MingXin Lin1, Cong Wang. 1. Ultrasound Department of the First Affiliated Hospital of Dalian Medical University, Dalian City, Liaoning Province, China.
Abstract
BACKGROUND: To compare superb microvascular imaging with power Doppler imaging for evaluating joint lesion scores in rheumatoid arthritis based on high quality clinical cohort or case control studies. METHODS: We searched Medline (via PubMed), Web of Science, Cochrane Library, Embase, and Chinese Biomedical Literature Database without restrictions of language and publication status. Two investigators will identify relevant trials, extract data, and appraise risk of bias in each eligible trial. Data will be pooled by either a fixed-effects model or a random-effects model according to the results of heterogeneity identification. The primary outcomes include a semi-quantitative scoring system, through which synovial vascularity intensity was evaluated by means of both power Doppler imaging (PDI) and superb microvascular imaging (SMI). This study will only include high quality clinical cohort or case control studies. Statistical analyses were conducted by STATA version 15.1 software. RESULTS: This meta-analysis included 11 studies. A total of 4342 joints were assessed through both SMI and PDI. The pooled summary odds ratio was 2.12 (95% confidence interval = 1.80-2.51) with statistical significance (z = 8.82, P < .01). In subgroup analyses, the results revealed also that SMI exhibited more sensitive performance in different subgroups. We found no evidence for publication bias (t = 0.55, P = .598). CONCLUSION: Our meta-analysis indicates that SMI ultrasound is more sensitive than conventional PDI in detecting synovitis in RA patients. INPLASY REGISTRATION NUMBER: INPLASY202060089.
BACKGROUND: To compare superb microvascular imaging with power Doppler imaging for evaluating joint lesion scores in rheumatoid arthritis based on high quality clinical cohort or case control studies. METHODS: We searched Medline (via PubMed), Web of Science, Cochrane Library, Embase, and Chinese Biomedical Literature Database without restrictions of language and publication status. Two investigators will identify relevant trials, extract data, and appraise risk of bias in each eligible trial. Data will be pooled by either a fixed-effects model or a random-effects model according to the results of heterogeneity identification. The primary outcomes include a semi-quantitative scoring system, through which synovial vascularity intensity was evaluated by means of both power Doppler imaging (PDI) and superb microvascular imaging (SMI). This study will only include high quality clinical cohort or case control studies. Statistical analyses were conducted by STATA version 15.1 software. RESULTS: This meta-analysis included 11 studies. A total of 4342 joints were assessed through both SMI and PDI. The pooled summary odds ratio was 2.12 (95% confidence interval = 1.80-2.51) with statistical significance (z = 8.82, P < .01). In subgroup analyses, the results revealed also that SMI exhibited more sensitive performance in different subgroups. We found no evidence for publication bias (t = 0.55, P = .598). CONCLUSION: Our meta-analysis indicates that SMI ultrasound is more sensitive than conventional PDI in detecting synovitis in RA patients. INPLASY REGISTRATION NUMBER: INPLASY202060089.
Rheumatoid arthritis (RA) is a chronic autoimmune disease characterized by polyarticular inflammation and pannus formation, leading to joint destruction and severe disability.[ Precise evaluation of synovial inflammation and bony deformity is very important for the management of RA, especially for early detection and evaluation of disease activity during follow-up.[ Serum Midkine, C reactive protein, and 28 joints-erythrocyte sedimentation rate score can be used as an inflammatory marker for detection of RA activity.[ The richness of pannus blood flow signals can reflect the severity of RA disease, so as to evaluate the development of RA disease.[ In tradition, power Doppler imaging (PDI) is used to detect the synovial vascularity, but because of the interference of tissue movement, it is not very sensitive to microvascular patterns and low blood flow velocity.[ Superb microvascular imaging (SMI) is a novel ultrasonic technology, which uses adaptive principle to display low-speed blood flow signal and several studies had suggested that SMI, as a promising alternative, can evaluate joint lesions in RA more sensitively comparable to PDI.[ However, the results of these studies have been contradictory and the sample sizes were small. Therefore, we performed the present meta-analysis to compare SMI with PDI for evaluating joint lesion scores in RA based on high quality clinical cohort or case control studies.
