To the Editor: The use of contrast echocardiography in patients receiving venovenous extracorporeal membrane oxygenation (VV-ECMO) for severe acute respiratory failure is not widely published, and there is understandable caution surrounding its use in this population. The coronavirus disease 2019 pandemic resulted in an unprecedented burden on critical care facilities due to severe acute respiratory failure. Our center is one of five nationally commissioned VV-ECMO services in the United Kingdom and has seen VV-ECMO activity quadruple during the first pandemic surge. Consequently, there has been growing emphasis on transthoracic echocardiography (TTE) to diagnose cardiac complications of coronavirus disease 2019 supported with VV-ECMO. , Mechanically ventilated patients receiving VV-ECMO are among the most challenging in whom to obtain diagnostic images on TTE. Predictably, we found that as the volume of VV-ECMO patients increased, so too did the requirement for TTE using ultrasound-enhancing agents (UEAs). Contrast echocardiography is routinely used at our institution, and this work was approved through the local governance board as a service evaluation. We carried out bedside TTE in 37 consecutive VV-ECMO patients, among whom SonoVue (Bracco International, Milan, Italy) TTE was performed in 10 (27%). SonoVue boluses (0.5–0.7 mL), reconstituted in the standard format, were administered via the postoxygenator limb of the ECMO circuit. Repeated boluses of the UEA were required in all cases, with a maximum total dose in any one patient of 2.5 mL. All patients met criteria for the use of UEAs as outlined in the recently published guidance. Very low mechanical index imaging was performed with standard commercially available tissue cancelation sequences (Philips Medical Systems, Andover, MA). Very low mechanical index imaging allows excellent tissue delineation and results in less microbubble destruction than the higher mechanical index left ventricular opacification settings. Diagnostic images were obtained in all cases. In line with our institutional protocols for critical care echocardiography in extracorporeal support (developed in collaboration with our specialist perfusion team), during each contrast study, the VV-ECMO circuit was managed by experienced perfusionists. This included disabling the appropriate interventions on the ECMO console before UEA administration to ensure safe administration. UEAs are known to activate the protective integrated air bubble alarms, which trigger interventions to disable flow, a safety feature of the Cardiohelp ECLS system (MAQUET Medical Systems USA, Wayne, NJ,) and in all cases, the integrated detector for air bubbles was indeed triggered by the UEA. This would usually lead to a pump shutdown because of activation of additional safety interventions, and unless this alarm is cleared, a further “zero-flow mode” is engaged. This mode provides sufficient revolutions per minute to prevent backflow from the return cannula without providing forward flow, so equilibrium is maintained in the circuit. However, the resultant cessation of flow, and consequently oxygenation, can result in rapid desaturation and potentially hypoxic arrest. It is therefore of pressing importance that centers offering VV-ECMO adopt protocols and staff training to allow the safe administration of UEAs, facilitating diagnostic echocardiography in the most critical patients. To our knowledge, this is the largest published series affirming the applicability of a UEA in VV-ECMO. Appropriate protocols should be instituted at centers offering VV-ECMO, ensuring safe management of the circuit by the perfusion team. Enhanced echocardiography may therefore be an appropriate bedside technique during the current viral surge in critical VV-ECMO supported severe acute respiratory failure, helping address diagnostic uncertainty in cases with challenging echocardiographic visualization.
  3 in total

1.  Beware of life-threatening activation of air bubble detector during contrast echocardiography in patients on venoarterial extracorporeal membrane oxygenator support.

Authors:  Loreta Grecu; Michael A Fishman
Journal:  J Am Soc Echocardiogr       Date:  2014-07-30       Impact factor: 5.251

Review 2.  Clinical Applications of Ultrasonic Enhancing Agents in Echocardiography: 2018 American Society of Echocardiography Guidelines Update.

Authors:  Thomas R Porter; Sharon L Mulvagh; Sahar S Abdelmoneim; Harald Becher; J Todd Belcik; Michelle Bierig; Jonathan Choy; Nicola Gaibazzi; Linda D Gillam; Rajesh Janardhanan; Shelby Kutty; Howard Leong-Poi; Jonathan R Lindner; Michael L Main; Wilson Mathias; Margaret M Park; Roxy Senior; Flordeliza Villanueva
Journal:  J Am Soc Echocardiogr       Date:  2018-03       Impact factor: 5.251

Review 3.  ASE Statement on Protection of Patients and Echocardiography Service Providers During the 2019 Novel Coronavirus Outbreak: Endorsed by the American College of Cardiology.

Authors:  James N Kirkpatrick; Carol Mitchell; Cynthia Taub; Smadar Kort; Judy Hung; Madhav Swaminathan
Journal:  J Am Soc Echocardiogr       Date:  2020-04-03       Impact factor: 5.251

  3 in total
  2 in total

Review 1.  [Standardized contrast-enhanced ultrasound (CEUS) in clinical acute and emergency medicine and critical care (CEUS Acute) : Consensus statement of DGIIN, DIVI, DGINA, DGAI, DGK, ÖGUM, SGUM and DEGUM].

Authors:  Guido Michels; Rudolf Horn; Andreas Helfen; Andreas Hagendorff; Christian Jung; Beatrice Hoffmann; Natalie Jaspers; Horst Kinkel; Clemens-Alexander Greim; Fabian Knebel; Johann Bauersachs; Hans-Jörg Busch; Daniel Kiefl; Alexander O Spiel; Gernot Marx; Christoph F Dietrich
Journal:  Med Klin Intensivmed Notfmed       Date:  2022-02       Impact factor: 0.840

Review 2.  Advanced Echocardiography Techniques: The Future Stethoscope of Systemic Diseases.

Authors:  John Iskander; Peter Kelada; Lara Rashad; Doaa Massoud; Peter Afdal; Antoine Fakhry Abdelmassih
Journal:  Curr Probl Cardiol       Date:  2021-03-30       Impact factor: 16.464