Literature DB >> 32914987

Plasmonic and Electrostatic Interactions Enable Uniformly Enhanced Liquid Bacterial Surface-Enhanced Raman Scattering (SERS).

Loza F Tadesse1, Chi-Sing Ho2,3, Dong-Hua Chen4, Hamed Arami5, Niaz Banaei6,7,8, Sanjiv S Gambhir1,3,5,9, Stefanie S Jeffrey10, Amr A E Saleh3,11, Jennifer Dionne3,5.   

Abstract

Surface-enhanced Raman spectroscopy (SERS) is a promising cellular identification and drug susceptibility testing platform, provided it can be performed in a controlled liquid environment that maintains cell viability. We investigate bacterial liquid-SERS, studying plasmonic and electrostatic interactions between gold nanorods and bacteria that enable uniformly enhanced SERS. We synthesize five nanorod sizes with longitudinal plasmon resonances ranging from 670 to 860 nm and characterize SERS signatures of Gram-negative Escherichia coli and Serratia marcescens and Gram-positive Staphylococcus aureus and Staphylococcus epidermidis bacteria in water. Varying the concentration of bacteria and nanorods, we achieve large-area SERS enhancement that is independent of nanorod resonance and bacteria type; however, bacteria with higher surface charge density exhibit significantly higher SERS signal. Using cryo-electron microscopy and zeta potential measurements, we show that the higher signal results from attraction between positively charged nanorods and negatively charged bacteria. Our robust liquid-SERS measurements provide a foundation for bacterial identification and drug testing in biological fluids.

Entities:  

Keywords:  bacteria; cryo-electron microscopy; gold nanorods; infectious disease; surface-enhanced Raman spectroscopy (SERS)

Mesh:

Substances:

Year:  2020        PMID: 32914987      PMCID: PMC7564787          DOI: 10.1021/acs.nanolett.0c03189

Source DB:  PubMed          Journal:  Nano Lett        ISSN: 1530-6984            Impact factor:   11.189


