Yanjie Tian1, Yinhao Wang1, Ziyuan Liu1, Xuemin Li2. 1. Department of Ophthalmology, Peking University Third Hospital, No. 49, Garden North Road, Haidian District, Beijing, China. 2. Department of Ophthalmology, Peking University Third Hospital, No. 49, Garden North Road, Haidian District, Beijing, China. lxmlxm66@sina.com.
Abstract
PURPOSE: To establish a more sensitive diagnostic tool for traumatic optic neuropathy (TON), we explored the diagnostic efficacy of isolated-check visual evoked potential (ic-VEP) for TON in orbital fracture and compared ic-VEP with pattern-reversal visual evoked potential (P-VEP) testing. METHODS: This was a prospective single-center study. A total of 137 eyes from 131 patients diagnosed between December 2016 and October 2019 with orbital fractures were included in the study. Injury history, best-corrected visual acuity (BCVA), visual field, computed tomography (CT), P-VEP, and ic-VEP data were collected. Parameters of ic-VEP (signal-to-noise ratio [SNR]) and P-VEP (peak latency and amplitude of P100) were compared and diagnostic accuracy was analyzed. RESULTS: TON was associated with worse BCVA than non-TON (median 0.52 versus 0.10 logMAR, P < 0.001). SNRs were negatively associated with the P100 peak latency while positively associated with the P100 amplitude. The sensitivity of ic-VEP for TON (79.6%) was higher than that of P-VEP (61.2%, P = 0.049), although this difference was not statistically significant after Bonferroni correction. Using ic-VEP and P-VEP together could increase sensitivity (87.8%). Maximum areas under curve were obtained using the SNR criteria of 1.3, 1.47, and 1.54 at 8%, 16%, and 32% depth of modulation, respectively. CONCLUSION: ic-VEP was more sensitive than P-VEP in diagnosing TON, and a combination of the two examination tests was recommended. The use of ic-VEP as the new diagnostic standard technique for TON should be considered.
PURPOSE: To establish a more sensitive diagnostic tool for traumatic optic neuropathy (TON), we explored the diagnostic efficacy of isolated-check visual evoked potential (ic-VEP) for TON in orbital fracture and compared ic-VEP with pattern-reversal visual evoked potential (P-VEP) testing. METHODS: This was a prospective single-center study. A total of 137 eyes from 131 patients diagnosed between December 2016 and October 2019 with orbital fractures were included in the study. Injury history, best-corrected visual acuity (BCVA), visual field, computed tomography (CT), P-VEP, and ic-VEP data were collected. Parameters of ic-VEP (signal-to-noise ratio [SNR]) and P-VEP (peak latency and amplitude of P100) were compared and diagnostic accuracy was analyzed. RESULTS: TON was associated with worse BCVA than non-TON (median 0.52 versus 0.10 logMAR, P < 0.001). SNRs were negatively associated with the P100 peak latency while positively associated with the P100 amplitude. The sensitivity of ic-VEP for TON (79.6%) was higher than that of P-VEP (61.2%, P = 0.049), although this difference was not statistically significant after Bonferroni correction. Using ic-VEP and P-VEP together could increase sensitivity (87.8%). Maximum areas under curve were obtained using the SNR criteria of 1.3, 1.47, and 1.54 at 8%, 16%, and 32% depth of modulation, respectively. CONCLUSION: ic-VEP was more sensitive than P-VEP in diagnosing TON, and a combination of the two examination tests was recommended. The use of ic-VEP as the new diagnostic standard technique for TON should be considered.
Authors: Chloe N Thomas; Adam M Thompson; Eleanor McCance; Martin Berry; Ann Logan; Richard J Blanch; Zubair Ahmed Journal: Invest Ophthalmol Vis Sci Date: 2018-09-04 Impact factor: 4.799
Authors: Peter F Svider; Michael Bobian; Houmehr Hojjat; Anthony Sheyn; Giancarlo Zuliani; Jean Anderson Eloy; Adam J Folbe Journal: Int J Pediatr Otorhinolaryngol Date: 2016-06-01 Impact factor: 1.675
Authors: Dunya M Atisha; Tucker van Rensselaer Burr; Alexander C Allori; Liana Puscas; Detlev Erdmann; Jeffrey R Marcus Journal: Plast Reconstr Surg Date: 2016-02 Impact factor: 4.730