Literature DB >> 32894679

Development of an Aptamer-Based Lateral Flow Assay for the Detection of C-Reactive Protein Using Microarray Technology as a Prescreening Platform.

Ngoc Linh Phung1, Johanna G Walter1, Rebecca Jonczyk1, Lisa K Seiler1, Thomas Scheper1, Cornelia Blume1.   

Abstract

For improved cost-effectiveness and temperature-stability, a ready to use lateral flow assay (LFA) is developed in this work for detecting inflammation/infection biomarker C-reactive protein (CRP) in human patient samples on the basis of aptamers. In prescreening investigations, an aptamer with CRP affinity was immobilized on microarray chips in forward and sandwich formats to optimize assay conditions. We suggest these microarray techniques as a resource-sparing and fast-screening instrument for evaluation of various conditions. The capability of the aptamer to detect CRP was shown. Optimized assay conditions were consequently transferred to the LFA-platform. Here we could demonstrate for the first time an aptamer-based LFA for the detection of CRP in human patient samples in pathologically relevant concentrations. The cutoff for CRP detection is set at 10 mg/L, providing a distinctive "yes" (≥10 mg/L CRP) or "no" (<10 mg/L CRP) answer for the patient. The resulting aptamer-based LFA is promising with regard to its application as point-of-care testing (POCT) for efficient monitoring, especially of patients affected by frequent infections or inflammations.

Entities:  

Keywords:  CRP; POCT; aptamer-based LFA; aptamers; lateral flow assay; microarray

Year:  2020        PMID: 32894679     DOI: 10.1021/acscombsci.0c00080

Source DB:  PubMed          Journal:  ACS Comb Sci        ISSN: 2156-8944            Impact factor:   3.784


  3 in total

1.  Electrochemical aptasensor based on anisotropically modified (Janus-type) gold nanoparticles for determination of C-reactive protein.

Authors:  Anabel Villalonga; Alfredo Sánchez; Diana Vilela; Beatriz Mayol; Paloma Martínez-Ruíz; Reynaldo Villalonga
Journal:  Mikrochim Acta       Date:  2022-08-02       Impact factor: 6.408

2.  An Antibody-Aptamer-Hybrid Lateral Flow Assay for Detection of CXCL9 in Antibody-Mediated Rejection after Kidney Transplantation.

Authors:  Lisa K Seiler; Ngoc Linh Phung; Christoph Nikolin; Stephan Immenschuh; Christian Erck; Jessica Kaufeld; Hermann Haller; Christine S Falk; Rebecca Jonczyk; Patrick Lindner; Stefanie Thoms; Julia Siegl; Günter Mayer; Regina Feederle; Cornelia A Blume
Journal:  Diagnostics (Basel)       Date:  2022-01-25

Review 3.  Aptasensors versus immunosensors-Which will prevail?

Authors:  Sofia Arshavsky-Graham; Christopher Heuer; Xin Jiang; Ester Segal
Journal:  Eng Life Sci       Date:  2022-01-13       Impact factor: 2.678

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.