Rapid bacterial detection, identification, and antibiotic susceptibility testing is a critical clinical challenge. Standard bacterial diagnostics requires culturing steps that are naturally slow, accompanied by separate identification and antibiotic susceptibility tests that together span several days.[1] Molecular diagnostic tools such as polymerase chain reaction (PCR),[2] matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF),[3] and lateral flow enzyme immunoassays (EIA)[4,5] can expedite the process but still require hundreds of thousands of cells, significant capital investment, and/or cell-specific labels for high-fidelity testing; they are also destructive tests and hence are ill-suited for real-time drug susceptibility testing. Vibrational spectroscopy-based approaches such as Raman and Infrared spectroscopy promise culture-free, label-free, fast, accurate, and sensitive identification of bacteria with minimal sample preparation and without significant cell damage.[6−11] These techniques provide a spectroscopic fingerprint of bacterial cells, with signal enhancements afforded by plasmonic substrates via either surface-enhanced Raman spectroscopy (SERS) or infrared absorption spectroscopy (SEIRA).[12−15] For portable, low-cost diagnostics, SERS has gained particular traction: the visible-frequency excitation and detection of SERS allows single-cell-level[16] sensitivity as well as cheaper detectors and light sources. Further, its integration with microfluidics[17−19] along with the development of paper-based SERS assays[20] and portable Raman microscopes[21] increases its accessibility for clinical application.[22] Still, although considerable advances in the field of bacteria identification with SERS have been shown, many studies to date use dried samples because of the ease of sample preparation and spectral acquisition.[17,23] In contrast, clinical samples are generally in the liquid state, as drying can be detrimental to the cells, removes or modifies important biological information from the SERS spectra, and does not allow dynamic study on the effect of antibiotics on bacterial cells. Although clinically desirable, liquid Raman measurements present several challenges. Scattering from the inhomogeneous bacterial liquid with variations in dielectric constants leads to signal loss. Liquid SERS also requires devising easy-to-use and safe (i.e., free of hazardous bacterial exposure) platforms with optically compatible components. Efforts have been made to enable SERS measurements from liquid droplets on substrates.[24−26] However, the droplets were open to air, increasing the risk of aerosol/droplet exposure to the individuals performing measurements on pathogenic bacteria. Additionally, droplets tend to dry over a period of minutes, possibly providing insufficient interrogation time for bacteria identification and especially antibiotic susceptibility testing. This approach also limits the number of cells that can be analyzed to the size of the droplet. Microfluidic approaches[18,27−32] have gained traction in advancing liquid SERS; here, the flow rate even at the single-cell level can be synchronized with the Raman signal acquisition for achieving targeted cell sorting, as demonstrated in yeast strains Saccharomyces cerevisiae.[33] This approach, however, can only handle small sample volumes. Additionally, the strong Raman background from the commonly used PDMS material interferes with weak Raman signals from smaller cell types like bacteria compared to yeast. Moreover, for all existing liquid SERS approaches, there remains the need to understand and optimize plasmonic particle and bacterial cell interaction for efficient, uniform SERS enhancement. Here we demonstrate a liquid bacterial SERS platform with consistent, large-area SERS enhancement. In particular, we investigate the effects of bacterial surface charge, the gold–nanorod aspect ratio, and nanoparticle concentration to systematically determine the optimal parameters for liquid SERS. We use Gram-negative E. coli and S. marcescens and Gram-positive S. aureus and S. epidermidis as model bacteria to study their interaction with gold nanorods. By optimizing the nanorod to bacteria concentration ratios, we obtain SERS signatures from liquid bacteria samples with signal intensities uniformly enhanced to detectable levels (compared to no signal with bacteria in water) across a 100 × 200 μm2 area. Interestingly, the enhancement does not significantly vary with distinct nanorod aspect ratios, regardless of overlap with the laser excitation and Raman region of the bacteria; however, Gram-positive bacteria do show more significant enhancement. Cryo-electron microscopy (cryo-EM) reveals variations in nanoparticle binding affinities to Gram-positive and -negative bacterial types, depending on the charge of the bacteria membrane. As such, the bacteria with higher surface charge density also exhibit significantly higher SERS signal. Our work lays a foundation for performing, optimizing, and understanding liquid SERS measurements from biological fluids en route to clinical SERS and real-time drug susceptibility testing. We created a liquid chamber (hereafter “well”) for live bacterial SERS measurements as shown in Figure a. The well consists of a silicon wafer base, ∼100 μm tall spacer layer, and glass coverslip; double-sided adhesive was used for the spacer layer, punched using single paper hole punchers to create reproducible liquid well sizes. The liquid bacterial sample is pipetted into the well, then sealed with a coverslip and placed on a microscope stage for SERS imaging. Gold nanorods with longitudinal plasmon resonances ranging from 670–860 nm, governed by their aspect ratio, were colloidally synthesized via a seeded growth: reduction of HAuCl4 with sodium borohydride creates a spherical seed solution. The seed solution and additional gold salt is mixed with AgNO3, HCl, ascorbic acid, hexadecyl(trimethyl)ammonium bromide (CTAB), and sodium oleate for nanorod formation (see Figure S1). The target aspect ratio is controlled by the concentrations of each agent, as described in the literature.[34] All nanorods are coated with sodium oleate and CTAB, giving them a slightly positive charge, as confirmed by zeta potential measurements (see the Figure S11). UV–vis absorption spectra (Figure b) and transmission and scanning electron micrographs (TEM and SEM) of the gold nanorod samples (Figure c) confirm the red-shifting of the longitudinal plasmon resonance peak with increasing aspect ratio.
Figure 1

Overview of liquid-SERS chamber and plasmonic nanoparticles employed. (A) Liquid well imaging setup with bacteria (green) and nanorods (gold) both suspended in water and mixed together in the well. The well is fabricated using a Si wafer base and a double-sided adhesive spacing layer and sealed with a coverslip (see also Figure S15). (B) Absorption spectra of nanorods in the liquid well with longitudinal plasmon resonances ranging from 670–860 nm. Inset shows aspect ratios plotted against peak resonance wavelength. The dashed line indicates the 785 nm incident laser used for measurement. The region from ∼835–915 nm (annotated with redline) represents the bacterial Raman shift region. (C) TEM (left) and SEM (right) of synthesized gold nanorod particles used for liquid SERS measurement, showing monodispersity in nanorod size and shape. Additional images are included in Figure S1.

