| Literature DB >> 32913233 |
Takashi Ono1, Yuki Kawasaki1, Lily Wei Chen1, Tetsuya Toyono1, Rika Shirakawa1, Junko Yoshida1, Makoto Aihara1, Takashi Miyai2.
Abstract
The aim of this observational study was to examine the characteristics of anterior and posterior corneal topography in keratoconic eyes more than 30 years after penetrating keratoplasty (PK). Patients who maintained clear grafts for more than 30 years after PK were included and divided into the keratoconus (KC) group or other diseases (Others) group, based on the primary indication. Twenty-six eyes of 26 patients were included. The KC group and the Others group included 14 eyes and 12 eyes, respectively. The KC group participants were younger at the time of surgery (P = 0.03). No differences were found in best-spectacle-corrected visual acuity, keratometric power, and central-corneal-thickness. Based on corneal topography using Fourier harmonic analyses, regular astigmatism in the anterior cornea was significantly larger (P = 0.047) and the spherical component in the posterior cornea was significantly lower (P = 0.01) in the KC group. The area under the receiver operating characteristic curve of the spherical component, regular astigmatism, asymmetry component, and higher-order irregularity were 66.07%, 63.10%, 57.14%, and 59.23%, respectively, in the anterior cornea and 80.65%, 52.98%, 63.10%, and 63.99%, respectively, in the posterior cornea. Our results suggested that Fourier harmonic analysis of corneal topography could be useful for patients with KC long after PK.Entities:
Mesh:
Year: 2020 PMID: 32913233 PMCID: PMC7483710 DOI: 10.1038/s41598-020-71818-w
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Demographic data of patients who maintained clear grafts for more than 30 years after undergoing penetrating keratoplasty.
| All patients | KC group | Others group | ||
|---|---|---|---|---|
| N | 26 | 12 | 14 | |
| Sex (men:women) | 16:10 | 10: 2 | 6: 8 | 0.05 |
| Age at the operation (years) | 30.08 ± 11.94 | 24.67 ± 6.96 | 34.71 ± 12.90 | 0.03* |
| Postoperative term (years) | 37.06 ± 5.81 | 35.13 ± 4.93 | 38.72 ± 5.79 | 0.12 |
| Age at the analysis (years) | 67.13 ± 13.92 | 59.79 ± 6.56 | 73.41 ± 14.96 | 0.01* |
| Best-spectacle-corrected visual acuity (logMAR) | 0.28 ± 0.32 | 0.17 ± 0.32 | 0.37 ± 0.28 | 0.11 |
| Intraocular pressure (mmHg) | 12.80 ± 3.39 | 12.88 ± 3.28 | 12.74 ± 3.36 | 0.92 |
| Central corneal thickness (µm) | 564.65 ± 64.64 | 540.75 ± 49.18 | 585.14 ± 66.68 | 0.07 |
| Thinnest corneal thickness (µm) | 500.88 ± 95.50 | 479.67 ± 96.04 | 519.07 ± 87.54 | 0.30 |
| Corneal endothelial cell density (cells/mm2) | 881.40 ± 419.84 | 999.71 ± 437.37 | 777.88 ± 343.69 | 0.33 |
| Kmax (D) | 52.53 ± 7.32 | 55.28 ± 7.20 | 50.17 ± 6.25 | 0.08 |
| AvgK (D) | 46.70 ± 5.53 | 48.81 ± 5.09 | 44.90 ± 5.04 | 0.07 |
| Incidence of corneal neovascularization (%) | 42.31 | 58.33 | 28.57 | 0.23 |
All data are expressed as the mean ± the standard deviation.
KC, keratoconus; Others, other corneal diseases; logMAR, logarithm of the minimum angle of resolution; Kmax, maximum keratometric power; AvgK, average keratometric corneal power.
*P < 0.05, based on the unpaired t test.
Comparison of corneal topography, using Fourier harmonic analysis, between the KC group and Others group.
