Literature DB >> 32917292

COVID-19 Outbreak Associated with Air Conditioning in Restaurant, Guangzhou, China, 2020.

Jianyun Lu, Zhicong Yang.   

Abstract

Entities:  

Keywords:  2019 novel coronavirus disease; COVID-19; China; SARS-CoV-2; droplet transmission; family cluster; outbreak; rebuttal; respiratory infections; restaurant; severe acute respiratory syndrome coronavirus 2; viruses; zoonoses

Mesh:

Year:  2020        PMID: 32917292      PMCID: PMC7588507          DOI: 10.3201/eid2611.203774

Source DB:  PubMed          Journal:  Emerg Infect Dis        ISSN: 1080-6040            Impact factor:   6.883


× No keyword cloud information.
In Response: We thank Prof. Rule () for her comments on our letter (). We welcome the opportunity to offer additional information on several of the points made. We wish to explain that although she stated that “‘The air outlet and the return air inlet for the central air conditioner were located above table C (Figure 1, panel B)’ does not describe the actual layout depicted in the figure, in which the air conditioner is located by table C and the exhaust fan is between tables B and D” (). In fact, the air outlet and the return air inlet for the central air conditioner were located above table C (Figure 1). The central air conditioner is constructed in 2 parts: air outlet and air inlet, indicating no discrepancy between the text and the figure.
Figure 1

Inlet and outlet of air conditioner described in study of COVID-19 outbreak associated with air conditioning in restaurant, Guangzhou, China, 2020 ().

Inlet and outlet of air conditioner described in study of COVID-19 outbreak associated with air conditioning in restaurant, Guangzhou, China, 2020 (). We agree that virus transmission in this outbreak could be explained by droplet transmission and the possibility that persons move around, touch surfaces, go to the restroom, or engage in other close contact. We considered these scenarios but omitted their mention in the research letter. Instead, we reported what we considered to be the most likely scenario, which is that the droplet transmission was prompted by the air blown from right to left and then across tables C, A, and B successively. The air movement facilitated dispersion of droplets containing severe acute respiratory syndrome coronavirus 2 (SARS-COV-2) from patient A1 to the 3 patients at table B. After the air had passed over tables C, A, and B, patients C1 and C2 acquired the infection from droplets mixed with SARS-COV-2 as they returned to the air inlet over table C. None of the 62 persons at the other 12 tables were infected, which suggests that the alternate scenarios (touching surfaces or going to the restroom at the same time) were less likely. Furthermore, some diners and waitresses also went to the restroom and were not infected. In addition, closed-circuit television tapes did not show that the patients in our study had gone to the restroom at the same time. The tapes showed that patient C1 walked in and out several times and passed table A on the way, which might be one of the reasons for the infection of patient C1. We did not describe the exhaust fan in the text, but we drew an exhaust fan between tables B and D in figure. To point out the exhaust fan, we drew it bigger than actual measurements, which were only 12 × 12 inches (305 mm × 305 mm); the fan was not strong enough to remove all air produced by the central air conditioner. After the initial publication, we revised the figure to show the appropriate size of the exhaust fan and added details about its size, emphasizing that the ventilation system was not well designed (Figure 2). The main air flow is discharged from the central air conditioning outlet and then returned to the air inlet. Because of the weak exhaust system, the ventilation in the restaurant was not good. We did not ignore the presence of the exhaust fan.
Figure 2

Air flow (A) and seating diagram (B) for restaurant described in study of COVID-19 outbreak associated with air conditioning in restaurant, Guangzhou, China, 2020 ().

Air flow (A) and seating diagram (B) for restaurant described in study of COVID-19 outbreak associated with air conditioning in restaurant, Guangzhou, China, 2020 (). We conclude that the air conditioner prompted transmission of SARS-CoV-2; the customers in the airflow were at high risk for infection with SARS-CoV-2 in the poorly ventilated environment. Because the staff and other diners were not exposed to the airflow mixed with SARS-CoV-2 transmitted by patient A1, their risk for infection was lower. We excluded the possibility of aerosol transmission (). It has been reported that aerosols (<5 μm) can remain in the air and disperse long distances (>1 m) (). The potential for aerosol transmission has been reported for severe acute respiratory syndrome coronavirus () and Middle East respiratory syndrome coronavirus (,). However, in our study, none of the 62 persons at the other 12 tables were infected. Moreover, the smear samples from the air conditioner were all negative by reverse transcription PCR. We believe that the most likely scenario for SARS-CoV-2 transmission in the restaurant was droplet transmission prompted by the air conditioning, although other scenarios are possible. The exhaust fan was not strong enough to modify the ventilation; the main mode of air circulation was the central air conditioning outlet with air returned to the air conditioning inlet. Because of the weak exhaust system, ventilation in the restaurant was poor. We recommend that air handling systems be sufficiently powered and maintained.
  6 in total