Overview of liquid-SERS chamber and plasmonic nanoparticles employed. (A) Liquid well imaging setup with bacteria (green) and nanorods (gold) both suspended in water and mixed together in the well. The well is fabricated using a Si wafer base and a double-sided adhesive spacing layer and sealed with a coverslip (see also Figure S15). (B) Absorption spectra of nanorods in the liquid well with longitudinal plasmon resonances ranging from 670–860 nm. Inset shows aspect ratios plotted against peak resonance wavelength. The dashed line indicates the 785 nm incident laser used for measurement. The region from ∼835–915 nm (annotated with redline) represents the bacterial Raman shift region. (C) TEM (left) and SEM (right) of synthesized gold nanorod particles used for liquid SERS measurement, showing monodispersity in nanorod size and shape. Additional images are included in Figure S1. We varied the bacteria and Au nanorod mixing ratio and preparation conditions to obtain maximally enhanced SERS signatures while keeping the bacteria viable. Importantly, because the CTAB surfactant from the gold nanorods is cytotoxic, we tested the number of water washing steps needed for aggregation-free nanoparticle dispersion with minimal surfactant coverage to preserve bacterial cell viability. Figures S2 and S3 include bacterial growth/viability tests following mixing with nanorods (NRs) that are not purified with water and purified with water at 1, 2, and 3× washing. We find that cell viability is maintained with one washing step, as evidenced by cell growth; additional washing steps lead to comparable bacterial viability but significant nanorod aggregation. We also investigated the concentration of nanorods to bacteria, spanning 10, 30, 50, and 100% (double volume of nanorod to bacteria) volumetric ratios. As shown in Figure S2 and Table S2, all ratios maintain cell viability and show significant SERS, with the highest signal generally observed for the largest ratio. Hence, a 1:1 volumetric ratio (5 μL of 1 × 109 cells/mL bacteria with 5 μL of NR) is used for ease of experimental workflow. Using a 785 nm laser, we obtained strongly enhanced SERS signatures from the liquid wells with bacteria and nanorods compared to bacteria-only samples. All measurements are obtained using a 5×, 0.12NA objective lens with a 30 μm focal spot and experimental conditions chosen to maximize translation to point-of-care clinical applications (i.e., portable, low-cost systems). Figure a includes representative SERS spectra from E. coli suspended in water (∼1 × 109 cells/mL, from log-phase of bacteria culture) showing the significant Raman signal enhancement achieved in liquid samples when mixed with nanorods compared to E. coli only. Figure b shows the average spectra, each collected with 10 s acquisition time, from the four bacterial species E. coli, S. marcescens, S. aureus and S. epidermidis, respectively. With the 670 nm resonant nanorods, bacterial signature spectral peaks near 1000, 1350, and 1500 cm–1 are observed. The liquid-SERS signatures are nearly identical with the SERS signatures seen with dried specimens;[23] we note that in both dried and liquid cases, the SERS results from a combination of cellular structures (membrane proteins, lipids, and intracellular components) as well as excreted metabolites (including metabolites resulting from stress responses to nutrient-poor aqueous media, as in our well).[19] As Figure a, b shows, spectra from the samples without nanorods have no signal under the same interrogation settings; hence detectable spectra are attributed to enhancement from nanorods (see Figure S4).
Figure 2

Spectral enhancement consistency across a large surface area of the well and among multiple liquid-SERS chambers. (A) Comparison of E. coli Raman spectra with and without the 670 nm nanorods, acquired at 60 s with 5 accumulation, showing no significant spectral signature from liquid E. coli samples without nanorods. (B) Liquid-SERS spectra of the four bacterial species mixed with the 670 nm nanorods with the average and standard deviation of 15 measurements at 10 s acquisition across 100 × 200 μm2 dimension on the well (inset in C). (C) Heatmap plot of the S. epidermidis spectra shown in B highlighting the consistency of enhancements across the large area. Each row is a spectrum recorded from unique locations on the well. The inset is a schematic showing the xy map region scanned on the liquid well.

