Literature DB >> 32894703

Validated specific HPLC-DAD method for simultaneous estimation of paracetamol and chlorzoxazone in the presence of five of their degradation products and toxic impurities.

Amira F El-Yazbi1, Karin M Guirguis2, Mona M Bedair1, Tarek S Belal1.   

Abstract

This work demonstrates a specific and reliable HPLC with diode array detection (DAD) method for the simultaneous estimation of paracetamol (PAR) and chlorzoxazone (CZ) in the presence of five of their degradation products and toxic impurities; namely; 4-aminophenol (AP), 4-nitrophenol (NP), acetanilide (AT), 4-chloroacetanilide (CA) and 2-amino-4-chlorophenol (ACP). Successful chromatographic separation was accomplished using Waters Symmetry C8 column (3.9 × 150 mm, 5 μm) with gradient elution of the mobile phase consisting of 0.05 M phosphate buffer pH 7.5 and methanol. The gradient elution started with 5% (by volume) methanol ramped up linearly to 50% in 10 min, and then maintained at this percentage afterward till the end of the run. The mobile phase was pumped at a flow rate of 1.0 mL/min. The multiple wavelength detector was adjusted at 244 and 285 nm to quantify PAR and CZ, respectively. Additionally, the wavelength 270 nm was found suitable for monitoring the separation of the entire mixture of PAR, CZ, and their impurities. Seven peaks eluted with excellent resolution at retention times 3.4, 5.7, 8.0, 10.1, 10.8, 13.5, and 14.4 min for AP, PAR, NP, AT, ACP, CZ, and CA, respectively. Performance of the proposed method was validated with respect to linearity, range, precision, accuracy, specificity, robustness, detection, and quantitation limits. Calibration curves were linear in the ranges of 10-75 and 10-100 µg/mL for PAR and CZ, respectively with correlation coefficients not less than 0.9998. The proposed method proved to be specific and stability indicating by the resolution of both drugs from their degradation products and toxic impurities. Validated HPLC method was successfully applied to the analysis of PAR and CZ in their combined capsules dosage form, and assay results were favorably compared with a published reference HPLC method. DAD served as an efficient tool for peak identity and purity verification.

Entities:  

Keywords:  HPLC-DAD; Paracetamol; chlorzoxazone; degradation products; impurities

Mesh:

Substances:

Year:  2020        PMID: 32894703     DOI: 10.1080/03639045.2020.1821054

Source DB:  PubMed          Journal:  Drug Dev Ind Pharm        ISSN: 0363-9045            Impact factor:   3.225


  1 in total

1.  Simple simultaneous determination of moxifloxacin and metronidazole in complex biological matrices.

Authors:  Amira F El-Yazbi; Faten M Aboukhalil; Essam F Khamis; Mohammed A W Elkhatib; Mahmoud A El-Sayed; Rasha M Youssef
Journal:  RSC Adv       Date:  2022-05-23       Impact factor: 4.036

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.