| All patients | KC group | Others group | ||
|---|---|---|---|---|
| Spherical component (D) | 51.59 ± 5.30 | 53.41 ± 4.14 | 50.03 ± 5.49 | 0.11 |
| Regular astigmatism (D) | 2.87 ± 2.23 | 3.66 ± 2.82 | 2.19 ± 1.05 | 0.09 |
| Asymmetry component (D) | 2.03 ± 1.68 | 2.02 ± 1.55 | 2.04 ± 1.73 | 0.98 |
| Higher order irregularity (D) | 0.82 ± 0.58 | 0.92 ± 0.56 | 0.74 ± 0.55 | 0.45 |
| Spherical component (D) | 51.65 ± 5.71 | 53.65 ± 4.63 | 49.94 ± 5.80 | 0.10 |
| Regular astigmatism (D) | 2.75 ± 1.94 | 3.55 ± 2.38 | 2.06 ± 0.90 | 0.047* |
| Asymmetry component (D) | 2.88 ± 2.16 | 3.04 ± 2.10 | 2.75 ± 2.13 | 0.74 |
| Higher order irregularity (D) | 0.99 ± 0.64 | 1.10 ± 0.67 | 0.90 ± 0.56 | 0.44 |
| Spherical component (D) | − 5.91 ± 2.64 | − 5.56 ± 3.73 | − 6.21 ± 0.53 | 0.54 |
| Regular astigmatism (D) | 0.54 ± 0.33 | 0.59 ± 0.38 | 0.51 ± 0.27 | 0.55 |
| Asymmetry component (D) | 0.48 ± 0.38 | 0.36 ± 0.26 | 0.59 ± 0.42 | 0.13 |
| Higher order irregularity (D) | 0.19 ± 0.10 | 0.16 ± 0.08 | 0.21 ± 0.10 | 0.28 |
| Spherical component (D) | − 6.36 ± 0.68 | − 6.7 ± 0.37 | − 6.1 ± 0.73 | 0.01* |
| Regular astigmatism (D) | 0.50 ± 0.29 | 0.54 ± 0.31 | 0.47 ± 0.25 | 0.59 |
| Asymmetry component (D) | 0.61 ± 0.41 | 0.48 ± 0.27 | 0.71 ± 0.46 | 0.15 |
| Higher order irregularity (D) | 0.22 ± 0.10 | 0.19 ± 0.08 | 0.24 ± 0.11 | 0.18 |
All data are expressed as the mean ± the standard deviation.
KC, keratoconus; Others, other corneal diseases.
*P < 0.05, based on the unpaired t test.
Comparison of the 1-year changes in characteristics between the KC group and the Others group.
| KC group | Others group | Intergroup | Intergroup | |||||
|---|---|---|---|---|---|---|---|---|
| Value after 1 year | One-year change | Intragroup | Value after 1 year | One-year change | Intragroup | |||
| Best-spectacle-corrected visual acuity (logMAR) | 0.34 ± 0.54 | 0.16 ± 0.37 | 0.20 | 0.43 ± 0.28 | 0.06 ± 0.31 | 0.50 | 0.63 | 0.49 |
| Intraocular pressure (mmHg) | 13.18 ± 3.27 | 0.67 ± 2.58 | 0.43 | 13.36 ± 3.65 | 0.63 ± 3.3 | 0.50 | 0.90 | 0.97 |
| Central corneal thickness (µm) | 536.73 ± 53.12 | − 8.27 ± 21.21 | 0.25 | 571.93 ± 66.34 | − 13.21 ± 25.38 | 0.08 | 0.18 | 0.62 |
| Thinnest corneal thickness (µm) | 483.73 ± 95.35 | 1.00 ± 30.60 | 0.92 | 501.14 ± 95.36 | − 17.93 ± 39.00 | 0.12 | 0.67 | 0.22 |
| Corneal endothelial cell density (cells/mm2) | 777.33 ± 188.64 | − 145.83 ± 239.35 | 0.27 | 840.78 ± 194.10 | 32.50 ± 242.05 | 0.78 | 0.27 | 0.27 |
| Kmax (D) | 58.18 ± 8.62 | 2.98 ± 4.31 | 0.05 | 50.97 ± 6.55 | 0.80 ± 1.91 | 0.16 | 0.03* | 0.12 |
| AvgK (D) | 48.80 ± 5.40 | − 0.17 ± 0.69 | 0.44 | 45.10 ± 5.13 | 0.20 ± 0.66 | 0.29 | 0.11 | 0.20 |
All data are expressed as the mean ± the standard deviation.
KC, keratoconus; Others, other corneal diseases; logMAR, logarithm of the minimum angle of resolution; Kmax, maximum keratometric power; AvgK, average keratometric corneal power.
*P < 0.05, unpaired t test.