Spectral enhancement consistency across a large surface area of the well and among multiple liquid-SERS chambers. (A) Comparison of E. coli Raman spectra with and without the 670 nm nanorods, acquired at 60 s with 5 accumulation, showing no significant spectral signature from liquid E. coli samples without nanorods. (B) Liquid-SERS spectra of the four bacterial species mixed with the 670 nm nanorods with the average and standard deviation of 15 measurements at 10 s acquisition across 100 × 200 μm2 dimension on the well (inset in C). (C) Heatmap plot of the S. epidermidis spectra shown in B highlighting the consistency of enhancements across the large area. Each row is a spectrum recorded from unique locations on the well. The inset is a schematic showing the xy map region scanned on the liquid well. Next, we collected SERS spectra across a 100 × 200 μm2 region within our liquid well. Again, using our 670 nm resonant nanorods, we obtain uniform Raman signal enhancement for each of the four bacteria, as shown in Figure c and Figure S5. Importantly, the peak signals vary by ∼25% across the entire scanned area, which is reasonable given the size of the area scanned and the large spot size of 30 μm. We also tested the well-to-well reproducibility by using S. epidermidis mixed with our 860 nm resonant nanorods. As seen in Figure S6, each liquid well shows comparable spectral enhancement with the mean of measurements across the 100 × 200 μm2 area across five separate wells with a variation of ∼15%. We explored how each nanorod with specific longitudinal plasmon resonance peaks enhances the liquid SERS signals. We considered the five NRs of Figure b and constructed 30 distinct liquid wells, each containing 1:1 bacteria:NR volumetric ratio mixtures. These NR aspect ratios are chosen such that their peak plasmon resonance wavelength spans the relevant optical ranges for SERS including incident illumination (785 nm) and the bacterial Raman shift region (∼835–915 nm). As seen in Figure , all NR samples show strong SERS signatures. Interestingly, the NR-to-NR variability in signal is comparable to the well-to-well signal variability (see Figure S6) for a given aspect ratio and bacteria sample. Therefore, within the error of these measurements, all NRs show strong enhancement.
Figure 3

SERS spectra comparison across nanorods and bacteria. (A) S. epidermidis spectra combined with the five NRs, color coded and arranged such that the most blue-shifted is on top and most red-shifted at the bottom. (B) S. aureus, (C) E. coli, and (D) S. marcescens SERS spectra when mixed with the five nanorods tested. (E) Area under the peak values for signature bacterial peaks near 1000, 1300, and 1500 cm–1 showing higher values for S. epidermidis and S. aureus, which have higher negative surface charge compared to E. coli and S. marcescens. The bar plots shown are for the 670 and 863 nm resonant nanorods (see Figure S9.

