Literature DB >> 32892400

Development and validation of 3D MP-SSFP to enable MRI in inhomogeneous magnetic fields.

Naoharu Kobayashi1, Ben Parkinson2, Djaudat Idiyatullin1, Gregor Adriany1, Sebastian Theilenberg3, Christoph Juchem3,4, Michael Garwood1.   

Abstract

PURPOSE: We demonstrate the feasibility of MRI with missing-pulse steady-state free precession (MP-SSFP) in a 4T magnet with artificially degraded homogeneity.
METHODS: T1 , T2 , and diffusion contrast of MP-SSFP was simulated with constant and alternate radiofrequency (RF) phase using an extended phase graph. To validate MP-SSFP performance in human brain imaging, MP-SSFP was tested with two types of artificially introduced inhomogeneous magnetic fields: (1) a pure linear gradient field, and (2) a pseudo-linear gradient field introduced by mounting a head-gradient set at 36 cm from the magnet isocenter. Image distortion induced by the nonlinear inhomogeneous field was corrected using B0 mapping measured with MP-SSFP.
RESULTS: The maximum flip angle in MP-SSFP was limited to ≤10° because of the large range of resonance frequencies in the inhomogeneous magnetic fields tested in this study. Under this flip-angle limitation, MP-SSFP with constant RF phase provided advantages of higher signal-to-noise ratio and insensitivity to B1 + field inhomogeneity as compared with an alternate RF phase. In diffusion simulation, the steady-state magnetization in constant RF phase MP-SSFP increased with an increase of static field gradient up to 8 to 21 mT/m depending on simulation parameters. Experimental results at 4T validated these findings. In human brain imaging, MP-SSFP preserved sufficient signal intensities, but images showed severe image distortion from the pseudo-linear inhomogeneous field. However, following distortion correction, good-quality brain images were achieved.
CONCLUSION: MP-SSFP appears to be a feasible MRI technique for brain imaging in an inhomogeneous magnetic field.
© 2020 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  brain imaging; inhomogeneous magnetic field; missing pulse steady-state free precession

Mesh:

Year:  2020        PMID: 32892400      PMCID: PMC8132587          DOI: 10.1002/mrm.28469

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  37 in total

Review 1.  Principles and applications of balanced SSFP techniques.

Authors:  Klaus Scheffler; Stefan Lehnhardt
Journal:  Eur Radiol       Date:  2003-08-20       Impact factor: 5.315

2.  Low-gradient single-sided NMR sensor for one-shot profiling of human skin.

Authors:  Maxime Van Landeghem; Ernesto Danieli; Juan Perlo; Bernhard Blümich; Federico Casanova
Journal:  J Magn Reson       Date:  2011-12-28       Impact factor: 2.229

3.  Reconstruction of MRI data encoded with arbitrarily shaped, curvilinear, nonbijective magnetic fields.

Authors:  Gerrit Schultz; Peter Ullmann; Heinrich Lehr; Anna M Welz; Jürgen Hennig; Maxim Zaitsev
Journal:  Magn Reson Med       Date:  2010-09-16       Impact factor: 4.668

4.  Homogeneous tissue model estimates of RF power deposition in human NMR studies. Local elevations predicted in surface coil decoupling.

Authors:  P A Bottomley; P B Roemer
Journal:  Ann N Y Acad Sci       Date:  1992-03-31       Impact factor: 5.691

5.  Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedules and generation of clinical T2 contrast.

Authors:  Reed F Busse; Hari Hariharan; Anthony Vu; Jean H Brittain
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

6.  A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities.

Authors:  H Chang; J M Fitzpatrick
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

Review 7.  Steady-state MR imaging sequences: physics, classification, and clinical applications.

Authors:  Govind B Chavhan; Paul S Babyn; Bhavin G Jankharia; Hai-Ling M Cheng; Manohar M Shroff
Journal:  Radiographics       Date:  2008 Jul-Aug       Impact factor: 5.333

8.  Extended phase graphs: dephasing, RF pulses, and echoes - pure and simple.

Authors:  Matthias Weigel
Journal:  J Magn Reson Imaging       Date:  2014-04-16       Impact factor: 4.813

Review 9.  Gradient-echo MR imaging: techniques and acronyms.

Authors:  A D Elster
Journal:  Radiology       Date:  1993-01       Impact factor: 11.105

10.  Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo.

Authors:  William D Rooney; Glyn Johnson; Xin Li; Eric R Cohen; Seong-Gi Kim; Kamil Ugurbil; Charles S Springer
Journal:  Magn Reson Med       Date:  2007-02       Impact factor: 4.668

View more
  2 in total

1.  Contemporary approaches to high-field magnetic resonance imaging with large field inhomogeneity.

Authors:  Michael Mullen; Michael Garwood
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2020-08-16       Impact factor: 9.795

2.  Phase-based fast 3D high-resolution quantitative T2 MRI in 7 T human brain imaging.

Authors:  Amir Seginer; Rita Schmidt
Journal:  Sci Rep       Date:  2022-08-18       Impact factor: 4.996

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.