Literature DB >> 32926451

3D phase-resolved functional lung ventilation MR imaging in healthy volunteers and patients with chronic pulmonary disease.

Filip Klimeš1,2, Andreas Voskrebenzev1,2, Marcel Gutberlet1,2, Agilo Luitger Kern1,2, Lea Behrendt1,2, Robert Grimm3, Hendrik Suhling2,4, Cristian Gonzales Crisosto1,2, Till Frederick Kaireit1,2, Gesa Helen Pöhler1,2, Julian Glandorf1,2, Frank Wacker1,2, Jens Vogel-Claussen1,2.   

Abstract

PURPOSE: To test the feasibility of 3D phase-resolved functional lung (PREFUL) MRI in healthy volunteers and patients with chronic pulmonary disease, to compare 3D to 2D PREFUL, and to investigate the required temporal resolution to obtain stable 3D PREFUL measurement.
METHODS: Sixteen participants underwent MRI using 2D and 3D PREFUL. Retrospectively, the spatial resolution of 3D PREFUL (4 × 4 × 4 mm3 ) was decreased to match the spatial resolution of 2D PREFUL (4 × 4 × 15 mm3 ), abbreviated as 3Dlowres . In addition to regional ventilation (RVent), flow-volume loops were computed and rated by a cross-correlation (CC). Ventilation defect percentage (VDP) maps were obtained. RVent, CC, VDPRVent , and VDPCC were compared for systematic differences between 2D, 3Dlowres , and 3D PREFUL. Dividing the 3D PREFUL data into 4- (≈ 20 phases), 8- (≈ 40 phases), and 12-min (≈ 60 phases) acquisition pieces, the ventilation parameter maps, including the heterogeneity of ventilation time to peak, were tested regarding the required temporal resolution.
RESULTS: RVent, CC, VDPRVent , and VDPCC  presented significant correlations between 2D and 3D PREFUL (r = 0.64-0.94). CC and VDPCC  of 2D and 3Dlowres  PREFUL were significantly different (P < .0113). Comparing 3Dlowres  and 3D PREFUL, all parameters were found to be statistically different (P < .0045).
CONCLUSION: 3D PREFUL MRI depicts the whole lung volume and breathing cycle with superior image resolution and with likely more precision compared to 2D PREFUL. Furthermore, 3D PREFUL is more sensitive to detect regions of hypoventilation and ventilation heterogeneity compared to 3Dlowres  PREFUL, which is important for early detection and improved monitoring of patients with chronic lung disease.
© 2020 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  MRI; lung; thorax; ventilation

Mesh:

Year:  2020        PMID: 32926451     DOI: 10.1002/mrm.28482

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  A dual center and dual vendor comparison study of automated perfusion-weighted phase-resolved functional lung magnetic resonance imaging with dynamic contrast-enhanced magnetic resonance imaging in patients with cystic fibrosis.

Authors:  Lea Behrendt; Laurie J Smith; Andreas Voskrebenzev; Filip Klimeš; Till F Kaireit; Gesa H Pöhler; Agilo L Kern; Cristian Crisosto Gonzalez; Anna-Maria Dittrich; Helen Marshall; Katharina Schütz; Paul J C Hughes; Pierluigi Ciet; Harm A W M Tiddens; Jim M Wild; Jens Vogel-Claussen
Journal:  Pulm Circ       Date:  2022-04-05       Impact factor: 2.886

2.  PREFUL MRI Depicts Dual Bronchodilator Changes in COPD: A Retrospective Analysis of a Randomized Controlled Trial.

Authors:  Andreas Voskrebenzev; Till F Kaireit; Filip Klimeš; Gesa H Pöhler; Lea Behrendt; Heike Biller; Korbinian Berschneider; Frank Wacker; Tobias Welte; Jens M Hohlfeld; Jens Vogel-Claussen
Journal:  Radiol Cardiothorac Imaging       Date:  2022-04-21

3.  MRI lung lobe segmentation in pediatric cystic fibrosis patients using a recurrent neural network trained with publicly accessible CT datasets.

Authors:  Orso Pusterla; Rahel Heule; Francesco Santini; Thomas Weikert; Corin Willers; Simon Andermatt; Robin Sandkühler; Sylvia Nyilas; Philipp Latzin; Oliver Bieri; Grzegorz Bauman
Journal:  Magn Reson Med       Date:  2022-03-29       Impact factor: 3.737

4.  Reproducibility of functional lung parameters derived from free-breathing non-contrast-enhanced 2D ultrashort echo-time.

Authors:  Bingjie Yang; Patrick Metze; Anke Balasch; Kilian Stumpf; Meinrad Beer; Wolfgang Rottbauer; Volker Rasche
Journal:  Quant Imaging Med Surg       Date:  2022-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.