Separation of fluid and solid shear wave fields and quantification of coupling density by magnetic resonance poroelastography.

Ledia Lilaj1, Thomas Fischer2, Jing Guo1, Jürgen Braun3, Ingolf Sack1, Sebastian Hirsch4,5.   

Abstract

PURPOSE: Biological soft tissues often have a porous architecture comprising fluid and solid compartments. Upon displacement through physiological or externally induced motion, the relative motion of these compartments depends on poroelastic parameters, such as coupling density ( ρ 12 ) and tissue porosity. This study introduces inversion recovery MR elastography (IR-MRE) (1) to quantify porosity defined as fluid volume over total volume, (2) to separate externally induced shear strain fields of fluid and solid compartments, and (3) to quantify coupling density assuming a biphasic behavior of in vivo brain tissue. THEORY AND METHODS: Porosity was measured in eight tofu phantoms and gray matter (GM) and white matter (WM) of 21 healthy volunteers. Porosity of tofu was compared to values obtained by fluid draining and microscopy. Solid and fluid shear-strain amplitudes and ρ 12 were estimated both in phantoms and in in vivo brain.
RESULTS: T1 -based measurement of tofu porosity agreed well with reference values (R = 0.99, P < .01). Brain tissue porosity was 0.14 ± 0.02 in GM and 0.05 ± 0.01 in WM (P < .001). Fluid shear strain was found to be phase-locked with solid shear strain but had lower amplitudes in both tofu phantoms and brain tissue (P < .05). In accordance with theory, tofu and brain ρ 12 were negative.
CONCLUSION: IR-MRE allowed for the first time separation of shear strain fields of solid and fluid compartments for measuring coupling density according to the biphasic theory of poroelasticity. Thus, IR-MRE opens horizons for poroelastography-derived imaging markers that can be used in basic research and diagnostic applications.
© 2020 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  brain tissue; coupling density; elastography; inversion recovery; phantom; porosity

Mesh:

Year:  2020        PMID: 32902011     DOI: 10.1002/mrm.28507

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  3 in total

1.  Valsalva Maneuver Decreases Liver and Spleen Stiffness Measured by Time-Harmonic Ultrasound Elastography.

Authors:  Tom Meyer; Heiko Tzschätzsch; Brunhilde Wellge; Ingolf Sack; Thomas Kröncke; Alma Martl
Journal:  Front Bioeng Biotechnol       Date:  2022-05-26

2.  Cerebral Ultrasound Time-Harmonic Elastography Reveals Softening of the Human Brain Due to Dehydration.

Authors:  Bernhard Kreft; Judith Bergs; Mehrgan Shahryari; Leon Alexander Danyel; Stefan Hetzer; Jürgen Braun; Ingolf Sack; Heiko Tzschätzsch
Journal:  Front Physiol       Date:  2021-01-11       Impact factor: 4.566

3.  Multiscale Coupling of One-dimensional Vascular Models and Elastic Tissues.

Authors:  Luca Heltai; Alfonso Caiazzo; Lucas O Müller
Journal:  Ann Biomed Eng       Date:  2021-07-19       Impact factor: 3.934