| Literature DB >> 32904158 |
Chun-Hao Chang1, Yi-Ju Hsu1, Fang Li1, Yu-Tsai Tu1,2, Wei-Lun Jhang1, Chih-Wen Hsu1, Chi-Chang Huang1, Chin-Shan Ho1.
Abstract
BACKGROUND: Inertial sensors, such as accelerometers, serve as convenient devices to predict the energy expenditures (EEs) during physical activities by a predictive equation. Although the accuracy of estimate EEs especially matter to athletes receive physical training, most EE predictive equations adopted in accelerometers are based on the general population, not athletes. This study included the heart rate reserve (HRR) as a compensatory parameter for physical intensity and derived new equations customized for sedentary, regularly exercising, non-endurance athlete, and endurance athlete adults.Entities:
Keywords: Athlete; Energy expenditure; Heart rate reserve; Oxygen uptake; Physical fitness; Wearable sensor
Year: 2020 PMID: 32904158 PMCID: PMC7450994 DOI: 10.7717/peerj.9717
Source DB: PubMed Journal: PeerJ ISSN: 2167-8359 Impact factor: 2.984
Anthropometry and body composition characteristics of participants.
| SG | EHG | NEG | EG | Range | ||
|---|---|---|---|---|---|---|
| Age (years) | 21.9 ± 1.9 | 21.7 ± 1.6 | 21.1 ± 1.7 | 20.9 ± 1.7 | 0.118 | 18.0–26.0 |
| Height (cm) | 166.9 ± 8.1 | 167.3 ± 8.5 | 171.2 ± 7.7 | 170.0 ± 5.8 | 0.078 | 150.0–182.0 |
| Sex | 12 males 18 females | 14 males 16 females | 17 males 13 females | 19 males 11 females | ||
| Body mass (kg) | 67.2 ± 13.9 | 64.6 ± 12.6 | 68.7 ± 16.9 | 59.8 ± 8.0 | 0.057 | 46.0–133.6 |
| BMI (kg/m2) | 23.7 ± 3.5 | 23.1 ± 3.3 | 23.3 ± 4.7 | 20.8 ± 2.1 | 0.010 | 17.0–38.1 |
| Skeletal muscle mass (kg) | 26.6 ± 5.7 | 28.4 ± 6.0 | 32.1 ± 7.1 | 29.1 ± 4.5 | 0.005 | 18.0–51.4 |
| Percentage of body fat (%) | 19.1 ± 8.5 | 20.2 ± 6.6 | 16.3 ± 5.4 | 8.4 ± 3.8 | <0.001 | 2.7–35.8 |
| RMR (kcal/day) | 1414.1 ± 200.7 | 1464.2 ± 206.9 | 1591.1 ± 250.6 | 1490.0 ± 160.0 | 0.011 | 1102.0–2295.0 |
Notes.
Significantly different from NEG, p < 0.05.
Significantly different from EG, p < 0.05.
Values are reported as the mean ± standard deviation.
sedentary group
exercise habit group
non- endurance group
endurance group
body mass index
resting metabolic rate
p-value was calculated from one-way ANOVA test among the four groups
Figure 1(A) CMEE and (B) GT9X EE during treadmill walking/running tests at different speeds.
CMEE, criterion measure of energy expenditure measured by the indirect calorimetry (Vmax system). GT9X EE, energy expenditure predicted by the accelerometer (ActiGraph GT9X-Link). * Significantly different from NEG, p < 0.05. † Significantly different from EG, p < 0.05.
Comparison of EE measured by indirect calorimetry (Vmax system) and EE estimated by GT9X EE, and HR in five treadmill walking/running tests.
| Group | Treadmill speed (km/h) | CMEE (kcal kg−1 min−1) | GT9X EE (kcal kg−1 min−1) | ES | MAPE (%) | ICC | HRrest(BPM) | HRmax (BPM) |
|---|---|---|---|---|---|---|---|---|
| SG | 4.80 | 0.069 ± 0.007 | 0.065 ± 0.008 | 0.53 | 4.3 | 0.851 | 81.34 ± 8.97 | 108.59 ± 13.60 |
| 6.42 | 0.106 ± 0.012 | 0.103 ± 0.017 | 0.20 | 131.29 ± 14.24 | ||||
| 8.04 | 0.144 ± 0.007 | 0.139 ± 0.033 | 0.21 | 157.06 ± 11.01 | ||||
| 9.66 | 0.169 ± 0.011 | 0.164 ± 0.024 | 0.27 | 172.71 ± 12.17 | ||||
| 11.28 | 0.194 ± 0.012 | 0.182 ± 0.023 | 0.65 | 183.37 ± 13.64 | ||||
| EHG | 4.80 | 0.068 ± 0.005 | 0.067 ± 0.009 | 0.14 | 3.0 | 0.915 | 75.96 ± 7.02 | 101.26 ± 8.88 |
| 6.42 | 0.111 ± 0.010 | 0.109 ± 0.019 | 0.13 | 124.14 ± 11.19 | ||||
| 8.04 | 0.147 ± 0.011 | 0.145 ± 0.020 | 0.12 | 146.11 ± 12.96 | ||||
