Vasvi Singh1, Sarah Cuddy1, Marie F Kijewski1, Mi-Ae Park1, Alexandra Taylor1, Viviany R Taqueti1, Hicham Skali1, Ron Blankstein1, Rodney H Falk2, Marcelo F Di Carli1, Sharmila Dorbala3,4. 1. Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA, 02115, USA. 2. Cardiac Amyloidosis Program, Division of Cardiology, Department of Medicine, Heart & Vascular Center, Brigham and Women's Hospital and Harvard Medical School, Boston, MA, USA. 3. Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St, Boston, MA, 02115, USA. sdorbala@bwh.harvard.edu. 4. Cardiac Amyloidosis Program, Division of Cardiology, Department of Medicine, Heart & Vascular Center, Brigham and Women's Hospital and Harvard Medical School, Boston, MA, USA. sdorbala@bwh.harvard.edu.
Abstract
AIM: The purpose of this study was to determine the inter- and intra-observer variability in 99mtechnetium-pyrophosphate (99mTc-PYP) scan interpretation for diagnosis of transthyretin cardiac amyloidosis (ATTR). METHODS AND RESULTS: Our study cohort comprised 100 consecutive subjects referred for 99mTc-PYP imaging based on clinical suspicion of ATTR cardiac amyloidosis. Myocardial 99mTc-PYP uptake was assessed by both visual (comparison of myocardial to rib uptake) and semi-quantitative (heart-to-contralateral lung uptake ratio, H:CL) methods. Twenty scans were analyzed twice, at least 48 hours apart, by each of two independent observers. Patients with visual scores of ≥ 2 on planar imaging as well as myocardial uptake on SPECT/CT were classified as ATTR positive. Diagnosis of ATTR by visual 99mTc-PYP grade was perfectly reproducible [concordance: positive and negative scans 100% (53/53 and 47/47, respectively). Both inter- and intra-observer correlations for H:CL ratio (r2 = 0.90, 0.99 (Observer 1) and 0.98 (Observer 2), respectively) and repeatability values on Bland-Altman plots were excellent. The coefficient of variation (%) for Observers 1 and 2 was 3.21 (2.14 to 4.29) and 7.49 (4.95 to 10.09), respectively. In addition, there was 100% concordance in positive and negative scan interpretation by visual grading between novice CV imagers (< 3 years' experience) and an experienced CV imager (10 years' experience). CONCLUSIONS: This study showed excellent inter-observer reproducibility and intra-observer repeatability of 99mTc-PYP visual scan interpretation and H:CL ratio for diagnosis of cardiac ATTR amyloidosis. Cardiac ATTR amyloidosis can be diagnosed reliably using 99mTc-PYP SPECT/CT by novice and experienced CV imagers.
AIM: The purpose of this study was to determine the inter- and intra-observer variability in 99mtechnetium-pyrophosphate (99mTc-PYP) scan interpretation for diagnosis of transthyretin cardiac amyloidosis (ATTR). METHODS AND RESULTS: Our study cohort comprised 100 consecutive subjects referred for 99mTc-PYP imaging based on clinical suspicion of ATTR cardiac amyloidosis. Myocardial 99mTc-PYP uptake was assessed by both visual (comparison of myocardial to rib uptake) and semi-quantitative (heart-to-contralateral lung uptake ratio, H:CL) methods. Twenty scans were analyzed twice, at least 48 hours apart, by each of two independent observers. Patients with visual scores of ≥ 2 on planar imaging as well as myocardial uptake on SPECT/CT were classified as ATTR positive. Diagnosis of ATTR by visual 99mTc-PYP grade was perfectly reproducible [concordance: positive and negative scans 100% (53/53 and 47/47, respectively). Both inter- and intra-observer correlations for H:CL ratio (r2 = 0.90, 0.99 (Observer 1) and 0.98 (Observer 2), respectively) and repeatability values on Bland-Altman plots were excellent. The coefficient of variation (%) for Observers 1 and 2 was 3.21 (2.14 to 4.29) and 7.49 (4.95 to 10.09), respectively. In addition, there was 100% concordance in positive and negative scan interpretation by visual grading between novice CV imagers (< 3 years' experience) and an experienced CV imager (10 years' experience). CONCLUSIONS: This study showed excellent inter-observer reproducibility and intra-observer repeatability of 99mTc-PYP visual scan interpretation and H:CL ratio for diagnosis of cardiac ATTR amyloidosis. Cardiac ATTR amyloidosis can be diagnosed reliably using 99mTc-PYP SPECT/CT by novice and experienced CV imagers.