube coating for detection of SARS-CoV-2 spike protein.

Authors:  Zeinab Rahmati; Mahmoud Roushani; Hadi Hosseini; Hamzeh Choobin
Journal:  Mikrochim Acta       Date:  2021-03-02       Impact factor: 5.833

Review 2.  Advances and emerging challenges in MXenes and their nanocomposites for biosensing applications.

Authors:  Zaheer Ud Din Babar; Bartolomeo Della Ventura; Raffaele Velotta; Vincenzo Iannotti
Journal:  RSC Adv       Date:  2022-07-06       Impact factor: 4.036

Review 3.  Point-of-care electrochemical testing of biomarkers involved in inflammatory and inflammatory-associated medical conditions.

Authors:  Diana-Gabriela Macovei; Maria-Bianca Irimes; Oana Hosu; Cecilia Cristea; Mihaela Tertis
Journal:  Anal Bioanal Chem       Date:  2022-09-14       Impact factor: 4.478

4.  Sensitive sandwich-type voltammetric immunosensor for breast cancer biomarker HER2 detection based on gold nanoparticles decorated Cu-MOF and Cu2ZnSnS4 NPs/Pt/g-C3N4 composite.

Authors:  Mehmet Lütfi Yola
Journal:  Mikrochim Acta       Date:  2021-02-10       Impact factor: 5.833

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.