| 9.66 | 0.168 ± 0.011 | 0.165 ± 0.020 | 0.19 | 163.12 ± 12.06 | ||||
| 11.28 | 0.201 ± 0.014 | 0.183 ± 0.022 | 0.98 | 176.39 ± 11.97 | ||||
| NEG | 4.80 | 0.073 ± 0.013 | 0.065 ± 0.014 | 0.59 | 15.7 | 0.778 | 76.81 ± 8.03 | 98.53 ± 11.46 |
| 6.42 | 0.125 ± 0.012 | 0.102 ± 0.024 | 1.21 | 120.08 ± 10.79 | ||||
| 8.04 | 0.160 ± 0.014 | 0.137 ± 0.025 | 1.14 | 138.99 ± 11.51 | ||||
| 9.66 | 0.188 ± 0.018 | 0.159 ± 0.024 | 1.37 | 153.81 ± 12.97 | ||||
| 11.28 | 0.217 ± 0.020 | 0.180 ± 0.019 | 1.90 | 169.62 ± 12.24 | ||||
| EG | 4.80 | 0.073 ± 0.013 | 0.067 ± 0.013 | 0.46 | 11.2 | 0.837 | 66.93 ± 9.20 | 86.81 ± 12.94 |
| 6.42 | 0.117 ± 0.016 | 0.101 ± 0.027 | 0.72 | 104.36 ± 14.35 | ||||
| 8.04 | 0.154 ± 0.010 | 0.140 ± 0.023 | 0.79 | 122.82 ± 15.89 | ||||
| 9.66 | 0.180 ± 0.010 | 0.162 ± 0.026 | 0.91 | 134.41 ± 17.45 | ||||
| 11.28 | 0.210 ± 0.014 | 0.178 ± 0.015 | 2.21 | 145.36 ± 18.07 |
Notes.
Significantly different from CMEE, p < 0.05.
Values are reported as the mean ± standard deviation.
sedentary group
exercise habit group
non-endurance group
endurance group
criterion measure energy expenditure
ActiGraph GT9X-Link accelerometer
Effect size (Cohen’s d); Mean absolute percentage error (MAPE) = [(predicted value - actual value)/actual value] * 100/n
intraclass correlation coefficient
the pre-test measure of resting HR
the highest HR measured for each phase of the test
beats per minutes
Modified models to predict EE (kcal kg−1 min−1) from VM, BW, and HRR.
| Group | Coefficients | Unstandardized coefficients (B) | Standardized coefficients ( | VIF | SEE | D-W test | |||
|---|---|---|---|---|---|---|---|---|---|
| SG | Constant | 0.039438 | <0.001 | 0.851 | 0.018 | 278.39 | 1.827 | ||
| VM | 0.000004 | 0.255 | <0.001 | 2.995 | |||||
| BM | −0.000117 | −0.035 | <0.001 | 1.004 | |||||
| HRR | 0.001077 | 0.701 | 0.279 | 2.990 | |||||
| EHG | Constant | 0.037952 | <0.001 | 0.869 | 0.018 | 321.95 | 2.046 | ||
| VM | 0.000007 | 0.396 | 0.072 | 3.309 | |||||
| BM | −0.000219 | −0.057 | <0.001 | 1.096 | |||||
| HRR | 0.000954 | 0.578 | <0.001 | 3.292 | |||||
| NEG | Constant | 0.066446 | <0.001 | 0.863 | 0.020 | 306.49 | 1.309 | ||
| VM | 0.000007 | 0.343 | <0.001 | 2.653 | |||||
| BM | −0.000558 | −0.167 | <0.001 | 1.097 | |||||
| HRR | 0.001240 | 0.639 | <0.001 | 2.717 | |||||
| EG | Constant | 0.028271 | 0.026 | 0.864 | 0.019 | 308.59 | 1.245 | ||
| VM | 0.000012 | 0.603 | <0.001 | 2.942 | |||||
| BM | −0.000144 | −0.023 | 0.449 | 1.019 | |||||
| HRR | 0.000771 | 0.371 | <0.001 | 2.940 |
Notes.
Modified models were developed on 70% of samples for modeling and cross-validated on the remaining 30% samples.
vector magnitudes
body mass in kg
heart rate reserve
variance inflation factor
coefficient of determination which was measured from linear regression models
standard error of estimate
test, Durbin-Watson test
Figure 2(A) SG, (B) EHG, (C) NEG, and (D) EG measured EE by Vmax system (CMEE), and estimated EE GT9X EE (Freedson VM3 Combination) and modified models EE by GT9X in treadmill tests.
Validity and reliability analysis of the predicted EE in models and CMEE in different groups.
| Group | Freedson VM3 Combination | Modified models | ||
|---|---|---|---|---|
| ICC | ICC | |||
| SG | 0.858 | 0.851 | 0.922 | 0.919 |
| EHG | 0.925 | 0.915 | 0.932 | 0.930 |
| NEG | 0.875 | 0.778 | 0.929 | 0.927 |
| EG | 0.917 | 0.837 | 0.930 | 0.927 |
Notes.
sedentary group
exercise habit group
non-endurance group
endurance group
Pearsons correlation coefficient
intraclass correlation coefficient