SERS spectra comparison across nanorods and bacteria. (A) S. epidermidis spectra combined with the five NRs, color coded and arranged such that the most blue-shifted is on top and most red-shifted at the bottom. (B) S. aureus, (C) E. coli, and (D) S. marcescens SERS spectra when mixed with the five nanorods tested. (E) Area under the peak values for signature bacterial peaks near 1000, 1300, and 1500 cm–1 showing higher values for S. epidermidis and S. aureus, which have higher negative surface charge compared to E. coli and S. marcescens. The bar plots shown are for the 670 and 863 nm resonant nanorods (see Figure S9. The lack of trend in enhancement factor with NR aspect ratio (peak plasmon resonance) counters standard intuition from dried SERS measurements. In liquids, the nanorods are fairly uniformly distributed throughout the liquid volume. Hence, both incident and scattered light strongly interact with the nanorods as light travels across the liquid volume beyond the measurement plane. This interaction becomes particularly strong when the nanorod resonance overlaps with either the excitation wavelength or the bacteria Raman scattering wavelengths. Accordingly, a “competition between extinction and enhancement” effect as described by van Dijk et al. and Sivapalan et al.[35,36] arises, compromising the expected higher enhancement at these wavelengths. On the contrary, when the NR resonance is blue-shifted away from these regions of strong competition, the overall setup shows a relatively higher enhancement profile. Interestingly, higher counts are observed for the NR with the lowest aspect ratio, most blue-shifted from the laser excitation (see Figure S7). Such enhancements have also been corroborated by other liquid-SERS studies on trap-coated methylene blue molecules and attributed to reduced extinction effects. As discussed above, when using nanorods with resonances matched to the incident laser or the Raman region, both the laser and the Raman scattered light are absorbed by the nanoparticles themselves before reaching the bacterial cells and the detector, respectively. However, when using blue-shifted nanorods, these extinction effects are avoided.[35,36] Still, within the variability of multiple measurements from distinct wells, we have not observed a statistically significant difference for SERS from rods of any size. In addition, it can be seen from Figure that the most red-shifted nanorods still contribute to signal enhancement significantly in S. epidermidis and S. aureus cases. Our results indicate that all nanorod aspect ratios provide significant enhancement for recording SERS signatures from liquid bacterial samples compared to bacteria-only samples suspended in water (see Figure S4). Gram-positive and highly negatively charged S. epidermidis and S. aureus overall show more distinct, higher intensity spectra than the Gram-negative E. coli and S. marcescens species. Specifically, S. marcescens shows consistent reduced spectral signal intensity across the nanorods tested and multiple trials while E. coli tends to be lower or comparable in repeat studies (see Figure S8). In our study the selected Gram-negative species harbor lower negative surface charge, with E. coli and S. marcescens having negative surface charge densities of ∼0.01 and ∼0.04 (r/e (−)/(1 × 10–6) mm2), respectively, whereas the Gram-positive S. epidermidis and S. aureus have negative surface charge densities of ∼1 and ∼0.3 (r/e (−)/(1 × 10–6) mm2). S. epidermidis, in particular, has nearly two orders of magnitude higher negative charge density which could significantly contribute to stronger electrostatic interactions with the positively charged nanorods (see also Table S1). Figure e illustrates the higher enhancement observed in higher surface charge harboring species. We plot the integrated intensity for spectral peaks near 1000, 1300, and 1500 cm–1 wavenumbers for two sets of nanorods (additional nanorod SERS data is in Figure S9). Across all nanorods, significantly higher SERS signal is observed for S. epidermidis and S. aureus, which have higher negative surface charge compared to E. coli and S. marcescens. To better understand the local interaction between the cells and NRs in our liquid well, we performed cryo-EM. We froze our liquid bacteria–NR mixture onto a 200-mesh Cu lacey carbon grid to image the nanorod distribution on the bacteria as-is in liquid (see Figure S10 of dried SEM images). We imaged with a low dose at −177 °C. The cryo-EM images show distinct differences in the arrangement of NRs around Gram-negative and Gram-positive bacteria. As seen in Figure , the NRs surround Gram-positive S. epidermidis by closely binding to its membrane surface, whereas in the case of Gram-negative E. coli, the nanorods do not show specific adherence to the bacterial membrane surface. The observed close binding is because of the positive surface charge of the NRs (resulting from the CTAB surfactant on their surface, confirmed by the zeta-potential measurements shown on Figure S11) interacting with the negative surface charge on the bacterial membrane. In particular, S. epidermidis has ∼30× higher negative charge with significantly smaller surface area compared to E. coli (see Table S1). The large charge distributed over a small surface area allows S. epidermidis to have nearly two orders of magnitude higher charge density than E. coli, resulting in a stronger electrostatic interaction with the positively charged NRs.
Figure 4

Interaction between bacterial cells and nanoparticles and its effect on Raman signal enhancement. Cryo-EM images of S. epidermidis (left column) mixed with three NRs with longitudinal plasmon resonance peaks and color coding: (A) 670 nm, purple; (B) 717 nm, green; and (C) 860 nm, red, respectively. Similarly, E. coli (right column) mixed with three NRs with longitudinal plasmon resonance peaks and color coding: (D) 670 nm, purple; (E) 717 nm, green; and (F) 860 nm, red, respectively. The nanoparticles show tight binding to S. epidermidis cell surface compared to E. coli cell surfaces, as the former has a higher negative surface charge. Scale bar indicates 500 nm.