1.  A major outbreak of severe acute respiratory syndrome in Hong Kong.

Authors:  Nelson Lee; David Hui; Alan Wu; Paul Chan; Peter Cameron; Gavin M Joynt; Anil Ahuja; Man Yee Yung; C B Leung; K F To; S F Lui; C C Szeto; Sydney Chung; Joseph J Y Sung
Journal:  N Engl J Med       Date:  2003-04-07       Impact factor: 91.245

2.  Aerobiology and its role in the transmission of infectious diseases.

Authors:  Aaron Fernstrom; Michael Goldblatt
Journal:  J Pathog       Date:  2013-01-13

3.  COVID-19 Outbreak Associated with Air Conditioning in Restaurant, Guangzhou, China, 2020.

Authors:  Jianyun Lu; Jieni Gu; Kuibiao Li; Conghui Xu; Wenzhe Su; Zhisheng Lai; Deqian Zhou; Chao Yu; Bin Xu; Zhicong Yang
Journal:  Emerg Infect Dis       Date:  2020-04-02       Impact factor: 6.883

4.  Extensive Viable Middle East Respiratory Syndrome (MERS) Coronavirus Contamination in Air and Surrounding Environment in MERS Isolation Wards.

Authors:  Sung-Han Kim; So Young Chang; Minki Sung; Ji Hoon Park; Hong Bin Kim; Heeyoung Lee; Jae-Phil Choi; Won Suk Choi; Ji-Young Min
Journal:  Clin Infect Dis       Date:  2016-04-18       Impact factor: 9.079

5.  Potential Presymptomatic Transmission of SARS-CoV-2, Zhejiang Province, China, 2020.

Authors:  Zhen-Dong Tong; An Tang; Ke-Feng Li; Peng Li; Hong-Ling Wang; Jing-Ping Yi; Yong-Li Zhang; Jian-Bo Yan
Journal:  Emerg Infect Dis       Date:  2020-05-17       Impact factor: 6.883

6.  COVID-19 Outbreak Associated with Air Conditioning in Restaurant, Guangzhou, China, 2020.

Authors:  Ana M Rule
Journal:  Emerg Infect Dis       Date:  2020-09-11       Impact factor: 6.883

  6 in total
  5 in total

1.  Longitudinal analysis of built environment and aerosol contamination associated with isolated COVID-19 positive individuals.

Authors:  Patrick F Horve; Leslie G Dietz; Garis Bowles; Georgia MacCrone; Andreas Olsen-Martinez; Dale Northcutt; Vincent Moore; Liliana Barnatan; Hooman Parhizkar; Kevin G Van Den Wymelenberg
Journal:  Sci Rep       Date:  2022-05-05       Impact factor: 4.996

2.  Susceptibility to Severe Acute Respiratory Syndrome Coronavirus 2 Infection Among Children and Adults: A Seroprevalence Study of Family Households in the Barcelona Metropolitan Region, Spain.

Authors:  Pedro Brotons; Cristian Launes; Elena Buetas; Vicky Fumado; Desiree Henares; Mariona Fernandez de Sevilla; Alba Redin; Laura Fuente-Soro; Daniel Cuadras; Maria Mele; Cristina Jou; Pere Millat; Iolanda Jordan; Juan Jose Garcia-Garcia; Quique Bassat; Carmen Muñoz-Almagro
Journal:  Clin Infect Dis       Date:  2021-06-15       Impact factor: 9.079

3.  Using high-resolution contact networks to evaluate SARS-CoV-2 transmission and control in large-scale multi-day events.

Authors:  Rachael Pung; Josh A Firth; Lewis G Spurgin; Vernon J Lee; Adam J Kucharski
Journal:  Nat Commun       Date:  2022-04-12       Impact factor: 14.919

4.  Expansion of droplets during speaking and singing in Japanese.

Authors:  Hideaki Kato; Ryuta Okamoto; Sohei Miyoshi; Sho Noguchi; Masakazu Umeda; Yuhei Chiba
Journal:  PLoS One       Date:  2022-08-25       Impact factor: 3.752

5.  A systematic review and meta-analysis of indoor bioaerosols in hospitals: The influence of heating, ventilation, and air conditioning.

Authors:  Rongchen Dai; Shan Liu; Qiushuang Li; Hanting Wu; Li Wu; Conghua Ji
Journal:  PLoS One       Date:  2021-12-23       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.