Literature DB >> 32914419

Implantation of leadless pacing systems in patients early after tricuspid valve surgery: A feasible option.

Cathrin Theis1, Carola Huber1, Philipp Kaesemann1, Bastian Kaiser1, Hannah Heinrich1, Marc Albert2, Ragi Nagib2, Ulrich F W Franke2, Raffi Bekeredjian1.   

Abstract

BACKGROUND: After tricuspid valve (TV) surgery due to tricuspid regurgitation (TR), patients needing a permanent pacemaker often receive an epicardial lead implantation. This may result in delayed recovery from open-chest surgery and increased postoperative risk. Leadless pacemaker (LPM) implantation may represent a valuable option. METHODS AND
RESULTS: A total of 14 consecutive patients underwent LPM implantation (Micra Transcatheter Pacing System, Medtronic, Minneapolis, MN) early after TV surgery. The pacing indication in those patients was atrial fibrillation with a slow atrio-ventricular (AV) conduction or atrial fibrillation and a concomitant AV block III. Three patients already had a pacemaker prior to surgery, which was explanted during TV repair. Three patients received a valve replacement with a bioprosthesis, while the remaining eight patients received a TV repair. All procedural data and device measurements during and after LPM implantation were recorded. Transthoracic echocardiography was performed prior and post LPM implantation, showing no changes in TV or bioprosthesis performance. The device measurements were within an adequate range: threshold: 0.83 ± 0.34 V @ 0.24 ± 0 ms, impedance: 480 ± 58.88 ohm, and R-wave: 10.10 ± 3.60 mV. LPM implantation was successful in all patients with a mean procedural time of 32 ± 11.8 minutes, fluoroscopy time of 3.71 ± 3.15 minutes, and dose-area product of 536.67 ± 811.26 cGy/m2 .
CONCLUSIONS: Implantation of an LPM early after TV surgery is a feasible option. LPM implantation does not affect TV or bioprosthesis performance in transthoracic echocardiography.
© 2020 Wiley Periodicals LLC.

Entities:  

Keywords:  leadless pacemaker implantation; tricuspid surgery

Year:  2020        PMID: 32914419     DOI: 10.1111/pace.14069

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  2 in total

1.  First-in-human combined transcatheter tricuspid valve implantation with leadless VDD pacemaker via left internal jugular approach.

Authors:  Benjamin W Hale; David J Bradley; Jeffrey D Zampi; Wendy Whiteside; Ryan Cunnane
Journal:  HeartRhythm Case Rep       Date:  2021-11-26

Review 2.  Evolution of tricuspid valve regurgitation after implantation of a leadless pacemaker: A single center experience, systematic review, and meta-analysis.

Authors:  Andreas Haeberlin; Joanna Bartkowiak; Nicolas Brugger; Hildegard Tanner; Elaine Wan; Samuel H Baldinger; Jens Seiler; Antonio Madaffari; Gregor Thalmann; Helge Servatius; Laurent Roten; Fabian Noti; Tobias Reichlin
Journal:  J Cardiovasc Electrophysiol       Date:  2022-06-07       Impact factor: 2.942

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.