Interaction between bacterial cells and nanoparticles and its effect on Raman signal enhancement. Cryo-EM images of S. epidermidis (left column) mixed with three NRs with longitudinal plasmon resonance peaks and color coding: (A) 670 nm, purple; (B) 717 nm, green; and (C) 860 nm, red, respectively. Similarly, E. coli (right column) mixed with three NRs with longitudinal plasmon resonance peaks and color coding: (D) 670 nm, purple; (E) 717 nm, green; and (F) 860 nm, red, respectively. The nanoparticles show tight binding to S. epidermidis cell surface compared to E. coli cell surfaces, as the former has a higher negative surface charge. Scale bar indicates 500 nm. We also confirmed no significant change in the full-width half max and plasmon peak location (there is a slight red shift with addition of bacteria which can be attributed to the slight increase in refractive index of the solution) of the nanorods when mixed with the bacteria species (see supplemental Figure 12). Interestingly, the spectral data from three isolated trials comparing the SERS enhancement for S. epidermidis and E. coli do not show statistically significant differences upon repeated measurements as shown in Figure S13. Therefore, although differences in surface charge lead to different NR coverage on individual bacterial cells and thus variations in enhancement, the NRs still effectively enhance the overall SERS signal as the NRs and cells can freely interact in the dynamic liquid environment. Furthermore, bacterial NR mixtures were measured within a few minutes, after 5 h, and after 24 h and were tested and show new peaks arising near 1600 cm–1 with time (24 h), which can be attributed to cellular death showing the potential use of such liquid wells for monitoring live cell changes across time, see Figure S14. In summary, we have demonstrated a simple and robust liquid Raman well setup that enables uniform, large-area SERS enhancement of bacteria in liquid while maintaining cell viability and prevents exposure to pathogenic bacteria under investigation. Our results show that bacteria with higher negative surface charge better attract the positively charged Au NRs, leading to higher SERS enhancements. Furthermore, several NRs with longitudinal plasmon resonance peaks ranging from 670 to 870 nm can be used to obtain SERS enhancements despite the differences in peak location. Our work could facilitate clinical translation of Raman-based diagnostics. For example, in the realm of antibiotic testing, combination therapy is gaining traction as a more effective treatment approach compared to single antibiotic treatments;[37] a reliable liquid-SERS environment integrated with inflow and outflow channels could be used to test the effect of combined antibiotic therapy on pathogens by monitoring dynamic changes in the bacteria directly from Raman spectral changes. Liquid-SERS could also enable real-time drug susceptibility testing on cancer cells, without the need for fixing or freezing of the cells, potentially at the single-cell level. Additionally, liquid SERS could enable viable bacterial identification at low concentrations, which is especially important for bacteria that are difficult to culture, such as in microbiome studies and environmental microbiology.[38] Lastly, in pharmaceutical applications such as drug discovery, liquid-SERS could be used to monitor chemical composition of excreted factors in combined cultures while maintaining cellular viability.[39,40] Our simple sample preparation platform and rigorous understanding of liquid bacterial SERS hopefully provides a foundation for such studies and more en route to low-cost point-of-care diagnostics.
  33 in total

1.  Micro-Raman spectroscopic identification of bacterial cells of the genus Staphylococcus and dependence on their cultivation conditions.

