Literature DB >> 3292243

The use of 99mTc-DTPA for detection and localization of site of acute gastrointestinal bleeding.

H Abdel-Dayem1, K Mahajan, A Owuwanne, S Ericsson, K Nawaz, K Kouris, E Higazy, M Awdeh.   

Abstract

Intravenously injected 99mTc-DTPA was evaluated in 64 patients for its efficiency in detecting and localizing sites of acute upper and lower gastrointestinal (G.I.) bleeding. These studies were correlated with endoscopic and surgical findings. There were 34 bleeders and 30 non bleeders giving a sensitivity of 90%, specificity of 82% and accuracy of 86%. Of these, 49 were upper G.I. studies (stomach 21 and duodenum 28) and 15 were lower G.I. studies (small intestine 8, large bowel 7). Of the 49 upper G.I. studies, 27 showed active bleeding while 22 showed no bleeding at the time of the study resulting in a sensitivity of 87.5%, specificity of 76% and accuracy of 82%. Of the 15 lower G.I. studies, 7 were bleeders while 8 were non bleeders. All the lower G.I. bleeding sites were accurately localized with the 99mTc-DTPA. An incidental finding of these studies was the localization of 99mTc-DTPA in the site of inflammatory and malignant lesions of the G.I. tract. Of the 64 studies, 18 inflammatory and malignant lesions were detected with the IV injected 99mTc-DTPA; 10 were bleeders while 8 were non bleeders. Image subtraction of early from delayed images was helpful to differentiate bleeding from non bleeding cases in this last group of studies.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3292243     DOI: 10.1007/bf00253449

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  19 in total

1.  Detection of hemorrhage in a patient with cecal varices using 99mTc-sulfur colloid.

Authors:  J W Barry; C V Engle
Journal:  Radiology       Date:  1978-11       Impact factor: 11.105

2.  Tc 99m Na pertechnetate scanning of the abdomen with particular reference to small bowel pathology.

Authors:  D O Duszynski; T C Jewett; J E Allen
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1971-10

3.  False positive Meckel's diverticulum scan.

Authors:  T K Chaudhuri; J H Christie
Journal:  Surgery       Date:  1972-02       Impact factor: 3.982

4.  An experimental model for the detection and localisation of gastrointestinal bleeding using 99mTc-DTPA.

Authors:  A Owunwanne; K K Mahajan; S B Eriksson; H M Abdel-Dayem; M Awdeh
Journal:  Nuklearmedizin       Date:  1986-06       Impact factor: 1.379

5.  Evaluation of 99m Tc-DTPA for the measurement of glomerular filtration rate.

Authors:  J F Klopper; W Hauser; H L Atkins; W C Eckelman; P Richards
Journal:  J Nucl Med       Date:  1972-01       Impact factor: 10.057

6.  Technetium-99m DTPA: a new radiopharmaceutical for brain and kidney scanning.

Authors:  W Hauser; H L Atkins; K G Nelson; P Richards
Journal:  Radiology       Date:  1970-03       Impact factor: 11.105

7.  Detection of gastrointestinal bleeding with 99mTc-sulfur colloid.

Authors:  A Alavi
Journal:  Semin Nucl Med       Date:  1982-04       Impact factor: 4.446

8.  In vivo labeling of red blood cells with 99mTc: a new approach to blood pool visualization.

Authors:  D G Pavel; M Zimmer; V N Patterson
Journal:  J Nucl Med       Date:  1977-03       Impact factor: 10.057

9.  Radionuclide imaging of Meckel's diverticulum in children.

Authors:  M J Gelfand; E B Silberstein; J Cox
Journal:  Clin Nucl Med       Date:  1978-01       Impact factor: 7.794

10.  Image subtraction in acute gastrointestinal bleeding studies using 99Tcm-DTPA.

Authors:  K Kouris; H M Abdel-Dayem; M Awdeh
Journal:  Nucl Med Commun       Date:  1985-11       Impact factor: 1.690

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.