Methods
PROSPERO registration
This protocol has been reported based on the Preferred Reporting Items for Systematic Reviews and Meta-Analysis Protocol statement guidelines, and it has been registered in the INPLASY202060089.
Ethics and dissemination
No ethical approval is required in this study, because it will only analyze published data. It is supposed to be published on a peer reviewed journal or presented in a conference meeting.
Literature search
We searched Medline (via PubMed), Web of Science, Cochrane Library, Embase, and CBM databases without restrictions of language and publication status. The search strategy sample for PubMed is “Rheumatoid arthritis[Title/Abstract] AND superb microvascular imaging[Title/Abstract] AND power Doppler[Title/Abstract] (“2015/03/01”[PDat]: “2020/04/01”[PDat]).” We also reviewed references from eligible articles for additional relevant studies.Participants. Any patients who fulfilled the 2011 American College of Rheumatology/European League Against Rheumatism diagnosis criteria for RA will be included in spite of race, nationality, and sex.Intervention and comparison. All patients were assessed with SMI and PDI.Outcomes. The primary outcomes include a semi-quantitative scoring system, through which synovial vascularity intensity was evaluated by means of both PDI and SMI.Type of studies. This study will only include high quality clinical cohort or case control studies that compare SMI with PDI for evaluating joint lesion scores in RA.
Data extraction and quality assessment
Two investigators will independently extract the data from all included studies. The following data were extracted from each included research: year of article, the first author's surname, sample size, examination position, mean of disease activity score of 28 joints, Instrument. The quality of selected studies was independently evaluated according to a tool for the quality assessment of methodological index for nonrandomized studies (MINORS). The MINORS criteria included 12 assessment items. Each of these items was scored as “yes” (2), “no” (0), or “unclear” (1). MINORS score ranged from 0 to 24; and score ≥17 indicate a good quality. Any disagreements between 2 investigators will be solved through discussion or consultation by a 3rd investigator
Statistical analysis
The STATA version 15.1 software (Stata Corporation, College Station, TX) was used for meta-analysis. We calculated the pooled summary odds ratio (OR) and its 95% confidence interval (CI). The Cochran Q-statistic and I2 test were used to evaluate potential heterogeneity between studies. If Q test shows a P < .05 or I2 test exhibits > 50% which indicates significant heterogeneity, the random-effect model was conducted, or else the fixed-effects model was used. In order to evaluate the influence of single study on the overall estimate, sensitivity analysis was performed. We also performed sub group and meta-regression analyses to investigate potential sources of heterogeneity. The Begg funnel plot and Egger test were applied to assess the publication bias.[
Results
Characteristics of included studies
Initially, the searched keywords identified 55 articles. We reviewed the titles and abstracts of all articles and excluded 14 articles; full texts and data integrity were also reviewed and 30 were further excluded. Finally, 11 studies (Table 1) that met all inclusion criteria were included in this meta-analysis. Figure 1 showed the selection process of eligible articles. A total of 4342 joints were assessed through both SMI and PDI. MINORS scores of all included studies were more than or equal to 17.
Table 1
Baseline characteristics and methodological quality of all included studies.
Figure 1
Flow chart of literature search and study selection. Eleven studies were included in this meta-analysis.
Baseline characteristics and methodological quality of all included studies.Flow chart of literature search and study selection. Eleven studies were included in this meta-analysis.
Quantitative data synthesis
Sensitivity analysis was carried out, and none of them caused obvious interference to the results of this meta-analysis (Fig. 2). The pooled summary OR was 2.12 (95% CI = 1.80–2.51) with statistical significance (z = 8.82, P < .01), which indicated SMI was more sensitive for evaluating joint lesions in RA comparable to PDI (Fig. 3). In subgroup analyses, the results revealed that SMI exhibited more sensitive performance in different subgroups (Table 2, Fig. 4). Meta-regression analysis results confirmed that no factor could explain potential sources of heterogeneity (Table 3). The funnel plots indicated little evidence of significant publication bias (Fig. 5), and Egger test confirmed this (t = 0.55, P = .598).
Figure 2
Sensitivity analysis. None of them caused obvious interference to the results.
Figure 3
Forest plots of OR for SMI in the detection of pannus synovius comparable to PDI. OR = odds ratio, PDI = power Doppler imaging, SMI = superb microvascular imaging.
Table 2
Meta-analysis of SMI for evaluating RA comparing to PDI.