Authors:  M Harz; P Rösch; K-D Peschke; O Ronneberger; H Burkhardt; J Popp
Journal:  Analyst       Date:  2005-09-30       Impact factor: 4.616

2.  SERS detection of bacteria in water by in situ coating with Ag nanoparticles.

Authors:  Haibo Zhou; Danting Yang; Natalia P Ivleva; Nicoleta E Mircescu; Reinhard Niessner; Christoph Haisch
Journal:  Anal Chem       Date:  2014-01-14       Impact factor: 6.986

3.  Raman spectroscopic identification of single bacterial cells under antibiotic influence.

Authors:  Ute Münchberg; Petra Rösch; Michael Bauer; Jürgen Popp
Journal:  Anal Bioanal Chem       Date:  2014-03-21       Impact factor: 4.142

4.  A live bacteria SERS platform for the in situ monitoring of nitric oxide release from a single MRSA.

Authors:  Zhijun Zhang; Xuemei Han; Zhimin Wang; Zhe Yang; Wenmin Zhang; Juan Li; Huanghao Yang; Xing Yi Ling; Bengang Xing
Journal:  Chem Commun (Camb)       Date:  2018-06-21       Impact factor: 6.222

Review 5.  Drug combinations: a strategy to extend the life of antibiotics in the 21st century.

Authors:  Mike Tyers; Gerard D Wright
Journal:  Nat Rev Microbiol       Date:  2019-01-25       Impact factor: 60.633

Review 6.  Raman activated cell sorting.

Authors:  Yizhi Song; Huabing Yin; Wei E Huang
Journal:  Curr Opin Chem Biol       Date:  2016-04-18       Impact factor: 8.822

7.  Surface-Enhanced Raman Scattering for Label-Free Living Single Cell Analysis.

Authors:  Gamze Kuku; Mine Altunbek; Mustafa Culha
Journal:  Anal Chem       Date:  2017-10-25       Impact factor: 6.986

8.  Rapid detection of an anthrax biomarker by surface-enhanced Raman spectroscopy.

Authors:  Xiaoyu Zhang; Matthew A Young; Olga Lyandres; Richard P Van Duyne
Journal:  J Am Chem Soc       Date:  2005-03-30       Impact factor: 15.419

9.  Raman and SERS microscopy for molecular imaging of live cells.

Authors:  Almar F Palonpon; Jun Ando; Hiroyuki Yamakoshi; Kosuke Dodo; Mikiko Sodeoka; Satoshi Kawata; Katsumasa Fujita
Journal:  Nat Protoc       Date:  2013-03-07       Impact factor: 13.491

10.  Using binary surfactant mixtures to simultaneously improve the dimensional tunability and monodispersity in the seeded growth of gold nanorods.

Authors:  Xingchen Ye; Chen Zheng; Jun Chen; Yuzhi Gao; Christopher B Murray
Journal:  Nano Lett       Date:  2013-01-10       Impact factor: 11.189

View more
  4 in total

1.  Rapid, Label-Free Prediction of Antibiotic Resistance in Salmonella typhimurium by Surface-Enhanced Raman Spectroscopy.

Authors:  Ping Zhang; Xi-Hao Wu; Lan Su; Hui-Qin Wang; Tai-Feng Lin; Ya-Ping Fang; Hui-Min Zhao; Wen-Jing Lu; Meng-Jia Liu; Wen-Bo Liu; Da-Wei Zheng
Journal:  Int J Mol Sci       Date:  2022-01-25       Impact factor: 5.923

Review 2.  Prospects of Surface-Enhanced Raman Spectroscopy for Biomarker Monitoring toward Precision Medicine.

Authors:  Javier Plou; Pablo S Valera; Isabel García; Carlos D L de Albuquerque; Arkaitz Carracedo; Luis M Liz-Marzán
Journal:  ACS Photonics       Date:  2022-02-02       Impact factor: 7.529

3.  Fabrication of Ag@Au (core@shell) nanorods as a SERS substrate by the oblique angle deposition process and sputtering technology.

Authors:  Pengxing Sha; Qingqing Su; Peitao Dong; Tianran Wang; Chushu Zhu; Weiye Gao; Xuezhong Wu
Journal:  RSC Adv       Date:  2021-08-09       Impact factor: 4.036

Review 4.  Nanobiotechnology enabled approaches for wastewater based epidemiology.

Authors:  Asifur Rahman; Seju Kang; Wei Wang; Aditya Garg; Ayella Maile-Moskowitz; Peter J Vikesland
Journal:  Trends Analyt Chem       Date:  2021-07-28       Impact factor: 14.908

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.