Literature DB >> 32904196

Outcomes with Two Tapered Wedge Femoral Stems in Total Hip Arthroplasty Using an Anterior Approach.

Jonathan A Gabor1, Vivek Singh1, Jorge A Padilla2, Ran Schwarzkopf1, Roy I Davidovitch1.   

Abstract

BACKGROUND: The majority of hip arthroplasties in the United States utilize cementless acetabular and femoral components. Despite their similarities, stem geometry can still differ. The purpose of this study is to compare the clinical results of two wedge-type stem designs.
METHODS: A retrospective study of patients who underwent primary THA utilizing a direct anterior approach between January 2016 and January 2017. Two cohorts were established based on femoral stem design implanted. Descriptive patient characteristics and surgical and clinical data was extracted which included surgical time, length of stay (LOS), presence of pain (categorized as groin, hip, or thigh pain) at the latest follow-up, and revisions. Immediate postoperative radiographs were compared with the latest follow-up radiographs to assess limb length discrepancies, stem alignment, and stem subsidence.
RESULTS: A total of 544 patients were included. 297 patients received the Group A stem (morphometric) and 247 patients received the Group B stem (flat-tapered). A significantly higher proportion of Group B stems subsided ≥3 mm and were in varus alignment than the Group A design. Additionally, a significantly greater number of patients who received the Group B stem reported postoperative hip and thigh pain. The logistic regression found that the Group B stem was 2.32 times more likely to subside ≥3 mm than the Group A stem.
CONCLUSION: Our study suggests modestly improved radiographic and clinical outcomes and fewer instances of thigh pain, subsidence, and varus alignment in the patients who received the Group Ahip stem. Further studies are warranted to assess long-term significance.

Entities:  

Keywords:  Direct anterior approach; Flat-tapered stem; Morphometric femoral stem; Total hip arthroplasty

Year:  2020        PMID: 32904196      PMCID: PMC7452259          DOI: 10.1016/j.jor.2020.08.010

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  27 in total

1.  Results of a tapered cementless femoral stem implanted in varus.

Authors:  Cyna Khalily; D Kevin Lester
Journal:  J Arthroplasty       Date:  2002-06       Impact factor: 4.757

2.  The Effect of Price on Surgeons' Choice of Implants: A Randomized Controlled Survey.

Authors:  Amy S Wasterlain; Eitan Melamed; Ricardo Bello; Raj Karia; John T Capo
Journal:  J Hand Surg Am       Date:  2017-06-10       Impact factor: 2.230

3.  Surgeon's Preference in Total Knee Replacement: A Quantitative Examination of Attributes, Reasons for Alteration, and Barriers to Change.

Authors:  Christopher J Vertullo; Peter M Grimbeek; Stephen E Graves; Peter L Lewis
Journal:  J Arthroplasty       Date:  2017-04-27       Impact factor: 4.757

4.  Is there any difference between tapered titanium stems with similar geometry and hydroxyapatite coating?

Authors:  G Cinotti; G Mazzotta; F Romana Ripani; G La Torre; G Giannicola
Journal:  Musculoskelet Surg       Date:  2019-01-08

5.  Structural and cellular assessment of bone quality of proximal femur.

Authors:  L D Dorr; M C Faugere; A M Mackel; T A Gruen; B Bognar; H H Malluche
Journal:  Bone       Date:  1993 May-Jun       Impact factor: 4.398

6.  Distal fixation of proximally coated tapered stems may predispose to a failure of osteointegration.

Authors:  H John Cooper; Anitha P Jacob; José A Rodriguez
Journal:  J Arthroplasty       Date:  2011-05-23       Impact factor: 4.757

7.  Patients' perception of pain after total hip arthroplasty.

Authors:  R L Barrack; W Paprosky; R A Butler; A Palafox; E Szuszczewicz; L Myers
Journal:  J Arthroplasty       Date:  2000-08       Impact factor: 4.757

8.  Influence of cementless femoral stems inserted in varus on functional outcome in primary total hip arthroplasty.

Authors:  Justin de Beer; Scott McKenzie; Matthias Hubmann; Danielle Petruccelli; Mitchell Winemaker
Journal:  Can J Surg       Date:  2006-12       Impact factor: 2.089

9.  Total Hip Intraoperative Femur Fracture: Do the Design Enhancements of a Second-Generation Tapered-Wedge Stem Reduce the Incidence?

Authors:  Nicholas D Colacchio; Claire E Robbins; Mehran S Aghazadeh; Carl T Talmo; James V Bono
Journal:  J Arthroplasty       Date:  2017-05-15       Impact factor: 4.757

10.  Hydroxyapatite coating does not improve uncemented stem survival after total hip arthroplasty!

Authors:  Nils P Hailer; Stergios Lazarinis; Keijo T Mäkelä; Antti Eskelinen; Anne M Fenstad; Geir Hallan; Leif Havelin; Søren Overgaard; Alma B Pedersen; Frank Mehnert; Johan Kärrholm
Journal:  Acta Orthop       Date:  2014-09-01       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.