Figure 4
Subgroup analyses. SMI exhibited more sensitive performance in different subgroups. SMI = superb microvascular imaging.
Table 3
Meta-regression analyses of potential source of heterogeneity.
Figure 5
Begger funnel plot of publication bias on the pooled OR. No publication bias was detected in this meta-analysis. OR = odds ratio.
Sensitivity analysis. None of them caused obvious interference to the results.Forest plots of OR for SMI in the detection of pannus synovius comparable to PDI. OR = odds ratio, PDI = power Doppler imaging, SMI = superb microvascular imaging.Meta-analysis of SMI for evaluating RA comparing to PDI.Subgroup analyses. SMI exhibited more sensitive performance in different subgroups. SMI = superb microvascular imaging.Meta-regression analyses of potential source of heterogeneity.Begger funnel plot of publication bias on the pooled OR. No publication bias was detected in this meta-analysis. OR = odds ratio.
Discussion
PDI has high sensitivity to the examination of low velocity blood flow without angle dependence, and performs a good consistency with contrast enhanced ultrasound in the display of pannus in hyperplastic synovium of RA patients.[ SMI technology, based on the high-resolution Doppler technology, can identify the noise generated by blood flow and tissue movement, separate low-speed blood flow signals from filtered clutter signals, and display the real blood flow information.[ However, the relationship between SMI and PDI remains unclear. At present, there is a lack of multi center and large sample research in this aspect. In this meta-analysis, we compared SMI and PDI in detecting pannus synovius. The pooled summary OR was 2.12 with statistical significance, which strongly suggest that SMI ultrasound is more sensitive than conventional PDI in detecting synovitis in RA patients.However, several limitations still existed. First, the included studies were mainly performed in China, which may lead to selection bias due to ethnicity factors. Although existing systematic reviews have suggested that the inclusion of articles published in Chinese mainly would not affect the overall effect direction, the exclusion of publications in other languages may reduce the precision of the summary effect estimates.[ Second, many of the studies did not address whether the grades of SMI and PDI interacted with blinding. Empirical evidence suggests that lack of blinding tends to cause overestimation of the treatment effect.[ This indicates that even if bias is introduced by the lack of blinding, the true OR would be even smaller than the results generated by this meta-analysis. Thirdly, obvious heterogeneity may be due to differences sample size, examination position, mean of disease activity score of 28 joints. Furthermore, meta-analyses are retrospective studies, which may lead to subject selection bias. In future studies, large, multicenter, prospective, double-blind control studies are required to validate these findings.In conclusion, our meta-analysis suggests that SMI is more sensitive than PDI in detecting pannus synovius in RA patients. However, due to the limitations mentioned above, further detailed studies are still required to confirm our findings.
Authors: Andra Morrison; Julie Polisena; Don Husereau; Kristen Moulton; Michelle Clark; Michelle Fiander; Monika Mierzwinski-Urban; Tammy Clifford; Brian Hutton; Danielle Rabb Journal: Int J Technol Assess Health Care Date: 2012-04 Impact factor: 2.188
Authors: Laura A Rhodes; Ai Lyn Tan; Steven F Tanner; Aleksandra Radjenovic; Elizabeth M A Hensor; Richard Reece; Philip O'Connor; Paul Emery; Dennis McGonagle Journal: Arthritis Rheum Date: 2004-08
Authors: Charline Mourgues; Marie Blanquet; Laurent Gerbaud; Martin Soubrier; Maxime Dougados Journal: Joint Bone Spine Date: 2017-10-04 Impact factor: 4.929
Authors: Jelena Savović; Hayley E Jones; Douglas G Altman; Ross J Harris; Peter Jüni; Julie Pildal; Bodil Als-Nielsen; Ethan M Balk; Christian Gluud; Lise Lotte Gluud; John P A Ioannidis; Kenneth F Schulz; Rebecca Beynon; Nicky J Welton; Lesley Wood; David Moher; Jonathan J Deeks; Jonathan A C Sterne Journal: Ann Intern Med Date: 2012-09-18 Impact factor: 25.391
Authors: James Dale; David Purves; Alex McConnachie; Iain McInnes; Duncan Porter Journal: Arthritis Care Res (Hoboken) Date: 2014-01 Impact factor: 4.794