Comparison of the 1-year changes in corneal topography, using Fourier harmonic analysis, between the KC group and the Others group.
| KC group | Others group | Intergroup | Intergroup | |||||
|---|---|---|---|---|---|---|---|---|
| Value after 1 year | One-year change | Intragroup | Value after 1 year | One-year change | Intragroup | |||
| Spherical component (D) | 53.50 ± 5.39 | 0.12 ± 1.76 | 0.83 | 50.59 ± 5.42 | 0.56 ± 0.95 | 0.05 | 0.21 | 0.45 |
| Regular astigmatism (D) | 3.85 ± 2.99 | − 0.11 ± 1.18 | 0.78 | 2.46 ± 1.09 | 0.27 ± 0.92 | 0.31 | 0.14 | 0.39 |
| Asymmetry component (D) | 1.30 ± 0.63 | − 0.74 ± 1.46 | 0.14 | 1.73 ± 1.70 | − 0.31 ± 0.95 | 0.26 | 0.45 | 0.40 |
| Higher order irregularity (D) | 0.93 ± 0.68 | − 0.03 ± 0.33 | 0.81 | 0.71 ± 0.63 | − 0.03 ± 0.28 | 0.72 | 0.44 | 0.98 |
| Spherical component (D) | 53.93 ± 6.15 | 0.31 ± 1.76 | 0.59 | 50.01 ± 5.81 | 0.06 ± 0.82 | 0.78 | 0.13 | 0.66 |
| Regular astigmatism (D) | 3.75 ± 2.56 | − 0.05 ± 1.16 | 0.89 | 2.16 ± 0.91 | 0.11 ± 0.69 | 0.59 | 0.05 | 0.69 |
| Asymmetry component (D) | 2.77 ± 1.82 | − 0.28 ± 0.66 | 0.20 | 2.66 ± 2.12 | − 0.09 ± 0.75 | 0.68 | 0.89 | 0.52 |
| Higher order irregularity (D) | 1.27 ± 0.97 | 0.12 ± 0.46 | 0.43 | 0.97 ± 0.70 | 0.07 ± 0.27 | 0.35 | 0.40 | 0.76 |
| Spherical component (D) | − 6.72 ± 0.40 | − 0.04 ± 0.08 | 0.14 | − 5.96 ± 1.69 | 0.25 ± 1.35 | 0.51 | 0.17 | 0.50 |
| Regular astigmatism (D) | 0.61 ± 0.40 | − 0.01 ± 0.17 | 0.80 | 0.51 ± 0.28 | 0.00 ± 0.22 | 0.99 | 0.50 | 0.87 |
| Asymmetry component (D) | 0.29 ± 0.20 | − 0.01 ± 0.06 | 0.57 | 0.49 ± 0.33 | − 0.10 ± 0.33 | 0.32 | 0.11 | 0.44 |
| Higher order irregularity (D) | 0.20 ± 0.16 | 0.04 ± 0.09 | 0.26 | 0.24 ± 0.13 | 0.04 ± 0.11 | 0.29 | 0.57 | 0.99 |
| Spherical component (D) | − 6.72 ± 0.38 | − 0.03 ± 0.06 | 0.21 | − 6.18 ± 0.67 | − 0.12 ± 0.21 | 0.06 | 0.03* | 0.18 |
| Regular astigmatism (D) | 0.55 ± 0.35 | − 0.01 ± 0.15 | 0.79 | 0.48 ± 0.24 | 0.01 ± 0.17 | 0.88 | 0.56 | 0.77 |
| Asymmetry component (D) | 0.40 ± 0.20 | − 0.04 ± 0.11 | 0.22 | 0.62 ± 0.36 | − 0.09 ± 0.31 | 0.31 | 0.10 | 0.66 |
| Higher order irregularity (D) | 0.23 ± 0.17 | 0.03 ± 0.10 | 0.33 | 0.26 ± 0.14 | 0.02 ± 0.09 | 0.40 | 0.56 | 0.81 |
All data are expressed as the mean ± the standard deviation.
KC, keratoconus; Others, other corneal diseases.
*P < 0.05, based on the unpaired t test.
Figure 1The receiver operating characteristic (ROC) curves of the four components, using Fourier harmonic analysis. (a) The ROC curves of the four components of the anterior cornea in the examination with the 6-mm diameter. The areas under the curve (AUCs) of the spherical component, regular astigmatism, asymmetry component, and higher order irregularity are 66.07% (95% confidence interval, 44.38–87.76%), 63.10% (95% confidence interval, 39.08–87.11%), 57.14% (95% confidence interval, 33.59–80.69%), and 59.23% (95% confidence interval, 36.03–82.42%), respectively. (b) The ROC curves of the four components, using Fourier harmonic analysis, of the posterior cornea in the examination with the 6-mm diameter. The AUCs of the spherical component, regular astigmatism, asymmetry component, and higher order irregularity are 80.65% (95% confidence interval, 62.59–98.72%), 52.98% (95% confidence interval, 28.92–77.03%), 63.10% (95% confidence interval, 40.80–85.39%), and 63.99% (95% confidence interval, 41.91–86.06%), respectively.