Literature DB >> 32925847

Comparing Cochlear Duct Lengths Between CT and MR Images Using an Otological Surgical Planning Software.

Nicholas A George-Jones1, Anthony M Tolisano2, J Walter Kutz1, Brandon Isaacson1, Jacob B Hunter1.   

Abstract

OBJECTIVE: We sought to examine the intra- and interobserver variability in measuring the cochlear duct length (CDL) from magnetic resonance imaging (MRI) images versus computed tomography (CT) images using an otological surgical planning software that uses measurements of the basal turn diameter and cochlear width to estimate the CDL. PATIENTS: Twenty-one adult cochlear implant patients with preoperative MRI and CT images. INTERVENTION: Three fellowship-trained neurotologists served as the raters in the study. One rater measured the CDL using preoperative CT scans to serve as the benchmark. Two of the raters measured the CDL on preoperative MRI scans. One rater also remeasured the scans using MRI images after a period of 1 week to assess intraobserver variability. MAIN OUTCOME MEASURE: Intraclass correlational coefficients were calculated to assess for intra- and interobserver agreement.
RESULTS: The mean CDL measured from the CT scans was 32.7 ± 2.0 mm (range 29.4 - 37.6 mm). The mean difference between the raters when measuring the CDL using MRI scans was -0.15 ± 2.1 mm (range -3.2 to 4.3 mm). The intraclass correlational coefficients for inter-rater reliability of CDL determination using MRI scans was judged as fair to excellent (0.68; 95% CI 0.41-0.84). The intrarater reliability of CDL determination using MRI scans was judged at fair to excellent (0.73; 95% CI 0.491-0.866).
CONCLUSION: We demonstrate that a validated otological surgical planning software for estimating the CDL preoperatively had comparable performance using MRI scans versus the gold-standard CT scans.

Entities:  

Mesh:

Year:  2020        PMID: 32925847     DOI: 10.1097/MAO.0000000000002777

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  5 in total

1.  Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques.

Authors:  Johannes Taeger; Franz Tassilo Müller-Graff; Lukas Ilgen; Phillip Schendzielorz; Rudolf Hagen; Tilman Neun; Kristen Rak
Journal:  OTO Open       Date:  2021-09-24

2.  Initial Hearing Preservation Is Correlated With Cochlear Duct Length in Fully-inserted Long Flexible Lateral Wall Arrays.

Authors:  Emily S Hollis; Michael W Canfarotta; Margaret T Dillon; Meredith A Rooth; Andrea L Bucker; Sarah A Dillon; Allison Young; Kristen Quinones; Harold C Pillsbury; Matthew M Dedmon; Brendan P O'Connell; Kevin D Brown
Journal:  Otol Neurotol       Date:  2021-09-01       Impact factor: 2.619

3.  Implementation of secondary reconstructions of flat-panel volume computed tomography (fpVCT) and otological planning software for anatomically based cochlear implantation.

Authors:  Franz-Tassilo Müller-Graff; Lukas Ilgen; Philipp Schendzielorz; Johannes Voelker; Johannes Taeger; Anja Kurz; Rudolf Hagen; Tilmann Neun; Kristen Rak
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-06-08       Impact factor: 3.236

4.  Application of intentional facial nerve stimulation during cochlear implantation as an electrophysiological tool to estimate the intracochlear electrode position.

Authors:  David P Herrmann; Franz-Tassilo Müller-Graff; Stefan Kaulitz; Mario Cebulla; Anja Kurz; Rudolf Hagen; Tilmann Neun; Kristen Rak
Journal:  Sci Rep       Date:  2022-08-04       Impact factor: 4.996

5.  [Measuring the cochlea using a tablet-based software package: influence of imaging modality and rater background].

Authors:  Lena Weber; Pingling Kwok; Erin M Picou; Christina Wendl; Christopher Bohr; Steven C Marcrum
Journal:  HNO       Date:  2022-08-15       Impact factor: 1.330

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.