| Literature DB >> 32909834 |
Zhe Wang1.
Abstract
OBJECTIVE: To identify the environmental factors essential for infection control in senior-living facilities.Entities:
Keywords: environmental design; infection control; long-term care facilities; older adults; senior living
Mesh:
Year: 2020 PMID: 32909834 PMCID: PMC7484597 DOI: 10.1177/1937586720953519
Source DB: PubMed Journal: HERD ISSN: 1937-5867
Participant Facilities During the Lockdown.
| Facility | Year Built | Capacity | Existing Residents | COVID-19 Patients | In-House Healthcare Personnel | Guideline Use | Single Rooms for Patients | Single Rooms for Staff | Dedicated AC Systems | Dedicated Patient Areas | Dedicated Circulation Systems |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2006 | 250 | 163 | 5 | 3 | Yes | Yes | No | No AC | Yes | No |
| 2 | 2009 | 360 | 272 | 8 | 8 | Yes | Yes | No | Yes | No | No |
| 3 | 1998 | 120 | 101 | 3 | 2 | Yes | Yes | No | No | Yes | No |
| 4 | 2013 | 100 | 89 | 3 | 2 | Yes | Yes | No | No | Yes | No |
| 5 | 2015 | 120 | 90 | 3 | 1 | Yes | Yes | No | No AC | Yes | No |
| 6 | 2006 | 150 | 131 | 2 | 1 | Yes | Yes | No | No | Yes | No |
Note. AC = air-conditioning.
Essential Environmental Factors for COVID-19 Control in Senior-Living Facilities.
| Factors | Keep COVID-19 From Entering the Facility | Prevent COVID-19 Spread in the Facility | Manage Infection and Illness |
|---|---|---|---|
| Site-level | Loading zones/areas for material handover | Environmental zones (contaminated, semi-clean, and clean) for necessary separation | Built-in medical station |
| Dedicated parking areas for visiting vehicles | Dedicated areas for staff’s facility stay | Access to telemedicine | |
| Signage systems for infection-control management | Dedicated areas for facility kitchen | Outdoor environments for physical activities | |
| Building-level | Reception room for visitor screening and registration | Natural ventilation | |
| Storage for devices needed for screening | Dedicated patient areas | ||
| Storage for disinfection supplies | Dedicated air-conditioning systems | ||
| Signage systems for infection-control management | Dedicated circulation systems | ||
| Storage for disinfection supplies and equipment | Designated space for household waste in patient areas | ||
| Room-level | Signage systems for infection-control management | Backup mechanical ventilation at the room level | |
| Access to telemedicine, internet, television, radio, reading materials, and items for cultural and entertainment services | |||
| Storage for devices used in daily inspection | |||
| Dining room furnishing for social distancing | Relatively independent single rooms for patients | ||