Literature DB >> 32921422

Effect of airborne-particle abrasion of a titanium base abutment on the stability of the bonded interface and retention forces of crowns after artificial aging.

João Pitta1, Felix Burkhardt2, Mustapha Mekki3, Vincent Fehmer4, Philippe Mojon5, Irena Sailer6.   

Abstract

STATEMENT OF PROBLEM: Published data have shown that a mechanical surface treatment of titanium surfaces increases bonding potential. However, most of the studies are based on shear or tensile tests performed on flat-surfaced specimens and do not take into consideration the retention given by the titanium base (ti-base) axial walls and the thermomechanical loading seen in a clinical setting.
PURPOSE: The purpose of this in vitro study was to evaluate the influence of different airborne-particle abrasion (APA) methods of the ti-base surface on the stability of the bonded interface and retention forces between these titanium bases and lithium disilicate crowns after thermomechanical aging.
MATERIAL AND METHODS: Sixty internal connection implants (Conelog) were restored with lithium disilicate crowns and bonded to the corresponding ti-bases (Conelog). The ti-bases were divided into 4 groups (n=15), 3 experimental groups applying different APA methods, 30-μm silica-modified Al2O3 particles (CoJet) (30-SiO-AlO), 50-μm Al2O3 (Cobra Aluoxyd) (50-AlO), 110-μm silica-modified Al2O3 particles (Rocatec Plus) (110-SiO-AlO), and 1 control group (NoT). Ti-bases were airborne-particle abraded (10 seconds, 0.25 MPa at a 10-mm distance) under standardized conditions in a custom-made APA device. All crowns were cemented with a resin cement (Multilink Hybrid Abutment). After aging (1 200 000 cycles, 49 N, 1.67 Hz; 5 °C-55 °C, 120 seconds), all specimens were assessed for the presence of bond failures by optical microscopy (×50). The retention forces (N) were tested by using a pull-off test (0.5mm/min). Modes of failure were classified (Type 1, 2, or 3). An additional ti-base representing each group was prepared for surface roughness (μm) calculation (Ra, Rc, Rz) with a noncontact laser profilometer, and representative scanning electron microscope (SEM) images were recorded (×1000). Chi-squared tests were performed to analyze the bonded interface failure and modes of failure, and a Kruskal-Wallis test was selected to evaluate retention force values (α=.05).
RESULTS: The percentages of bonding failure after aging were 73.3% (NoT), 40% (30-SiO-AlO), 6.7% (50-AlO), and 40% (110-SiO-AlO). The stability of the bonded interface was influenced by the APA method applied (P<.05). Mean ±standard deviation retention force values varied from 206.3 ±86.3 N (NoT) to 420 ±139.5 N (50-AlO), and the differences between these 2 groups were significant (P<.05). Modes of failure were predominantly Type 2 (30-SiO-AlO; 50-AlO; 110-SiO-AlO) and Type 3 (NoT).
CONCLUSIONS: Airborne-particle abrasion of the titanium surface increased the bond stability and retention forces between the ti-base and the respective crown. The use of 50-μm Al2O3 provided the most stable bonded interface among the different treatments.
Copyright © 2020 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2020        PMID: 32921422     DOI: 10.1016/j.prosdent.2020.06.013

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

1.  Evaluation of Er,Cr:YSGG laser irradiation for debonding of zirconia hybrid abutment crowns from titanium bases.

Authors:  Cemil Birand; Sevcan Kurtulmus-Yilmaz
Journal:  Lasers Med Sci       Date:  2022-03-07       Impact factor: 2.555

2.  Effect of surface treatment and luting agent type on shear bond strength of titanium to ceramic materials.

Authors:  Isil Karaokutan; Gulsum Sayin Ozel
Journal:  J Adv Prosthodont       Date:  2022-04-27       Impact factor: 1.989

3.  The Evaluation of Microshear Bond Strength of Resin Cements to Titanium Using Different Surface Treatment Methods: An In Vitro Study.

Authors:  Mohammadreza Nakhaei; Neda Bozorgmehr; Hamidreza Rajati Haghi; Hossein Bagheri; Abdolrasoul Rangrazi
Journal:  Biomimetics (Basel)       Date:  2022-01-20

4.  Bond strength of zirconia- or polymer-based copings cemented on implant-supported titanium bases - an in vitro study.

Authors:  Eliann Oddbratt; Lisa Hua; Bruno R Chrcanovic; Evaggelia Papia
Journal:  Biomater Investig Dent       Date:  2021-09-13

5.  Shear Bond Strength of Lithium Disilicate Bonded with Various Surface-Treated Titanium.

Authors:  Laongdao Amornwichitwech; Mali Palanuwech
Journal:  Int J Dent       Date:  2022-04-09

6.  The Effect of a 10-MDP-Based Dentin Adhesive as Alternative for Bonding to Implant Abutment Materials.

Authors:  Paula C K Carvalho; Cláudia C M S Almeida; Rodrigo O A Souza; Rubens Nisie Tango
Journal:  Materials (Basel)       Date:  2022-08-08       Impact factor: 3.748

7.  Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro.

Authors:  Felix Dähne; Heike Meißner; Klaus Böning; Christin Arnold; Ralf Gutwald; Elisabeth Prause
Journal:  Int J Implant Dent       Date:  2021-07-20
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.