Metamaterial-Inspired Radiofrequency (RF) Shield With Reduced Specific Absorption Rate (SAR) and Improved Transmit Efficiency for UHF MRI.

Haiwei Chen, Lei Guo, Mingyan Li, Aurelien Destruel, Chunyi Liu, Ewald Weber, Feng Liu, Stuart Crozier.   

Abstract

To prevent the interferences between radiofrequency (RF) coils and other components in the magnetic resonance imaging (MRI) system such as gradient coils, it is essential to place an RF shield between the RF coils and gradient coils. However, the induced currents on conventional RF shields have negative influences on the RF coil performance. To reduce these influences, metamaterial absorbers (MA), a class of metamaterials exhibiting nearly unity absorption rate for the incident electromagnetic fields, can be employed for the design of a novel RF shield. However, the adoption of metamaterials in MRI systems is usually problematic because of the bulkiness of the metamaterial structure. In this work, capacitors and metallic interconnectors are used to miniaturize the MA so that the unit MA cell can operate at the Larmor frequencies of 7T and 9.4T MRI and stay compact. This MA-RF shield is used to improve the transmit efficiency of RF surface coils and reduce the specific absorption rate (SAR) in the region of interest (ROI). It is successfully demonstrated by simulations and experiments that, compared with conventional RF shield structure, the transmit efficiency can be enhanced by more than 32% and the peak SAR value can be reduced by 22% using the MA-RF shield. Moreover, it is observed that the transmit field penetration is improved when the surface coil is used with the MA-RF shield. This proof-of-concept study suggests a new practical way for the utilization of metamaterials in ultra-high field MRI applications.

Entities:  

Mesh:

Year:  2021        PMID: 32903175     DOI: 10.1109/TBME.2020.3022884

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  2 in total

1.  A co-polarization-insensitive metamaterial absorber for 5G n78 mobile devices at 3.5 GHz to reduce the specific absorption rate.

Authors:  Saif Hannan; Mohammad Tariqul Islam; Mohamed S Soliman; Mohammad Rashed Iqbal Faruque; Norbahiah Misran; Md Shabiul Islam
Journal:  Sci Rep       Date:  2022-07-01       Impact factor: 4.996

2.  A Preliminary Study for Reference RF Coil at 11.7 T MRI: Based on Electromagnetic Field Simulation of Hybrid-BC RF Coil According to Diameter and Length at 3.0, 7.0 and 11.7 T.

Authors:  Jeung-Hoon Seo; Jun-Young Chung
Journal:  Sensors (Basel)       Date:  2022-02-15       Impact factor: 3.576