A comparison of the marginal fit of three cast ceramic crown systems.

P Schaerer1, T Sato, A Wohlwend.   

Abstract

The conclusions were: 1. The Cerestore crown system produced an impressive marginal fit without technique sensitivity. However, irregularities on the crown margin due to the porosities of the fired core were noted. 2. The Dicor castable ceramic crown system in this study produced rounded marginal openings because of the shrinkage during ceramming, the treatment of the surface texture after ceramming, and damage from air abrasives. 3. The Ceplatec crown system produced a suitable marginal fit when the distortion of the foil coping during porcelain firing was controlled. The quality of the margin was ultimately determined by the skill of the technician.

Mesh:

Substances:

Year:  1988        PMID: 3290447     DOI: 10.1016/0022-3913(88)90065-0

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

1.  Precision of fit: zirconia three-unit fixed dental prostheses.

Authors:  Florian Beuer; Michael Naumann; Wolfgang Gernet; John A Sorensen
Journal:  Clin Oral Investig       Date:  2008-09-04       Impact factor: 3.573

2.  Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials.

Authors:  Joana Schönberger; Kurt-Jürgen Erdelt; Daniel Bäumer; Florian Beuer
Journal:  Clin Oral Investig       Date:  2017-02-04       Impact factor: 3.573

3.  Dental Wings CAD/CAM system precision: an internal and marginal fit sperimental analisys.

Authors:  G Sannino; F Gloria; R Schiavetti; L Ottria; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2010-04-20

4.  Evaluation of fracture strength for single crowns made of the different types of lithium disilicate glass-ceramics.

Authors:  Chung-Ha Lim; Yong-Seok Jang; Min-Ho Lee; Tae-Sung Bae
Journal:  Odontology       Date:  2019-09-28       Impact factor: 2.634

5.  Marginal and internal fit of zirconia based fixed dental prostheses fabricated with different concepts.

Authors:  Florian Beuer; Natalie Korczynski; Antonia Rezac; Michael Naumann; Wolfgang Gernet; John A Sorensen
Journal:  Clin Cosmet Investig Dent       Date:  2010-02-25

6.  Gap comparison between single crown and three-unit bridge zirconia substructures.

Authors:  Chuchai Anunmana; Masnisa Charoenchitt; Chanavut Asvanund
Journal:  J Adv Prosthodont       Date:  2014-08-14       Impact factor: 1.904

  6 in total